PART 1
INSTALLATION
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
DO NOT ATTEMPT TO START THE BURNER
WHEN EXCESS OIL HAS ACCUMULATED, WHEN
THE FURNACE IS FULL OF VAPOR OR WHEN THE
COMBUSTION CHAMBER IS VERY HOT.
WARNING
For use with grade 2 Fuel Oil maximum. Do
Not use Gasoline, Crankcase Oil or any Oil
containing Gasoline!
CAUTION
Never burn garbage or paper in the heating
system and never leave rags or paper
around the unit.
CAUTION
These instructions are intended to be used
by qualified personnel who have been
trained in installing this type of furnace.
Installation of this furnace by an unqualified
person may lead to equipment damage
and/or hazardous condition, which may lead
to bodily harm.
Models cross-reference table
Models
AMP1-IE2
BMF-090
LBM090
AMP2-IE2
BMF-125
LBM120
1)
GENERAL
This furnace is a true multipositions unit, in that it may
be operated in all four positions when it use with
chimney, i.e., upflow, counterflow (downflow), and
horizontal (both left-to-right and right-to-left airflow).
Very few modifications are required to change the
furnace from one position to another at the job site.
The furnace is shipped in the upflow configuration-
instructions on changing to other configurations are on
this document.
It is shipped as a packaged unit, complete with burner
and controls. It requires a line voltage (115VAC)
connection to the control box, a thermostat hook-up as
shown on the wiring diagram, oil line connection (s),
adequate ductwork, and connection to a properly sized
vent.
IMPORTANT:
For sealed combustion system (SCS)
refer to the SCS-4 instruction manual. The appliance
must be installed in upflow position when used with a
SCS
IMPORTANT:
All local and national code
requirements governing the installation of oil burning
equipment, wiring and flue connections must be
followed. Some of the codes that may be applicable
are:
CSA B139
INSTALLATION CODE FOR OIL
BURNING EQUIPMENT
ANSI/NFPA 31
INSTALLATION OF OIL BURNING
EQUIPMENT
ANSI/NFPA 90B WARM AIR HEATING AND AIR
CONDITIONING SYSTEMS
ANSI/NFPA 211 CHIMNEYS, FIREPLACES, VENTS
AND SOLID FUEL BURNING
APPLIANCES
ANSI/NFPA 70
NATIONAL ELECTRICAL CODE
CSA C22.2 No.3 CANADIAN ELECTRICAL CODE
Only the latest issues of the above codes should be
used, and are available from either:
The National Fire Protection Agency
Batterymarch Park
Qunicy, MA 02269
or
The Canadian Standards Association
178 Rexdale Blvd.
Rexdale, Ontario M9W 1R3
The air handling capacity of this furnace is designed
for cooling airflow. Refer to table # 4 for the expected
airflow at various externals duct static pressures.
Содержание AMP1-IE2
Страница 20: ...FIGURE 6 1 Diagramme lectrique AMP1 IE2 LBM090 BMF 090 br leur Beckett 21 DNS 0635 R v A...
Страница 21: ...FIGURE 6 2 Diagramme lectrique AMP2 IE2 LBM120 BMF 125 br leur Beckett 22 DNS 0636 R v A...
Страница 22: ...FIGURE 6 3 Diagramme lectrique AMP1 IE2 LBM090 BMF 090 br leur Riello 23 DNS 0633 R v A...
Страница 23: ...FIGURE 6 4 Diagramme lectrique AMP2 IE2 LBM120 BMF 125 br leur Riello 24 DNS 0634 R v A...
Страница 26: ...FIGURE 6 7 Diagramme lectrique AMP1 IE2 LBM090 BMF 090 br leur B SCS 27 DNS 0643 R v A...
Страница 27: ...FIGURE 6 8 Diagramme lectrique AMP2 IE2 LBM120 BMF 125 br leur B SCS DNS 0644 R v A 28...
Страница 50: ...19 FIGURE 6 1 Wiring diagram AMP1 IE2 LBM090 BMF 090 Beckett burner DNS 0488 Rev B...
Страница 51: ...20 FIGURE 6 2 Wiring diagram AMP2 IE2 LBM120 BMF 125 Beckett burner DNS 0489 Rev B...
Страница 52: ...21 FIGURE 6 3 Wiring diagram AMP1 IE2 LBM090 BMF 090 Riello burner DNS 0405 Rev B...
Страница 53: ...22 FIGURE 6 4 Wiring diagram AMP2 IE2 LBM120 BMF 125 Riello burner DNS 0406 Rev B...
Страница 56: ...FIGURE 6 7 Wiring diagram AMP1 IE2 LBM090 BMF 090 B SCS burner 25 DNS 0641 Rev A...
Страница 57: ...FIGURE 6 8 Wiring diagram AMP2 IE2 LBM120 BMF 125 B SCS burner 26 DNS 0642 Rev A...
Страница 58: ...PARTS LIST Model AMP1 IE2 LBM090 BMF 090 27 Serial number higher than 172980 or S0598V04041 DNS 0187 Rev F...
Страница 60: ...PARTS LIST Model AMP2 IE2 LBM120 BMF 125 29 Serial number higher than 173130 or S0698V04191 DNS 0348 Rev F...