Part Number
Issue
Date
Page
6159937790
12
03/2018
87 / 184
87 (184)
03/2018
For
Residual torque
strategies, the
Abort Cycle Time
is the only timeout available in the test strategy;
for
Residual Torque/Angle
and
Residual Torque/Angle Automatic
, when the residual torque is
detected the test ends even if the timeout has not expired.
6.5
Batch Parameters
Batch count
Enable this flag to execute the Pset more than once.
Batch size
If
Batch count
is enabled, it specifies how many times the Pset must be
executed.
Maximum value: 99
NOTE
: If the
Batch count
is disabled, the
Batch status
in the
tightening results is always OK.
By enabling the
Batch count
and setting the
Batch size
to 1, it is
possible to have the
Batch result
OK only if the Pset gives result OK.
If the
Batch size
is greater than 1, the
Batch result
is OK only if all of
the Pset give result OK.
Cycle start
Target torque
Abort cycle time End cycle time
Time
Time
Torque
The test ends when
the torque remains
below the
Cycle
Start
for more than
the timeout
Before the torque
reaches the
Target
Torque
, the
Abort Cycle
Time
is applied
After the torque
reaches the
Target Torque
,
the
End Cycle
Time
is applied