EN
Operation
06/2020
11 / 28
Go to
Enter password
, then
Pset password
, use the buttons to display "1", save and and validate. The red padlock
turns green.
The procedure is the same to disable the Maintenance password.
How to set up new passwords
To set new passwords, current passwords must be disabled and the green padlock displayed.
Go to the main screen.
Press this button during 2 seconds.
Press this button to reach
Configuration
.
Go to
Set password
, then
Pset password
, use the buttons to enter a figure from 0 to 999, save and validate.
Setting the password to 0 will disable all password protections.
The procedure is the same to set up a new Maintenance password.
Sound, torque unit
Sound
The tool can emit sounds to alert the operator in case of problems or events that may happen during the tightening
operation.
Sounds can be set for the following topics:
• tightening out of tolerances
• calibration procedure
• preventive maintenance
• low battery
• hardware failure
• maintenance
On tool delivery, the sound is disabled.
To enable the sound, go to the main screen.
Press this button during 2 seconds.
Press this button to reach
Configuration
.
Go to
Sound
, then No sound, use the buttons to save and validate.
Torque unit
The following torque units are available:
• Nm
• ft.lb
• in.lb
• kg.m
• kg.cm
• oz.in
• dNm
To change the torque unit, go to the main screen.