DISMANTLING THE PUMP SET
DESMI Pumping Technology A/S
Tagholm 1
9400 Nørresundby
– Denmark
Tlf. nr.: +45 96 32 81 11
Fax +45 98 17 54 99
E-mail: [email protected]m
82
3. Dismantle pipe (58).
4. Remove set screws (22) with washers (23),
which hold the rear cover (18) to the pump
casing.
5. Loosen the rear cover from the pump casing by
means of the pointed screws (86). The motor
and motor bracket with rear cover and shaft with
impeller can now be lifted up allowing inspection
of the impeller.