![Desmi NSL 100-215 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/desmi/nsl-100-215/nsl-100-215_operation-and-maintenance-instruction_2487038076.webp)
INSPECTION AND SERVICE PLAN
DESMI Pumping Technology A/S
Tagholm 1
9400 Nørresundby
– Denmark
Tlf. nr.: +45 96 32 81 11
Fax +45 98 17 54 99
E-mail: [email protected]m
74
.
DANGER
FIRE AND EXPLOSION HAZARD!
Too high temperature caused by friction, impact or frictional sparks can cause fire, and if
not avoided, will lead to death or serious injury.
Regularly check the coupling guard regarding screws being tightened and/or regarding
deformation for ensuring sufficient distance from rotating parts.
8.2.1. Cleaning filter
.
CAUTION
RISK OF PROPERTY DAMAGE!
Incorrect inlet pressure due to clogged filter in the suction line could damage the pump.
Monitor contamination of filter with suitable instruments (for example, using differential
pressure gauge).
Clean the filter at appropriate intervals.
8.2.2. Drainage and cleaning
.
WARNING
ENVIRONMENTAL HAZARD!
Hot fluids, consumables and supplies are hazardous to health and to the environment.
Collect and properly dispose of flushing fluid and any residues of the fluid handled.
Wear safety clothing and a protective mask.
Dispose of all fluids in accordance with local regulations.
1. Drain the fluid handled by dismantling the pipe plug (3) at the bottom of the pump.
2. Always flush the system if it has been used for handling noxious, explosive, hot or other
hazardous fluids.
3. Always flush and clean the pump before transporting it to the workshop.
4. Provide a certificate of decontamination for the pump.
Содержание NSL 100-215
Страница 2: ......