10.2. 02, 13 and 14 combinations
10.2.1. Fitting sealing rings
1. When fitted, the sealing ring (4) in the pump
casing (1) is to bear against the shoulder of the
pump casing.
For Ø330/415/418/465/525,
when fitted, the sealing
ring (27) in the rear cover is to bear against the
shoulder of the rear cover.
For Ø418, secure the sealing ring (27) with counter
sunk screws.
For NSL350-525, secure the sealing ring (27) and
Guard plate (38) with Counter sunk screw (39).