Desmi NSL 100-215 Скачать руководство пользователя страница 1

 

 

DESMI Vertical In-Line Centrifugal Pump 

OPERATION AND MAINTENANCE INSTRUCTIONS 

NSL MONOBLOC & SPACER

 

     

     

 

 

     

 

DESMI Pumping Technology A/S

 

Tagholm l, DK-9400 Nørresundby, Denmark 

 

      Tel.:  +45 96 32 81 11 

 

Fax:  +45 98 17 54 99 

 

E-mail: 

[email protected]

 

 

Internet: 

www.desmi.com

   

 

Manual: 

T1542  

Language: 

English  

Revision: 

A.1  

 

 

Special pump Number. ...............................................  

Original instructions 

Содержание NSL 100-215

Страница 1: ...NSTRUCTIONS NSL MONOBLOC SPACER DESMI Pumping Technology A S Tagholm l DK 9400 N rresundby Denmark Tel 45 96 32 81 11 Fax 45 98 17 54 99 E mail desmi desmi com Internet www desmi com Manual T1542 Lang...

Страница 2: ......

Страница 3: ...he product 11 2 2 Intended use 12 2 3 Consequences and risks caused by non compliance with this manual 13 2 4 Safety awareness 13 2 5 Safety information for the operator user 13 2 6 Safety information...

Страница 4: ...combination 33 4 4 5 NSL 330 415 418 465 525 12 combination 35 4 4 6 NSL 330 415 418 465 525 13 14 combinations 37 4 5 Pump weight 39 5 INSTALLATION 41 5 1 Mounting Fastening 41 5 2 Wiring 41 6 COMMIS...

Страница 5: ...ET 95 10 1 12 combination 95 10 1 1 Fitting sealing rings 95 10 1 2 Fitting shaft seal 96 10 1 3 Fitting impeller 97 10 1 4 Fitting rear cover or motor bracket 99 10 1 5 Shaft 100 10 2 02 13 and 14 co...

Страница 6: ...50 300 525 12 combination 131 11 18 Spare parts list NSL200 250 300 525 12 combination 132 11 19 Assembly drawing NSL350 525 02 combination 133 11 20 Spare parts list NSL350 525 02 combination 134 11...

Страница 7: ...shaft with or without ball bearing mounted on it is coupled with electric motor shaft either by rigid coupling or by flexible coupling The pump suction and discharge ports are casted flanges which com...

Страница 8: ...Information attached directly to the pump must always be complied with and be kept in a perfectly legible condition at all times This applies to for example Arrow indicating the direction of rotation...

Страница 9: ...requirements Procedure for hydrostatic testing EN 60204 1 2006 A1 2009 Safety of machinery Electrical equipment of machines item 4 General requirements Ecodesign Directive 2009 125 EC Water pumps Com...

Страница 10: ...w The liquid in the pump also serves as coolant for the shaft seal Dry run will result in frictional heat being developed causing critical high temperatures at seal faces NOTE Pumping against closed o...

Страница 11: ...rive power 10 C above normal operating temperature Contact DESMI in case of doubt about max allowed liquid temperature N rresundby August 25 2022 Henrik M rkholt S rensen Managing Director DESMI Pumpi...

Страница 12: ...ndicates a hazard with a low level of risk which if not avoided could result in damage to the product or system Information with this heading is used to address practices not related to personal injur...

Страница 13: ...S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 11 E mail desmi desmi com www desmi com 2 1 3 Labels on the product The diagrams below indicate the location of the machin...

Страница 14: ...specified in the product literature to prevent overheating bearing damage etc Observe the information on maximum flow rates specified in the product literature to prevent overheating mechanical seal...

Страница 15: ...lations shall be complied with Accident prevention health and safety regulations Explosion protection regulations Safety regulations for handling hazardous substances Applicable standards directives a...

Страница 16: ...ed re install and or re activate any safety relevant and protective devices Before returning the product to service observe all instructions on commissioning 2 7 Unauthorised modes of operation Never...

Страница 17: ...for fresh water and most likely less for other liquids If the pump is to be operated at a higher temperature or if the pump is part of a pool of pumps contact DESMI for the maximum permissible operat...

Страница 18: ...8 17 54 99 E mail desmi desmi com www desmi com 16 2 9 Frost protection Pumps which are not in operation during frost periods are to be drained to avoid frost damage Remove the plug 3 at the bottom to...

Страница 19: ...th or serious injury Always transport the pump set in the specified position Do not attach the suspension arrangement to the free shaft end or the motor eyebolt Monitor the weight data and the centre...

Страница 20: ...TORAGE DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 E mail desmi desmi com www desmi com 18 Figure 3 1 Transport NOTE The lifting straps mus...

Страница 21: ...e pump into storage clean and cover the pump openings and connections as needed Store the pump set in a dry protected room where the atmospheric humidity is as constant as possible Rotate the shaft by...

Страница 22: ...al of fluids posing a health hazard Collect and properly dispose of flushing fluid and any residues of the fluid handled Handle the chemicals and machine components according to instructions and local...

Страница 23: ...ex pumps with special shaft seal The pump is suitable for pumping of clean fresh water with temperatures up to 100 C when ball bearing mounted on pump shaft and up to 140 C when without ball bearing m...

Страница 24: ...ion Maximum inlet pressure Pump maximum working pressure pump shut head It is the pressure that shall not lead pump outlet pressure to excess pump allowed maximum working pressure in specific pump ope...

Страница 25: ...more torque from pump shaft and more mechanical power from the electric motor This could cause overloading of the pump shaft and the motor Contact your supplier for advice if needed The permissible l...

Страница 26: ...served 2 2 2 Where index calc is the valves calculated by the user At the same time none of the forces or moments may exceed the indicated figure multiplied by 1 4 4 2 Technical data 4 2 1 Maximum wor...

Страница 27: ...pressure for bronze RG5 CC491K The above mentioned max working pressure is a design value delivered pumps are pressure tested according to actual application requirements or actual flange standards F...

Страница 28: ...es e g rotation speed duty point shift by external force liquid type etc Figure 4 2 Vibration measuring position 4 2 4 Hydraulic capacity The capacity of flow and head of the pump is stated on the nam...

Страница 29: ...re provided with a name plate on body to describe pump hydraulic and mechanical specification Individual motor name plate on motor body of which description is given in motor operation manual Figure 4...

Страница 30: ...he pumps can be delivered in other material combinations according to agreement with the supplier R may be the following 02 Monobloc with bearing in the pump 12 Monobloc without bearing in the pump 13...

Страница 31: ...f pump performance M3 HOUR TOTAL HEAD M is rated flow and corresponding total head which is achievable by the pump by verification or by test on mutual agreement If test is performed ISO9906 Grade 2B...

Страница 32: ...2 BSP Type H h1 h2 L L1 W DN D d2 K X Y Z B B1 As NSL80 215 567 200 155 530 265 163 80 200 18 160 20 306 25 350 175 8 NSL80 265 574 200 155 580 290 193 80 200 18 160 20 306 25 350 175 8 NSL100 215 587...

Страница 33: ...5 530 265 163 80 200 18 160 20 306 25 405 175 NSL80 265 450 200 155 580 290 193 80 200 18 160 20 306 25 405 175 NSL100 215 465 200 155 580 290 181 100 220 18 180 20 306 25 405 175 NSL100 265 470 200 1...

Страница 34: ...200 155 580 290 193 80 200 18 160 20 306 25 405 175 8 NSL100 215 889 200 155 580 290 181 100 220 18 180 20 306 25 405 175 8 NSL100 265 920 200 155 630 315 193 100 220 18 180 20 306 25 405 175 8 NSL12...

Страница 35: ...600 300 250 235 200 220 200 100 80 180 160 NSL100 330 743 260 215 650 325 250 270 235 250 220 125 100 210 180 NSL100 415 761 260 215 700 350 275 270 235 250 220 125 100 210 180 NSL125 330 788 300 255...

Страница 36: ...300 460 400 NSL350 525 1195 430 390 1400 700 453 565 505 580 520 400 350 515 460 Type d2s d2d As Ad X Y Z B B1 O NSL80 330 18 18 8 8 20 306 25 405 175 200 NSL100 330 18 18 8 8 20 306 25 405 175 210 N...

Страница 37: ...650 325 250 270 235 250 220 125 100 210 180 NSL100 415 547 260 215 700 350 275 270 235 250 220 125 100 210 180 NSL125 330 549 300 255 700 350 250 300 270 285 250 150 125 240 210 NSL125 415 585 300 255...

Страница 38: ...350 515 460 Type d2s d2d As Ad X Y Z B B1 O NSL80 330 18 18 8 8 20 306 25 405 175 200 NSL100 330 18 18 8 8 20 306 25 405 175 210 NSL100 415 18 18 8 8 20 450 25 550 250 250 NSL125 330 22 18 8 8 20 306...

Страница 39: ...650 325 250 270 235 250 220 125 100 210 180 NSL100 415 1107 260 215 700 350 275 270 235 250 220 125 100 210 180 NSL125 330 1130 300 255 700 350 250 300 270 285 250 150 125 240 210 NSL125 415 1145 300...

Страница 40: ...00 350 515 460 Type d2s d2d As Ad X Y Z B B1 O NSL80 330 18 18 8 8 20 306 25 405 175 200 NSL100 330 18 18 8 8 20 306 25 405 175 210 NSL100 415 18 18 8 8 20 450 25 550 250 250 NSL125 330 22 18 8 8 20 3...

Страница 41: ...comb KG Pump A02 A12 D02 D12 comb KG NSL80 215 126 141 100 NSL150 415 454 474 404 424 NSL80 265 135 152 109 NSL200 265 207 240 181 NSL80 330 256 261 206 211 NSL200 330 409 394 359 344 NSL100 215 137 1...

Страница 42: ...80 330 301 301 306 306 NSL200 330 459 444 NSL100 215 197 197 214 214 NSL200 415 579 599 NSL100 265 196 196 213 213 NSL200 525 829 919 NSL100 330 311 311 317 317 NSL250 265 346 386 NSL100 415 404 404 4...

Страница 43: ...ate corner and foundation then insert shim s at least 50x50 mm between pump base plate corner and foundation before tightening the four bolts in the pump base plate corners The max permissible loads o...

Страница 44: ...thumb ensures laminar flow before and after the pump that will give optimum operating conditions But in practice there are many installations where this is not obtained X minimum length of suction pi...

Страница 45: ...kets Pipes shall be connected correctly and not overloading the pump flanges Refer to chapter 4 1 regarding max permissible loads on the pump flanges Pipe support shall be designed according to the pi...

Страница 46: ...pipeline Flow velocity v in following ranges Note Higher velocities might be acceptable in some installations and or for short term operation v 3 m s at inlet side note v 1 5 m s in manifolds splitti...

Страница 47: ...e recommendations in the international standard ISO10816 3 Vibration prevention on vertical Pumps installed on ships High vibration levels at pump motor top is a well known issue in vertical pumps ins...

Страница 48: ...0 or 3570 rpm it is normally better to mount the lateral supports at the motor s lifting eye bolt holes i e near the center of gravity for the motor Examples of DESMI vertical pumps with lateral suppo...

Страница 49: ...f not the pump will not work normally and might be damaged due to cavitation and or deliver less flow and or less differential pressure H Hb NPSHr Hf Hv Hs Here Hb Barometric liquid head m Pb 10 2 SG...

Страница 50: ...am is required Note Some pumps have a service area underneath Insulation Pumps supplied by DESMI can not generally be insulated for heat except at the top of the pump housing i e up to the base flange...

Страница 51: ...lines so that The pump is efficiently ventilated The room temperature not exceeding 45 C Ensure airflow around the pump motor The rating of the electrical apparatus is critical in this respect Operati...

Страница 52: ...checked All auxiliary connections required are connected and operational If re greasable then motor bearings to be greased acc to motor manual before starting the pump Any pump bearing s are fully gr...

Страница 53: ...Vent the pump and the suction line and prime both with the fluid to be handled 2 Fully open the shut off element in the suction line 3 Fully open all auxiliary feed lines barrier fluid flushing liqui...

Страница 54: ...esundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 E mail desmi desmi com www desmi com 52 Figure 6 1 Priming pump B114N Figure 6 2 Priming air ejector Please see manual for more details http ww...

Страница 55: ...dry running or too much gas content in the fluid handled will cause death or serious injury Do not operate the pump set without liquid fill Prime the pump according to operating instructions Always op...

Страница 56: ...nd or the shaft seal In pressurized systems the shaft seal often leaks a bit during standstill in most cases the leakage stops shortly after the pump is started up It is not recommended to lead liquid...

Страница 57: ...ut off element in the discharge line and adjust it to comply with the duty point 6 4 Checking the shaft seal The mechanical seal only leaks slightly or invisibly as vapor during operation Mechanical s...

Страница 58: ...hapter 4 2 to be complyed with DANGER EXPLOSION HAZARD LEAKAGE OF HOT OR TOXIC FLUID HANDLED When you operate the pump incorrect pressure temperature fluid handled and speed will cause damage to prope...

Страница 59: ...n the power reserves of the motor in steady state operation and on the starting conditions DOL star delta moments of inertia etc If the start ups are evenly spaced over the period indicated the follow...

Страница 60: ...e to be expected In this case reduce the commonly recommended inspection intervals 6 9 Decommissioning out of service When the pump is decommissioned or put out of service for a longer period of time...

Страница 61: ...w alloy materials Commercially available preservatives can be used for this purpose Observe the manufacturer s instructions for application removal Observe any additional instructions and information...

Страница 62: ...ng of the differential pressure the quantity of water delivered can be determined against the characteristics of the pump If the pump does not function as intended please proceed according to the faul...

Страница 63: ...Ensure correct storage of pumps 2 Preventive maintenance to be followed for long term storage 3 Rotate pump carefully by hand prior to first start up to ensure integrity of mech shaft seal Pump settle...

Страница 64: ...ations in the pump and unstable operational readings 2 Flow not increasing at higher pump speed 3 Possible leaking mechanical seal 1 Make sure all valves are open and no filters are clogged etc 2 Chec...

Страница 65: ...ystems are working and or with closed suction valves 2 Can operate for a short time towards shut discharge valve acc to rec in manual Operating outside recommended QH area 70 120 of BEP Can lead to pr...

Страница 66: ...ve sufficient ramp down time and avoid closing valves too fast 2 Correct usage of non return valves Pump parts e g vent flush piping in pump clogged up Missing supply of liquid for cooling lubrication...

Страница 67: ...is considered a wear and tear part A mechanical seal might have some initial leakage like drops or a small trickle during first start up as it has not yet fully settled and become tight Observe the me...

Страница 68: ...h the fluid to be handled at all times Provide sufficient inlet pressure Provide an appropriate monitoring system DANGER EXPLOSION HAZARD LEAKAGE OF HOT OR HAZARD FLUIDS DAMAGE TO THE PUMP SET RISK OF...

Страница 69: ...not close the shut off element in the suction line and or supply line during pump operation CAUTION RISK OF PROPERTY DAMAGE Too high temperature of fluid handled could damage the pump Do not operate t...

Страница 70: ...n when handling the liquid CAUTION RISK OF PROPERTY DAMAGE Operation of the pump at incorrect bearing temperature could damage the pump Make sure that the bearing temperature of the pump set is not mo...

Страница 71: ...aft seal replacement is recommended I Motor ampere and or power consumption within normal range I Unusual noise I Unusual vibration normally less than 2 8 mm s from pump itself and less than 7 mm s in...

Страница 72: ...able The bearing is to be replaced in case of noise or bearing wear Pump 330 415 418 465 525 Light bearing housing single row ball bearing The bearing is to be relubricated through the lubricator nipp...

Страница 73: ...ble for ideal greasing and operating conditions life of 100 000 working hours and are to be relubricated according to the table below Pump 215 265 330 415 418 465 525 Light bearing housing 13 combinat...

Страница 74: ...bricator nipples 84 at top and bottom of the bearing housing 18 See instructions for 215 265 The top bearing 15 is to be mounted with the RS sealing facing downwards fill the bearing itself with greas...

Страница 75: ...Rembrandt EP 2 or Rubens Statoil UniWay Li 62 If the pump liquid temperature is above 80 C high temperature grease is recommended e g SKF LGHP2 DESMI use SKF LGHP2 as standard Vibration levels higher...

Страница 76: ...could damage the pump Monitor contamination of filter with suitable instruments for example using differential pressure gauge Clean the filter at appropriate intervals 8 2 2 Drainage and cleaning WAR...

Страница 77: ...w the instructions Use appropriate personal protective equipment depending on the task WARNING HOT SURFACE HAZARD Touching any part of a hot pump can cause severe injury Always allow the pump set to c...

Страница 78: ...n the individual components may be hard to pull off the shaft If this is the case use a brand name penetrating agnet and or if possible an appropriate puller Preparing the pump set 1 De energise the p...

Страница 79: ...ipping over Note On NSL 12 design pumps the motor motor bracket rear cover and shaft with impeller shall be lifted away from the pump casing as one assembled unit Remove the back pull out unit WARNING...

Страница 80: ...E mail desmi desmi com www desmi com 78 2 Remove Allen screws 22 which hold the rear cover 18 and the motor bracket 20 to the pump casing 1 3 Dismantle pipe 58 4 Remove motor bracket and motor The rea...

Страница 81: ...mi com www desmi com 2 Remove Allen screws 22 which hold the motor bracket 20 to the pump casing 1 stainless steel pumps have separate rear cover 18 and motor bracket 20 and use Allen screw 40 to conn...

Страница 82: ...r 45 96 32 81 11 Fax 45 98 17 54 99 E mail desmi desmi com www desmi com 80 2 Remove set screws 64 which hold the motor bracket 20 to the pump casing 1 3 Dismantle pipe 58 4 Remove motor bracket and m...

Страница 83: ...il desmi desmi com www desmi com 6 Loosen the rear cover from the pump casing by means of the pointed screws 86 The rear cover with shaft and impeller can now be lifted up allowing inspection of the i...

Страница 84: ...mi desmi com www desmi com 82 3 Dismantle pipe 58 4 Remove set screws 22 with washers 23 which hold the rear cover 18 to the pump casing 5 Loosen the rear cover from the pump casing by means of the po...

Страница 85: ...f nr 45 96 32 81 11 Fax 45 98 17 54 99 83 E mail desmi desmi com www desmi com 9 1 2 Dismantling shaft seal 215 265 02 combination 1 Pull the rear cover off the motor bracket by which the coupling 19...

Страница 86: ...ews 16 which hold the bearing cover 15 to the rear cover pull rear cover and bearing cover apart by which shaft seal 10 and water deflector 11 are pulled off the shaft 215 265 12 combination 1 Remove...

Страница 87: ...330 415 418 465 525 02 combination 1 Remove set screw 6 Pull off the impeller 5 and remove sunk key 9 2 Remove set screws 16 which hold the bearing cover 15 to the rear cover pull rear cover and bear...

Страница 88: ...cover out of motor bracket by which the shaft seal 10 is pulled off the shaft 9 1 3 Dismantling seat 1 Press out the seat from behind the rear cover or motor bracket 215 265 in 12 combination 9 1 4 Di...

Страница 89: ...to remove the coupling in the 02 combination or the shaft in the 12 combination during normal maintenance However in the 12 combination the shaft must be removed when the lower bearing in the electri...

Страница 90: ...eller The numbers in brackets refer to the position numbers on the assembly drawing 215 265 1 Dismantle guard 69 2 Remove Allen screws 77 between coupling part motor 71 and spacer 72 and the screws 76...

Страница 91: ...oosen the pointed screw 73 and pull the coupling part pump 70 off the shaft 4 Dismantle the pipe 58 5 Remove Allen screws 22 which hold the rear cover 20 to the pump casing Remove the rear cover from...

Страница 92: ...ology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 E mail desmi desmi com www desmi com 90 330 415 418 465 525 1 Dismantle guard 69 2 Remove Allen screws 76 at each...

Страница 93: ...d pull the coupling part pump 70 off the shaft 4 Dismantle the pipe 58 5 Remove set screws 22 with washers 23 which hold the rear cover to the pump casing Remove the rear cover from the pump casing by...

Страница 94: ...desmi com 92 215 265 1 Remove nut 6 Pull off the impeller and remove sunk key 9 2 Remove Allen screws 19 which hold the bearing housing to the rear cover pull rear cover and bearing housing apart by...

Страница 95: ...0 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 93 E mail desmi desmi com www desmi com 2 Remove set screws 19 which hold the bearing housing to the rear cover pull rear cover and beari...

Страница 96: ...arings 1 Before dismantling the shaft with bearings remove the sunk key 16 The shaft can now be pulled out of the bearing housing allowing inspection of the bearings 9 2 5 Inspection When the pump has...

Страница 97: ...cessories used during assembling work including oil and grease shall meet the the requirement from application food approved if required 10 1 12 combination 10 1 1 Fitting sealing rings 1 When fitted...

Страница 98: ...e lapped surface and lubricate the outer rubber L ring of the seat with a thin layer of silicone grease Use a brush and ensure that no silicone grease ends up at the slide surface 3 Press the seat int...

Страница 99: ...with shaft NOTE Push the slide ring over the shaft with the hand If the rubber bellows is tight use a fitting tool and take care that the slide ring is not damaged If the carbon ring is not fixed it...

Страница 100: ...5 525 fix the rear cover to the motor bracket mounted with electric motor Assembly the shaft seal 10 4 Fit the sunk key in the shaft and lead the impeller towards the shoulder of the shaft Secure the...

Страница 101: ...www desmi com 10 1 4 Fitting rear cover or motor bracket 1 Place the O ring 21 between pump casing and rear cover or motor bracket in 215 265 in the O ring groove and hold it with a little grease 2 Sc...

Страница 102: ...ddle screw according to the below table Check that the wobble measured as close to the shaft end as possible is within the limits indicated in the table Motor size Dimension Pointed screws Torque Poin...

Страница 103: ...1 Fitting sealing rings 1 When fitted the sealing ring 4 in the pump casing 1 is to bear against the shoulder of the pump casing For 330 415 418 465 525 when fitted the sealing ring 27 in the rear co...

Страница 104: ...t disc 14 grease valve ring in 330 415 418 525 with angular ball bearings in the bearing cover and press the bearing into place in the bearing cover Lead the shaft 17 through the bearing cover support...

Страница 105: ...418 465 525 For pumps with Lip seal in cover under bearing please read appendix A 10 2 3 Fitting water deflector 215 265 1 Assemble bearing cover and rear cover 2 Lead the water deflector 11 over the...

Страница 106: ...over and rear cover Do not fasten bearing cover and electric motor until the motor has been mounted and the shaft can rotate freely without 10 2 4 Fitting shaft seal For pumps with balanced shaft seal...

Страница 107: ...g bush as shown on the assembly drawing is recommended to avoid that the rubber bellows is cut NOTE Push the slide ring over the shaft with the hand If the rubber bellows is tight use a fitting tool a...

Страница 108: ...nk key in the shaft and lead the impeller towards the shoulder of the shaft Secure the impeller with washers 7 and 8 and a set screw 10 2 6 Fitting bearing housing and rear cover 1 Place the O ring 21...

Страница 109: ...rews 86 back into the rear cover 3 Fit and fasten bearing housing and rear cover in the pump casing 10 2 7 Shaft When the pump has been assembled check that the shaft rotates freely NOTE When placing...

Страница 110: ...81 11 Fax 45 98 17 54 99 E mail desmi desmi com www desmi com 108 10 2 8 Fitting coupling In 02 combination 1 Fit sunk key 76 2 When the coupling bears against the shoulder of the pump shaft fit the...

Страница 111: ...ews 76 which are tightened up with torque according to the table below 2 Secure the coupling part pump 70 to the shaft by means of the pointed screw 73 NOTE If the coupling is fitted on the assembled...

Страница 112: ...ng to the coupling part motor 71 by means of the Allen screws 77 and lock nuts 79 also with torque according to the table below In order to secure the bolt connection fit a new lock nut or secure with...

Страница 113: ...of benzene 3 Place coupling bushes 74 in the top holes of the spacer 72 the chamfering on the bushes is to face downwards Place the coupling bush in the bottom holes of the spacer the chamfering on th...

Страница 114: ...allow dismantling and tighten all screws with the torque wrench It might be necessary to push the spacer a little until the screws have located in the thread and you feel that the spacer has found th...

Страница 115: ...SPK can be ordered via spareparts desmi com Recommended spare parts stock for 2 years operation to DIN 24296 Quantity of spare parts for recommended spare parts stock NSL 02 combination Part No Descri...

Страница 116: ...25 4 Casing wear ring 2 2 2 3 3 4 50 27 only for 330 415 418 465 525 Rear cover wear ring 2 2 2 3 3 4 50 SPK 2 2 2 3 3 4 50 NSL 13 14 combinations Part No Description Number of pumps including stand...

Страница 117: ...SPARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 115 E mail desmi desmi com www desmi com 11 1 Assembly drawing NSL 215 265 02 comb...

Страница 118: ...crew 3 Pipe plug 28 Guard 4 Sealing ring 58 Pipe 5 Impeller 59 Hexagon nipple 6 Nut 70 Allen screw 7 Spring washer 71 Set screw 8 Washer 72 Intermediate flange 9 Sunk key 73 Pointed screw 10 Shaft sea...

Страница 119: ...SPARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 117 E mail desmi desmi com www desmi com 11 3 Assembly drawing NSL 215 265 12 comb...

Страница 120: ...Description 1 Pump casing 28 Guard 2 Pipe plug 58 Pipe 3 Pipe plug 59 Hexagon nipple 4 Sealing ring 71 Set screw 5 Impeller 73 Pointed screw 6 Nut 75 INSEX screw 7 Spring washer 81 Sealing washer 8 W...

Страница 121: ...SPARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 119 E mail desmi desmi com www desmi com 11 5 Assembly drawing NSL 215 265 S12 com...

Страница 122: ...casing 40 Allen screw 2 Pipe plug 58 Pipe 3 Pipe plug 59 Hexagon nipple 4 Sealing ring 70 Allen screw 5 Impeller 71 Set screw 6 Nut 72 Interm flange 7 Spring washer 73 Pointed screw 8 Washer 75 INSEX...

Страница 123: ...PARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 121 E mail desmi desmi com www desmi com 11 7 Assembly drawing NSL 330 415 465 02 co...

Страница 124: ...ple 6 Set screw 64 Set screw 7 Spring washer 70 Allen screw 8 Washer 71 Set screw 9 Sunk key 72 Intermediate flange 10 Mech Shaft seal 73 Pointed screw 11 Water deflector 75 INSEX screw 12 Ring lock 7...

Страница 125: ...PARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 123 E mail desmi desmi com www desmi com 11 9 Assembly drawing NSL 330 415 465 12 co...

Страница 126: ...1 Pump casing 28 Guard 2 Pipe plug 58 Pipe 3 Pipe plug 59 Hexagon nipple 4 Sealing ring 64 Set screw 5 Impeller 71 Set screw 6 Set screw 73 Pointed screw 7 Spring washer 75 INSEX screw 8 Washer 81 Sea...

Страница 127: ...SPARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 125 E mail desmi desmi com www desmi com 11 11 Assembly drawing NSL300 418 02 comb...

Страница 128: ...ipple 6 Nut 64 Set screw 7 Spring washer 70 Allen screw 8 Inlet cone 71 Set screw 9 Sunk key 72 Intermediate flange 10 Mech shaft seal 73 Pointed screw 11 Water deflector 75 INSEX screw 12 Ring lock 7...

Страница 129: ...SPARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 127 E mail desmi desmi com www desmi com 11 13 Assembly drawing NSL300 418 12 comb...

Страница 130: ...pe plug 59 Hexagon nipple 3 Pipe plug 61 Hexagon nipple 4 Sealing ring 64 Set screw 5 Impeller 71 Set screw 6 Nut 73 Pointed screw 7 Spring washer 75 INSEX screw 8 Inlet cone 81 Sealing washer 9 Sunk...

Страница 131: ...RE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 129 E mail desmi desmi com www desmi com 11 15 Assembly drawing NSL200 250 300 525 02...

Страница 132: ...t screw 59 Hexagon nipple 7 Spring collar 60 Set screw 8 Inlet cone 61 Hexagon nipple 9 Sunk key 63 Bracket 10 Mech shaft seal 64 Set screw 11 Water deflector 67 Set screw 12 Ring lock 69 Guard 13 Bal...

Страница 133: ...RE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 131 E mail desmi desmi com www desmi com 11 17 Assembly drawing NSL200 250 300 525 12...

Страница 134: ...0 Set screw 4 Sealing ring 61 Hexagon nipple 5 Impeller 63 Bracket 6 Set screw 64 Set screw 7 Spring collar 67 Set screw 8 Inlet cone 69 Guard 9 Sunk key 73 Pointed screw 10 Mech shaft seal 81 Sealing...

Страница 135: ...SPARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 133 E mail desmi desmi com www desmi com 11 19 Assembly drawing NSL350 525 02 comb...

Страница 136: ...6 Nut 47 Washer 7 Spring washer 58 Pipe 8 Inlet cone 59 Hexagon nipple 9 Sunk key 61 Hexagon nipple 10 Mech shaft seal 64 Set screw 11 Water deflector 71 Set screw 12 Ring lock 73 Pointed screw 13 Bal...

Страница 137: ...SPARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 135 E mail desmi desmi com www desmi com 11 21 Assembly drawing NSL350 525 12 comb...

Страница 138: ...3 Pipe plug 47 Washer 4 Sealing ring 58 Pipe 5 Impeller 59 Hexagon nipple 6 Nut 61 Hexagon nipple 7 Spring washer 64 Set screw 8 Inlet cone 71 Set screw 9 Sunk key 73 Pointed screw 10 Mech shaft seal...

Страница 139: ...umping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 137 E mail desmi desmi com www desmi com 11 23 Assembly drawing NSL 215 265 14 combination See 330 415...

Страница 140: ...g washer 74 Elastomer 8 Washer 76 Allen screw 9 Sunk key 77 Allen screw 10 Mech shaft seal 79 Nut 11 Water deflector 81 Sealing washer 12 Ring lock 84 Lubricator nipple 13 Ball bearing 86 Pointed scre...

Страница 141: ...PARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 139 E mail desmi desmi com www desmi com 11 25 Assembly drawing NSL 330 415 465 14 c...

Страница 142: ...Coupling bush 10 Mech shaft seal 76 Allen screw 11 Water deflector 81 Sealing washer 12 Ring lock 84 Lubricator nipple 13 Ball bearing 86 Pointed screw 14 Grease valve ring 93 Set screw 15 Ball beari...

Страница 143: ...SPARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 141 E mail desmi desmi com www desmi com 11 27 Assembly drawing NSL300 418 14 comb...

Страница 144: ...Pointed screw 10 Mech shaft seal 74 Coupling bush 11 Water deflector 76 Allen screw 12 Ring lock 81 Sealing washer 13 Ball bearing 84 Lubricator nipple 14 Grease valve ring 86 Pointed screw 15 Ball be...

Страница 145: ...RE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 143 E mail desmi desmi com www desmi com 11 29 Assembly drawing NSL200 250 300 525 14...

Страница 146: ...73 Pointed screw 11 Water deflector 74 Coupling bush 12 Ring lock 76 Allen screw 13 Ball bearing 81 Sealing washer 14 Grease valve ring 84 Lubricator nipple 15 Ball bearing 86 Pointed screw 16 Sunk k...

Страница 147: ...SPARE PARTS DESMI Pumping Technology A S Tagholm 1 9400 N rresundby Denmark Tlf nr 45 96 32 81 11 Fax 45 98 17 54 99 145 E mail desmi desmi com www desmi com 11 31 Assembly drawing NSL350 525 14 comb...

Страница 148: ...haft seal 72 Spacer 11 Water deflector 73 Pointed screw 12 Ring lock 74 Coupling bush 13 Ball bearing 76 Allen screw 14 Grease valve ring 81 Sealing washer 15 Ball bearing 84 Lubricator nipple 16 Sunk...

Страница 149: ...If the motor shaft is too long then it has to be machined milled to nominal length It has to be checked if the shaft sealing have the correct length when mounted on the pump shaft as shown below I e...

Страница 150: ...n during the mounting procedure Also any fingerprints shall be removed with alcohol or another suitable solvent NOTE ELK shaft seals must be turned after installation So O rings springs and sliding su...

Страница 151: ...1 11 Fax 45 98 17 54 99 149 E mail desmi desmi com www desmi com APPENDIX B Assembly drawing of Lip seal kit in cover under bearing The lip seal kit is optional Figure 13 1 Lip seal kit in cover under...

Отзывы: