The total diameter (including the plastic coat) of the wire/cable has to be
NO MORE
than 1/8” (3.175mm) in order for the
wire/cable to pass freely through the release mechanism assembly, once the release lever arm is opened.
Two ends of the cable should be crimped together into a loop.
The crimp bracket holding the ends
of the loop together must be made out of stainless steel in order to prevent a dissimilar metal
corrosion and a subsequent disconnect of the loop's ends.
During the loop's manufacturing,
please ensure proper crimp placement over the cable ends. Pay close attention to the amount of
force used to secure the crimp. Please make sure to use a proper crimping tools so that the loops
ends are secured and the loop wire is capable of withholding the adequate amount of force.
2.1 Follow this sequence in order to install/replace the
nickel-chromium wire:
STEP 1:
Loosen the setscrews at the top of the two posts using a size 5/64” Allen wrench.
Содержание Acoustic Release Control System
Страница 3: ......
Страница 25: ......
Страница 33: ... Control Panel Device Manager Ports COM LPT ...
Страница 35: ......
Страница 44: ...STEP 6 Click Continue button The ARC unit will be added to the main window s list ...
Страница 62: ......