background image

111253-01A

For more information, visit www.desatech.com

For more information, visit www.desatech.com

22

Figure 38 - Installing Rear Brick Panel

Figure 39 - Installing Left Side and Top Brick Panels

Rear Brick Panel

Left Side
Brick Panel

10. Close glass door and lock latches on top and bottom of door

and replace screen. See Removing/Replacing Glass Door, steps
5 and 6, page 21.

11. Close top and bottom louvers.

INSTALLING LOGS, LAVA ROCK AND
GLOWING EMBERS

Each log is marked with a number. These numbers will help you
identify the log when installing. It is very important to install these
logs exactly as instructed. Do not modify logs. Only use logs
supplied with fireplace.

Open louvers, remove screen, unlock door latches, and open glass
door. See Removing/Replacing Glass Door, steps 1 and 2, page 21.
Install logs according to instructions for fireplace model numbers.

1.

Place log #1 (base log) onto pin on left front side of grate as
shown in Figure 40.

Figure 40 -  Installing Log No. 1

1

1

INSTALLING OPTIONAL BRICK LINER
MODELS BL36DA(SA) AND BL36DHA(SA)

 WARNING: If fireplace has been running, turn

off and unplug fireplace. Let cool before installing
brick liner.

This brick liner kit is optional. You may purchase brick liner from
your local retailer or see Accessories, page 37.

 CAUTION: Always handle brick panels with two

hands. Do not force brick panels into place. Exces-
sive force will break brick panels.

1.

Remove top and bottom louvers to allow access to door latches.

2.

Remove screen, unlock door latches and open glass door. See
Removing/Replacing Glass Door, steps 1 and 2, page 21.

3.

If installing brick liner in new fireplace, go to step 4. If install-
ing brick liner in an existing fireplace, carefully remove logs,
lava rock, and ember material.

4.

Remove three screws from deflector shield on the inside top
of firebox. Set shield and screws aside.

5.

Install rear brick panel first. Rest bottom edge of panel on back
edge of grate (see Figure 38).

6.

Install left side brick panel by sliding it between the grate and
the side of the firebox (see Figure 39).

7.

Install the right brick panel using the same method described
in step 6 for left brick panel.

8.

Replace deflector shield using screws removed in step 4.

9.

Install logs, lava rock and glowing embers. See Installing Logs,
Lava Rock and Glowing Embers, 
pages 22 and 23.

FIREPLACE INSTALLATION

Continued

FIREPLACE INSTALLATION

Installing Optional Brick Liner Models BL36DA(SA) and BL36DHA(SA)

Содержание VV36ENA1 Series

Страница 1: ...ent alteration service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation consult a quali...

Страница 2: ...center venting system Itbringsinfreshairforcombustionthroughtheouterpipeand combustion gases are exhausted through the inner pipe If the glass door assembly and venting pipe are not properly seated co...

Страница 3: ...se this fireplace to cook food or burn paper or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fireplace nameplate 14 Th...

Страница 4: ...the location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel burning fireplace or appliance Due to high temperatures do not...

Страница 5: ...combus tible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with your pri mary heating system Do n...

Страница 6: ...nlet 72 inches 182 9cm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum...

Страница 7: ...ing ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these instructions completely be fore a...

Страница 8: ...f adjacent pipes Push pipe sections together and twist one section clockwise approxi mately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be sup p...

Страница 9: ...off Position the standoff cap assembly in the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11 The siding standoff must sit flush against the exteri...

Страница 10: ...chart with critical minimum and maximum dimensions which MUST be met IMPORTANT Rememberthatahorizontalrunofventingmust have a 1 4 rise for every 12 of run toward the termination Figure 13 Typical Hori...

Страница 11: ...ntallythroughwall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations...

Страница 12: ...NG INSTALLATION INSTRUCTIONS Installation Planning Cont HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal sys...

Страница 13: ...a above is a room install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow con...

Страница 14: ...Round High Wind Termination Shown Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 40 max Figure23 VerticalVentingCon...

Страница 15: ...Horizontal Run Vertical Round High Wind Termination Shown Note Install restrictor into inner collar of fireplace as shown 45 Elbow PARTS LISTS FOR VENTING KITS AND COMPONENTS FOR V36 AND VV36 SERIES D...

Страница 16: ...ion Galvanized 1 01496 Horizontal Square Termination Galvanized 1 FIREPLACE INSTALLATION VENTING INSTALLATION INSTRUCTIONS Parts Lists for Venting Kits and Components FIREPLACE INSTALLATION Check Gas...

Страница 17: ...ide of the firebox Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox b If your firebox installation is recessed and or pre wired plug the power cord in...

Страница 18: ...til it clicks off If the blower is ON and has been running with the fireplace operating the blower will continue to run for a short time after the fireplace has been turned off As the thermal switch c...

Страница 19: ...n must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from fireplace see Figure 31 IMPORTANT Install main...

Страница 20: ...t provided 1 Open lower louver door panel by gently pulling forward 2 Route flexible gas line provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one...

Страница 21: ...louvers outward To install or replace items removed simply reverse the procedures above Figure 36 Removing Louver Panel Louver Panel CAUTION Wear gloves and safety glasses while handling or removing...

Страница 22: ...et cool before installing brick liner This brick liner kit is optional You may purchase brick liner from your local retailer or see Accessories page 37 CAUTION Always handle brick panels with two hand...

Страница 23: ...ont of firebox bottom in ar eas that are visible only It is not necessary to use all of the lava rock provided NOTICE Do not put lava rock on burner or under burner Placing lava rock on burner will ca...

Страница 24: ...lower louver panel Figure 47 Installing the WRC Remote Receiver Fireplace Receptacle Remote Control Receiver Extension Cord Ignition Module Plug Figure 48 Installing Battery into Back of Handset Pull...

Страница 25: ...lame appears at pilot If lighting the appliance for the first time each season it may take several attempts before the supply gas can reach the pilot and main burners If the appliance will not stay li...

Страница 26: ...ve any dust dirt or other obstructions that will hinder the flow of air BURNER FLAME PATTERN Burner flames will be steady not lifting or floating Flame patterns will be different from unit to unit and...

Страница 27: ...be used CLEANING AND MAINTENANCE CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING Donotopera...

Страница 28: ...d repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pi lot line 6 Replace control va...

Страница 29: ...ial OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burner is lit or shut off Slightsmokeorodorduringinitialoperation Gas odor even when control knob is in OFF position Gas odo...

Страница 30: ...30 ILLUSTRATED PARTS BREAKDOWN Models V V36ENA 1 V V36ENSA 1 V V36ENHA 1 V V36EPA 1 V V36EPSA 1 V V36EPHA 1 ILLUSTRATED PARTS BREAKDOWN MODELS V V36ENA 1 V V36ENSA 1 V V36ENHA 1 V V36EPA 1 V V36EPSA 1...

Страница 31: ...108011 02 Bottom Panel Louver Assy 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 109082 01 109082 01 Heat Shield 1 10 108032 01 108032 01 108032 01 Log Set 1 10...

Страница 32: ...TS BREAKDOWN Models V V36ENA 1 V V36ENSA 1 V V36ENHA 1 V V36EPA 1 V V36EPSA 1 V V36EPHA 1 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V V36ENA 1 V V36ENSA 1 V V36ENHA 1 V V36EPA 1 V V36EPSA...

Страница 33: ...1 4 PPH Zinc 4 16 26808 Valve Bracket 1 17 26827 Switch Bracket 1 18 11147 Screw 10 24 x 1 2 PPH Zinc 2 19 11186 Screw 8 32 x 1 Zinc 4 20 14115 Spade Tongue Connector 1 21 14120 Spade 1 4 Female Conn...

Страница 34: ...gas supplier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart mentat1 866 672 6040 Whencalling pleasehavey...

Страница 35: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Страница 36: ...111253 01A For more information visit www desatech com For more information visit www desatech com 36 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 37: ...FPD36P Filligree Panel Kit Platinum FPD36PB Filligree Panel Kit Polished Brass LOUVER TRIM KIT Rolled Louvers Only Not Shown LT36B Rolled Louver Trim Kit Brushed Brass LT36P Rolled Louver Trim Kit Pla...

Страница 38: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...

Отзывы: