111253-01A
For more information, visit www.desatech.com
For more information, visit www.desatech.com
9
9
WARNING: Do not recess vent termination into
any wall. This will cause a fire hazard.
6.
Noncombustible Exterior Wall:
Position the horizontal vent
cap in the center of the 8
1
/
2
" round hole and attach to the exte-
rior wall with four wood screws provided. Before attaching
the vent cap to exterior wall, run a bead of non-hardening mastic
(pliable sealant) around the outside edges to make a seal be-
tween it and the outside wall.
Note:
The four wood screws
provided should be replaced with appropriate fasteners for
stucco, brick, concrete, or other types of sidings.
Combustible Exterior Wall:
For vinyl siding, stucco, or wood
exteriors, a siding standoff must be installed between the vent
cap and exterior wall. The siding standoff prevents excessive
heat from damaging the siding materials. Siding material must
be cut to accommodate standoff. Bolt the vent cap to the stand-
off. Apply non-hardening mastic around outside edge of stand-
off. Position the standoff/cap assembly in the center of the 10
3
/
4
" square hole and attach to exterior wall with wood screws
provided (see Figure 11). The siding standoff must sit flush
against the exterior fascia material.
7.
Combustible Exterior Wall Only:
Slide the wall firestop over
the vent pipe before connecting horizontal run to vent cap (see
Figure 12).
8.
Carefully move fireplace, with vent assembly attached, toward
wall and insert vent pipe into horizontal termination. The pipe
overlap should be a minimum of 1
1
/
4
".
9.
Combustible Exterior Wall Only:
Slide wall firestop against
interior wall surface and attach with screws provided (see Figure
12). See Figure 13 for horizontal termination details.
VENTING INSTALLATION
INSTRUCTIONS
Continued
VENTING INSTALLATION INSTRUCTIONS
Installation Planning (Cont.)
Wood Screw
Vent Cap
Apply Mastic to
All Four Sides
Figure 10 - Installing Horizontal Vent Cap (Noncombustible
Exterior)
Cut Siding Away
to Fit Standoff
Wood Screw
Screws
Standoff
Vent Cap
Apply Mastic
to All Four Sides
Figure 11 - Installing Siding Standoff (Combustible Exterior)
Vent Cap
(Horizontal
Termination)
Interior Wall
Surface
Wall
Firestop
Horizontal
Vent Pipe
Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe
Screw