background image

111253-01A

For more information, visit www.desatech.com

For more information, visit www.desatech.com

23

23

FIREPLACE INSTALLATION

Continued

FIREPLACE INSTALLATION

Installing Logs, Lava Rock, and Glowing Embers

Figure 41- Installing Log No. 2

2

Figure 42 - Installing Log No. 3

3

2.

Rest left side of log #2 (front log) onto top of log #1. Place
right side of log onto second pin located on right side of grate
(see Figure 41).

3.

Place log #3 (rear log) onto pins on rear of grate as shown in
Figure 42.

4.

Place log #4 (crossover log) onto pins from both logs #2 and
#3 as shown in Figure 43.

5.

Place log #5 (top log) onto right pin of front log (#2) and the
smooth surface of crossover log (#4) as shown in Figure 44.
Make sure it is seated properly.

6.

Place log #6 (left log) onto left pin of front log (#2) and the
smooth surface of rear log (#3) as shown in Figure 45. Make
sure it is seated properly.

8.

Place lava rock along sides and front of firebox bottom in ar-
eas that are visible only. It is not necessary to use all of the
lava rock provided.

NOTICE: Do not put lava rock on burner or under
burner. Placing lava rock on burner will cause perfor-
mance problems.

9.

Pull ember material apart into pieces no larger than a dime.
Place these pieces loosely and sparingly directly onto the ex-
posed section of the front burner and along the space between
the burner and grate prongs (see Figure 46). This will create
the glowing ember appearance as the flame touches the ember
material. Do not block air slots by using too much ember ma-
terial in one area. It is not necessary to use all of the ember
material provided.

10. Close glass door, lock door latches, replace screen, and close

louvers (see Removing/Replacing Glass Door, steps 5 through
7, page 21).

 WARNING: The glass door must be securely in

place before running this fireplace. Do not run this
fireplace if glass is missing or broken.

Ember Material

Figure 46 - Placing Ember Material on Burner

Figure 44 - Installing Log No. 5

5

6

Figure 45 - Installing Log No. 6

Figure 43 - Installing Log No. 4

4

Содержание VV36ENA1 Series

Страница 1: ...ent alteration service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation consult a quali...

Страница 2: ...center venting system Itbringsinfreshairforcombustionthroughtheouterpipeand combustion gases are exhausted through the inner pipe If the glass door assembly and venting pipe are not properly seated co...

Страница 3: ...se this fireplace to cook food or burn paper or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fireplace nameplate 14 Th...

Страница 4: ...the location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel burning fireplace or appliance Due to high temperatures do not...

Страница 5: ...combus tible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with your pri mary heating system Do n...

Страница 6: ...nlet 72 inches 182 9cm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum...

Страница 7: ...ing ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these instructions completely be fore a...

Страница 8: ...f adjacent pipes Push pipe sections together and twist one section clockwise approxi mately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be sup p...

Страница 9: ...off Position the standoff cap assembly in the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11 The siding standoff must sit flush against the exteri...

Страница 10: ...chart with critical minimum and maximum dimensions which MUST be met IMPORTANT Rememberthatahorizontalrunofventingmust have a 1 4 rise for every 12 of run toward the termination Figure 13 Typical Hori...

Страница 11: ...ntallythroughwall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations...

Страница 12: ...NG INSTALLATION INSTRUCTIONS Installation Planning Cont HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal sys...

Страница 13: ...a above is a room install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow con...

Страница 14: ...Round High Wind Termination Shown Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 40 max Figure23 VerticalVentingCon...

Страница 15: ...Horizontal Run Vertical Round High Wind Termination Shown Note Install restrictor into inner collar of fireplace as shown 45 Elbow PARTS LISTS FOR VENTING KITS AND COMPONENTS FOR V36 AND VV36 SERIES D...

Страница 16: ...ion Galvanized 1 01496 Horizontal Square Termination Galvanized 1 FIREPLACE INSTALLATION VENTING INSTALLATION INSTRUCTIONS Parts Lists for Venting Kits and Components FIREPLACE INSTALLATION Check Gas...

Страница 17: ...ide of the firebox Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox b If your firebox installation is recessed and or pre wired plug the power cord in...

Страница 18: ...til it clicks off If the blower is ON and has been running with the fireplace operating the blower will continue to run for a short time after the fireplace has been turned off As the thermal switch c...

Страница 19: ...n must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from fireplace see Figure 31 IMPORTANT Install main...

Страница 20: ...t provided 1 Open lower louver door panel by gently pulling forward 2 Route flexible gas line provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one...

Страница 21: ...louvers outward To install or replace items removed simply reverse the procedures above Figure 36 Removing Louver Panel Louver Panel CAUTION Wear gloves and safety glasses while handling or removing...

Страница 22: ...et cool before installing brick liner This brick liner kit is optional You may purchase brick liner from your local retailer or see Accessories page 37 CAUTION Always handle brick panels with two hand...

Страница 23: ...ont of firebox bottom in ar eas that are visible only It is not necessary to use all of the lava rock provided NOTICE Do not put lava rock on burner or under burner Placing lava rock on burner will ca...

Страница 24: ...lower louver panel Figure 47 Installing the WRC Remote Receiver Fireplace Receptacle Remote Control Receiver Extension Cord Ignition Module Plug Figure 48 Installing Battery into Back of Handset Pull...

Страница 25: ...lame appears at pilot If lighting the appliance for the first time each season it may take several attempts before the supply gas can reach the pilot and main burners If the appliance will not stay li...

Страница 26: ...ve any dust dirt or other obstructions that will hinder the flow of air BURNER FLAME PATTERN Burner flames will be steady not lifting or floating Flame patterns will be different from unit to unit and...

Страница 27: ...be used CLEANING AND MAINTENANCE CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING Donotopera...

Страница 28: ...d repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pi lot line 6 Replace control va...

Страница 29: ...ial OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burner is lit or shut off Slightsmokeorodorduringinitialoperation Gas odor even when control knob is in OFF position Gas odo...

Страница 30: ...30 ILLUSTRATED PARTS BREAKDOWN Models V V36ENA 1 V V36ENSA 1 V V36ENHA 1 V V36EPA 1 V V36EPSA 1 V V36EPHA 1 ILLUSTRATED PARTS BREAKDOWN MODELS V V36ENA 1 V V36ENSA 1 V V36ENHA 1 V V36EPA 1 V V36EPSA 1...

Страница 31: ...108011 02 Bottom Panel Louver Assy 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 109082 01 109082 01 Heat Shield 1 10 108032 01 108032 01 108032 01 Log Set 1 10...

Страница 32: ...TS BREAKDOWN Models V V36ENA 1 V V36ENSA 1 V V36ENHA 1 V V36EPA 1 V V36EPSA 1 V V36EPHA 1 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V V36ENA 1 V V36ENSA 1 V V36ENHA 1 V V36EPA 1 V V36EPSA...

Страница 33: ...1 4 PPH Zinc 4 16 26808 Valve Bracket 1 17 26827 Switch Bracket 1 18 11147 Screw 10 24 x 1 2 PPH Zinc 2 19 11186 Screw 8 32 x 1 Zinc 4 20 14115 Spade Tongue Connector 1 21 14120 Spade 1 4 Female Conn...

Страница 34: ...gas supplier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart mentat1 866 672 6040 Whencalling pleasehavey...

Страница 35: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Страница 36: ...111253 01A For more information visit www desatech com For more information visit www desatech com 36 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 37: ...FPD36P Filligree Panel Kit Platinum FPD36PB Filligree Panel Kit Polished Brass LOUVER TRIM KIT Rolled Louvers Only Not Shown LT36B Rolled Louver Trim Kit Brushed Brass LT36P Rolled Louver Trim Kit Pla...

Страница 38: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...

Отзывы: