LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local
codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also
known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note:
Where listed vented decorative logs are required, thermostat operation is
not permitted.
Operation
This heater is clean burning. It requires no outside venting. There is no heat loss out
a vent or up a chimney. Heat is generated by both realistic flames and glowing coals.
This heater is designed for vent-free operation with flue damper closed. State and
local codes in some areas prohibit the use of vent-free heaters. You can operate heater
as a vented product by opening flue damper.
Safety Device
This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS).
The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot
shuts off the heater if there is not enough fresh air.
Piezo Ignition System
This heater has a piezo ignitor. This system requires no matches, batteries, or
other sources to light heater.
1. Remove logs and heater base assembly from carton.
Note:
Do not pick up
heater base assembly by burners. This could damage heater. Always handle
base assembly by grate.
2. Remove all protective packaging applied to logs and heater for shipment.
3. Check all items for any shipping damage. If damaged, promptly inform dealer
where you bought heater.
UNPACKING
PRODUCT
FEATURES
Continued
AIR FOR
COMBUSTION
AND
VENTILATION
WARNING ICON
G 001
WARNING
This heater shall not be installed in a confined space unless
provisions are provided for adequate combustion and ventila-
tion air. Read the following instructions to insure proper fresh
air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, in-
creased insulation, and new construction methods help reduce heat loss in homes.
Home owners weather strip and caulk around windows and doors to keep the cold
air out and the warm air in. During heating months, home owners want their
homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe.
Fresh air must enter your home. All fuel-burning appliances need fresh air for
proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air
from the house to operate. You must provide adequate fresh air for these appli-
ances. This will insure proper venting of vented fuel-burning appliances.