32
102652
OPTIONAL
POSITIONING
OF THERMOSTAT
SENSING BULB
For Masonry and
Factory-built
Metal Fireplace
If your log set cycles to pilot, but the room temperature drops to a lower than
ideal comfort level before the log set comes back on, you may want to
reposition the thermostat sensing bulb.
The thermostat sensing bulb is located on the gas valve assembly. This location allows the
thermostat to keep the room temperature at an ideal comfort level for most fireplace
applications. For positioning the thermostat sensing bulb elsewhere, an adhesive-backed
mounting clip has been provided.
Tools needed: 5/16" hex driver or socket
Thermostat
Sensing Bulb
Gas Valve
Assembly
Figure 34 - Location of Gas Valve Assembly and Thermostat Sensing Bulb
1. Locate the gas valve assembly and thermostat sensing bulb (see Figure 34).
2. The adhesive-backed mounting clip (see Figure 35) is attached to the thermostat sensing
bulb. Remove the adhesive-backed mounting clip.
Figure 35 - Adhesive-backed Mounting Clip
Figure 36 - Removing Thermostat Sensing Bulb
Capillary
Screw
Retaining Clamp
Thermostat Sensing Bulb
3. With 5/16" hex driver or socket, loosen the thermostat screw. Carefully slide the
thermostat sensing bulb out of the retaining clamp (see Figure 36).
Note:
Do not remove the screw. Make sure you tighten the screw after removing the
thermostat sensing bulb.
IMPORTANT:
Do not force or bend the thermostat sensing bulb or capillary.
4. The thermostat sensing bulb may be located to the lower right front side of fireplace.
Determine location of sensing bulb, but do not mount sensing bulb until step 5. If you