www.desatech.com
108661-01F
18
Open
FIREPLACE INSTALLATION
Continued
CHECKING GAS CONNECtIONS
WARNING: Test all gas piping and connections for
leaks after installing or servicing. Correct all leaks at
once.
WARNING: Never use an open flame to check for
a leak. Apply a noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct all leaks
at once.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect fireplace and its individual equipment shutoff valve
from gas supply piping system. Pressures in excess of 1/2 psig
(3.5 kPa) will damage fireplace gas regulator.
2. Cap off open end of gas pipe where equipment shutoff valve
was connected.
3. Pressurize supply piping system by either opening propane/LP
supply tank valve for propane/LP gas fireplace or opening main
gas valve located on or near gas meter for natural gas fireplace,
or using compressed air.
4. Check all joints of gas supply piping system. Apply noncor-
rosive leak detection fluid to all joints. Bubbles forming show
a leak. Correct all leaks at once.
5. Reconnect fireplace and equipment shutoff valve to gas supply.
Check reconnected fittings for leaks.
test Pressures Equal to or Less than 1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 33).
2. Pressurize supply piping system by either opening propane/LP
supply tank valve for propane/LP gas fireplace or opening main
gas valve located on or near gas meter for natural gas fireplace,
or using compressed air.
3. Check all joints from propane/LP supply tank or gas meter
to equipment shutoff valve (see Figure 34 for propane/LP or
Figure 35 for natural gas). Apply noncorrosive leak detection
fluid to all joints. Bubbles forming show a leak. Correct all
leaks at once.
Figure 33 - Equipment Shutoff Valve
Closed
Equipment
Shutoff
Valve
Figure 35 - Checking Gas Joints for Natural Gas Fireplace
Figure 34 - Checking Gas Joints for Propane/LP Gas
Fireplace
Propane/LP
Supply Tank
Gas Valve
Equipment
Shutoff
Valve
Gas
Meter
Gas Valve
Equipment
Shutoff
Valve
PRESSURE tEStING FIREPLACE GAS CONNECtIONS
1. Open equipment shutoff valve (see Figure 33).
2. Open propane/LP supply tank valve for propane/LP fireplace
or main gas valve located on or near gas meter for natural gas
fireplace.
3. Make sure control knob of fireplace is in the OFF position.
4. Check all joints from equipment shutoff valve to gas valve (see
Figure 34 or 35). Apply noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct all leaks at once.
5. Light fireplace (see
Operating Fireplace
, page 23). Check all
other internal joints for leaks.
6. Turn off fireplace (see
To Turn Off Gas to Appliance
, page 23).