background image

INSTALLATION

Continued 

INSTALLING HEATER BASE 
ASSEMBLY

 WARNING: You must secure 

this heater to fireplace floor. If 

not, heater will move when you 

adjust controls. Moving heater 

may  cause  a  gas  leak  or  log 

misplacement.

  WARNING:  If  installing  in  a 

sunken  fireplace,  special  care 

is  needed.  You  must  raise  the 

fireplace floor to allow access to 

heater control panel. This will in

-

sure adequate air flow and guard 

against sooting and controls be

-

ing damaged. Raise fireplace floor 

with  noncombustible  material. 

Make sure material is secure.

  CAUTION:  Do  not  pick  up 

heater base assembly by burners. 

This could damage heater. Only 

handle base assembly by grates.

IMPORTANT:

 Make sure the heater burners are 

level. If heater is not level, heater will not work 

properly. 

Installation Items Needed

•  hardware package (provided with heater)

•  approved flexible gas hose and fittings (not 

provided) (if allowed by local codes) 

• 

sealant (resistant to propane/LP gas, not 

provided)

•  electric drill with 3/16" drill bit (metal or ma

-

sonry as applicable)

•  flathead screwdriver

•  pipe wrench

1.  Apply pipe joint sealant lightly to male threads 

of gas fitting (not provided). Connect approved 

flexible gas hose to gas control fitting in heater 

(see Figure 11). 

IMPORTANT:

 Hold gas fitting 

with wrench when connecting flexible gas hose.

2.  Locate two masonry screws in hardware package. 

3.  Place heater base in fireplace.

4.  Place logs in their proper position on heater 

base (see 

Installing Logs

, page 16).

5.  Center heater base and logs front-to-back 

and side-to-side in fireplace.

6.  Carefully remove logs without moving heater 

base.

7.  Mark screw locations through one hole on 

each side of the base (see Figure 12). If install

-

ing in a brick-bottom fireplace, mark screw 

locations in mortar joint of bricks.

8.  Drill holes at marked locations using 3/16" 

drill bit. 

9.  Attach base assembly to fireplace floor using 

two masonry screws (in hardware package).

Figure 11 - Attaching Flexible Gas Hose 

to Heater

Flexible Gas Hose (if 
allowed by local codes)

Fitting

Figure 12 - Attaching Heater to Fireplace 

Floor

Masonry Screw

Screw Holes 
in Base

INSTALLING BATTERIES FOR 
REMOTE RECEIVER AND HAND 

HELD REMOTE CONTROL

Four AA batteries and three AAA batteries are 

required to operate this heater with the wireless 

hand-held remote control set. Four AA batteries 

must be installed in the receiver and three AAA 

batteries in the hand-held remote control unit. 

Note:

 Only use alkaline batteries.

Содержание LDL3924NR

Страница 1: ...e in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service mu...

Страница 2: ...s for installation only in a solid fuel burning mason ry or UL127 factory built fireplace orinalistedvent less firebox enclosure It is design certified for these installationsinaccordance with ANSI Z2...

Страница 3: ...anual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exchanger in...

Страница 4: ...air ventilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if enough fresh air is not available See Air for Combustion and Ven...

Страница 5: ...ystem This heater has a piezo ignitor This system re quires no matches batteries or other sources to light heater Air For Combustion and Ventilation WARNING This heater shall not be installed in a con...

Страница 6: ...municating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space Adjoining rooms are communicating only...

Страница 7: ...is fresh air would come from an adjoining un confined space When ventilating to an adjoining unconfined space you must provide two perma nent openings one within 12 of the ceiling and one within 12 of...

Страница 8: ...ted on floor or wall of fireplace If not drafting may cause pilot outage or sooting Useaheat resistantsealant Do not seal chimney flue damper WARNING Never install the heater in a bedroom or bathroom...

Страница 9: ...minimum clearances If you can provide greater clearances from floor ceiling and adjoin ing wall LOG SIZING REQUIREMENTS Log Size Minimum Firebox Height Depth Front Width Rear Width 24 17 14 28 21 30 1...

Страница 10: ...must operate heater with chimney flue damper open Go to Installing Damper Clamp Accessory for Vented Operation page 11 Mantel Clearances In addition to meeting noncombustible material clearances you m...

Страница 11: ...PERATION Note When used as a vented heater appliance must be installed only in a solid fuel burning fireplace with a working flue and constructed of noncombustible material You may use this heater as...

Страница 12: ...ing not provided Connect approved flexible gas hose to gas control fitting in heater see Figure 11 IMPORTANT Hold gas fitting with wrench when connecting flexible gas hose 2 Locate two masonry screws...

Страница 13: ...equipment shutoff valve from your dealer See Accessories page 31 For propane LP units the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must...

Страница 14: ...hook up NPT tap must be upstream from heater see Figure 16 IMPORTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to...

Страница 15: ...ocated on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 C...

Страница 16: ...approved withthisheatermayresultinprop erty damage or personal injury CAUTION After installa tion and periodically thereafter check to ensure that no flame comes in contact with any log With the heat...

Страница 17: ...ighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settl...

Страница 18: ...ill come on automatically within one minute when the control valve is in the ON position after the pilot is lit 1 STOP Read the safety information on page 17 2 Make sure equipment shutoff valve is ful...

Страница 19: ...nits will have a slight curve but flame should be blue and have no yellow or orange color Figure 27 Pilot Propane LP Ignitor Electrode Pilot Burner Figure 28 Pilot Natural Ignitor Electrode Pilot Burn...

Страница 20: ...lly switch off Child Safety Lock Out To lock the remote control keys press the On Off key then immediately press the up key see Figure 29 The lock out function is active when the lock icon is lit Repe...

Страница 21: ...ry from pilots shown Cleaning and Maintenance WARNING Turn off heater and let cool before cleaning CAUTION You must keep control areas burners and circulating air passageways of heater clean Inspect t...

Страница 22: ...inlet hole You may blow through a drinking straw if compressed air is not available Burner Tube Pilot Assembly Pilot Air Inlet Hole Ports Slots Burner Tube Injector Holder May Be Brass or Aluminum De...

Страница 23: ...pleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor ca...

Страница 24: ...d in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natural or propane LP gas company B Clean ODS pi...

Страница 25: ...es 9 through 11 4 Clean burners see Cleaning and Maintenance page 21 or replace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products 1 Refer to Air for...

Страница 26: ...3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between con trol valve and burner 2 Gas leak See Warning statement at top o...

Страница 27: ...ment Parts Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If they c...

Страница 28: ...Parts Breakdown models LDL3924NR LDL3924PR LDL3930NR and LDL3930PR F F P O 11 28 2 3 25 18 5 19 10 7 7 6 4 20 24 16 14 26 9 23 23 15 16 8 23 23 23 17 21 1 12 13 22 27 1 27 2 27 3 27 4 27 5 27 6 27 7 2...

Страница 29: ...rner Retainer Spring 1 20 103784 01 103784 01 103784 01 103784 01 Pilot Knob Extension 1 21 111442 02 111442 02 111442 02 111442 02 Digital Display Remote Control 1 22 111441 02 111441 02 111441 02 11...

Страница 30: ...39 000 Type Gas Propane LP Natural Ignition Piezo Piezo Manifold Pressure 8 0 W C 3 5 W C Inlet Gas Pressure in of water Maximum 14 10 5 Minimum 11 5 For purpose of input adjustment Specifications Wi...

Страница 31: ...ps deflect heat away from mantel or wall above fireplace Fits openings 28 to 48 wide DAMPER CLAMP GA6080 Not Shown For all models Permanently opens chimney flue damper for vented operation LAVA ROCK G...