background image

GENERAL HAZARD WARNING:

READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN

THIS MANUAL BEFORE ASSEMBLING, STARTING, OR 

SERVICING 

THE HEATER. 

Be sure to comply with the instructions and warnings provided with this 

heater. Failure to comply can result in fire or explosion that can cause property loss, bodily 

injury, or loss of life. Only persons who can follow and understand these instructions should 

operate or service this heater. If you need heater info; such as an operating manual, labels, 

etcetera, contact Pinnacle Climate Technologies at 800-641-6996.

NOT FOR USE IN RESIDENTIAL LIVING
ADEQUATE VENTILATION. FOR OUTDOOR

 

USE. INDOOR USE PERMITTED ONLY FOR:

 

THE TEMPORARY 

HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES 

UNDER CONSTRUCTION, ALTERATION OR REPAIR. 

This is an unvented 

portable heater that uses air (Oxygen) from within the area in which it is 

used.  Failure to provide adequate combustion and ventilation air will 

result in asphyxiation, carbon monoxide poisoning, bodily injury or death. 

Refer to “Ventilation” on Page 7.

MODEL NUMBERS:

PT-80-OFR / PT-125-OFR-A

CONSUMER: READ AND SAVE THESE 

INSTRUCTIONS

Factory ID: 001

DANGER

DANGER 

AREAS OR IN ENCLOSED SPACES WITHOUT

KEROSENE RADIANT HEATER

 

User’s Manual & 

Operating Instructions

Sauk Rapids, MN 56379 USA • Toll Free 

(800) 641-6996

Fax: 320-251-2922 • Web: 

www.protemp.us

 • Email: [email protected]

© 2019 Pinnacle Climate Technologies, Inc.

PTRG-405

U.S. Patent No. 9,644,863

Locating Your Serial Number:

Your serial number can be found on a blue label on the left side cover. It will begin with the letter “S” 

followed by 9 digits. For Example: S160901126. Have your Serial Number ready before calling cus-

tomer service at 800-641-6996.

®

Summary of Contents for PT-125-OFR-A

Page 1: ...ALTERATION OR REPAIR This is an unvented portable heater that uses air Oxygen from within the area in which it is used Failure to provide adequate combustion and ventilation air will result in asphyx...

Page 2: ...ART THE HEATER WHEN THE CHAMBER IS HOT WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as recommended by these instructions Never use the heater in spaces which contai...

Page 3: ...he products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heating of buildings under construction alter...

Page 4: ...ption Gal Hr L Hr 0 63 2 38 0 85 3 22 Fuel Tank Capacity Gal L 4 15 14 14 53 00 Max Operating Hours 6 20 Volts AC Hz 120V 60Hz 120V 60Hz Amps 3 15 3 15 Heating Area ft2 2000 3125 Specifications subjec...

Page 5: ...2 Attach the handle while still in the box for easier unpacking see Figures 1 and 2 Carry Handle 1 Black Screws 2 80 OFR 1 Remove existing screws from shell ring on either side of heater see Figure 3...

Page 6: ...ed see Figure 8 5 Attach top safety guard using the two outer most extra screws on the top of the radiant cone see Figure 9 Note Save the box and packaging materials for future storage Figure 6 Figure...

Page 7: ...sunlight or near a source of heat NEVER use Kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD Kerosene WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene...

Page 8: ...er fails to ignite check this fuse first and replace if necessary Also check the power source to be sure the proper voltage is being provided to the heater 1 Complete steps 1 3 above 2 Push the power...

Page 9: ...y SPARK PLUG Clean and re gap every 600 hours of operation or replace as needed After removing the Spark Plug clean the terminals with a wire brush Re gap the terminals to 0 140 3 5 mm see Figure 12 F...

Page 10: ...nozzle in clean Kerosene or diesel to help loosen any particles see Figure 14a and 14b PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions Use a...

Page 11: ...limate Technologies Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 125 OFR A WIRING DIAGRAMS AC 120V 60Hz AC 250V 3 15A ELEC...

Page 12: ...lug 3 Clean replace Fuel Filter 4 Clean replace Nozzle 5 Rinse out fuel tank with clean fresh Kerosene diesel 6 Inspect all electrical connections See Wiring Diagrams Page 11 7 Re attach Transformer w...

Page 13: ...gies Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE EXPLODED VIEW 25 23 24 9 21 22 20 19 26 10 7 28 6 4 3 1 2 27 8 12 13 29...

Page 14: ...0650 9 Ignitor 75 025 0120 10 Main PCB Assembly 75 025 0400 11 Tip Over Sensor 75 051 0200 12 Cooling Motor Assembly 75 047 0250 13 Cooling Fan 75 047 0200 14 Handle 75 001 0060 15 Temperature Limit S...

Page 15: ...c Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22 21 30 23 26 19 34 27 29 4...

Page 16: ...mp 72 027 0100 11 Main PCB and Fuse 72 025 0450 12 Tip Over Sensor 75 051 0200 13 Power Cord 72 032 0150 14 Power Switch 72 012 0120 15 Back Cover 72 013 0110 16 Panel sub PCB 72 014 0100 17 Blower Mo...

Page 17: ...f Pinnacle Climate Technnologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express...

Page 18: ...Sauk Rapids MN 56379 USA Toll Free 800 641 6996 Fax 320 251 2922 Web www protemp us Email info pinnacleclimate com 2019 Pinnacle Climate Technologies Inc...

Reviews: