3

 DANGER: Carbon monoxide 

poisoning may lead to death!

Carbon Monoxide Poisoning:

.Early.signs.of.

carbon monoxide poisoning resemble the flu, 
with headaches, dizziness or nausea. If you 
have  these  signs,  the  fireplace  may  not  be 

working.properly..Get.fresh.air.at.once!.Have.

fireplace serviced. Some people are more af

-

fected.by.carbon.monoxide.than.others..These.

include pregnant women, people with heart or 
lung disease or anemia, those under the influ

-

ence.of.alcohol.and.those.at.high.altitudes.

Natural and Propane/LP Gas:

.Natural.and.

propane/LP. gases. are. odorless..An. odor-
making.agent.is.added.to.the.gas..The.odor.

helps  you  detect  a  gas  leak.  However,  the 

odor.added.to.the.gas.can.fade..Gas.may.be.
present.even.though.no.odor.exists.
Make. certain. you. read. and. understand. all.
warnings..Keep.this.manual.for.reference..It.
is.your.guide.to.safe.and.proper.operation.of.

this fireplace.

  WARNING:  Any  change  to 

this fireplace or its controls can 

be dangerous.

 WARNING: Do not use a blow

-

er insert, heat exchanger insert or 

other accessory not approved for 

use with this fireplace.

 WARNING: Do not allow fans 

to blow directly into the fireplace. 

Avoid any drafts that alter burner 

flame patterns. Ceiling fans can 

create  drafts  that  alter  burner 

flame  patterns.  Altered  burner 

patterns can cause sooting.

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

SAFETy

Continued

Do not place clothing or other 

flammable  material  on  or  near 

the appliance. Never place any 

objects on the heater.

Fireplace  front  and  screen  be

-

come  very  hot  when  running 

heater. Keep children and adults 

away from hot surfaces to avoid 

burns or clothing ignition. Fire

-

place will remain hot for a time 

after shutdown. Allow surfaces 

to cool before touching.

Carefully supervise young chil

-

dren when they are in the room 

with fireplace.

You must operate this fireplace 

with the fireplace screen in place. 

Make sure fireplace screen is in

-

stalled before running fireplace.

Keep  the  appliance  area  clear 

and free from combustible ma

-

terials, gasoline and other flam

-

mable vapors and liquids.

1.. This.appliance.is.only.for.use.with.the.type.

of.gas.indicated.on.the.rating.plate..This.
appliance.is.not.convertible.for.use.with.
other.gases.

2.. Do.not.place.propane/LP.supply.tank(s).

inside.any.structure..Locate.propane/LP.
supply.tank(s).outdoors.

3.. If.you.smell.gas

•.shut.off.gas.supply
•.do.not.try.to.light.any.appliance
•.do.not.touch.any.electrical.switch;.do.not.

use.any.phone.in.your.building

•.immediately.call.your.gas.supplier.from.

a. neighbor’s. phone.. Follow. the. gas.
supplier’s.instructions

• if  you  cannot  reach  your  gas  supplier, 

call the fire department

4.  This fireplace shall not be installed in a 

bathroom.

Содержание HGC23TON

Страница 1: ...y appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your...

Страница 2: ...om in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 7 of this manual This appliance may be...

Страница 3: ...ered burner patterns can cause sooting Due to high temperatures the appliance should be located out oftrafficandawayfromfurniture and draperies SAFETY Continued Do not place clothing or other flammabl...

Страница 4: ...a of fireplace 7 This fireplace is designed to be smokeless If logs ever appear to smoke turn off fire place and call a qualified service person Note During initial operation slight smok ing could occ...

Страница 5: ...el from carton Log is wrapped and inside fireplace Do not remove at this time 2 Remove all protective packaging applied to fireplace for shipment 3 Make sure fireplace includes one hard ware packet 4...

Страница 6: ...16 hex wrench slotted screwdriver scissors 1 Remove two screws that hold fireplace screen in place for shipping These screws are located near top of screen Discard screws Lift fireplace screen up and...

Страница 7: ...that leaks around doors and windows may provide enough fresh air for combus tion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually ti...

Страница 8: ...Figure 4 on page 9 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts 30 000 10 000 40 000 DETERMINING FRESH AIR...

Страница 9: ...or required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the attic will...

Страница 10: ...easy access for operation inspection and service in coldest part of room CAUTION This fireplace cre ates warm air currents These currents move heat to wall sur faces next to fireplace Installing fire...

Страница 11: ...or Combustible to Wall Minimum 16 from Side Wall Example NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Walls and mantels above the firebox may become hot to the touch...

Страница 12: ...gas line to fireplace gas regulator See Connecting to Gas Supply page 14 5 Check all gas connections for leaks See Checking Gas Connections page 14 CONNECTING TO GAS SUPPLY WARNING Thisappliancere qu...

Страница 13: ...e Flexible Gas Line from Fireplace Gas Regulator Provided With Fireplace To Gas Regulator Equipment Shutoff Valve Propane LP To External Regulator NaturAL To Gas Supply CONNECTING Fireplace to Gas Sup...

Страница 14: ...supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive le...

Страница 15: ...see Figure 12 page 14 or Figure 13 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light fireplace see Operation page 16 Check all othe...

Страница 16: ...he screen in place Make sure fireplace screen is installed before run ning fireplace Figure 15 Control Knob In The OFF Position Piezo Ignitor Control Knob NOTICE During initial opera tion of new firep...

Страница 17: ...ROCEDURE 1 Follow steps 1 through 5 under Lighting Instructions page 16 2 With control knob pressed in strike match Hold match to pilot until pilot lights 3 Keep control knob pressed in for 30 sec ond...

Страница 18: ...2 Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 22 3 Blow air through the ports slots and holes in the burner 4 Check the injector holder located at...

Страница 19: ...replace and let cool before servicing Only a qualified service person should service and repair fireplace CAUTION Never use a wire needle or similar object to clean ODS pilot This can damage ODS pilot...

Страница 20: ...w gas pressure B Dirty or partially clogged ODS pilot 5 Thermocouple connection loose at control valve 6 Thermocouple damaged 7 Control valve damaged 1 Inlet gas pressure is too low 2 Burner orifice i...

Страница 21: ...heated vapors from furniture polish wax carpet cleaners etc may turn into white powder residue 1 Not enough combustion ventilation air REMEDY 1 Contact local natural or propane LP gas company 2 Clean...

Страница 22: ...2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning...

Страница 23: ...Service Department at 1 866 672 6040 When calling please have your model and serial numbers of your heater ready You can also visit DESA Heating Prod ucts technical services web site at www desatech...

Страница 24: ...om 121623 01A 24 1 2 34 41 42 41 3 39 4 32 15 16 20 41 41 41 29 26 27 30 14 28 34 23 33 38 21 22 31 43 17 25 36 40 35 40 15 16 24 34 19 18 5 6 7 8 9 34 11 13 10 37 12 Parts Firebox for Models HGC23TON...

Страница 25: ...098271 12 Ignitor Cable 1 27 107486 01 ODS Pilot Propane LP Gas 1 107485 01 ODS Pilot Natural Gas 1 28 119425 03 Injector NG 1 119425 02 Injector LP 1 29 099387 08 Pilot Tube 1 30 112881 03 Pilot Shie...

Страница 26: ...6 Parts Mantel for Models HGC23TON AND HGC23TOP 1 2 3 4 5 KEY NO PART NO DESCRIPTION QTY 1 121628 02 Mantel Top 1 2 121628 03 Mantel Left Leg 1 3 121628 04 Mantel Right Leg 1 4 121628 05 Mantel Header...

Страница 27: ...revent performance problems This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance Fire Crackle CF6 A1 For all models Creates the sound of a real b...

Страница 28: ...2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com 121623 01 Rev A 05 07 NOT A UPC 121623 01...