background image

 

75 

Scanning Code 39 

 

Disable 

 

 

Enable without a check digit (default) 

 

Enable with a check digit   
(Check digit transmission enabled) 

 

 

Enable with a check digit   

(Check digit transmission disabled) 

 

Transmission of Start/Stop codes for Code 39 

 

Disable (default) 

 

 

Enable 

 

Scanning Code 93 

 

Disable (default) 

 

 

Enable 

 

Scanning GS1 DataBar (RSS) 

 

Disable (default) 

 

 

Enable 

 

Scanning Composite 

 

Disable (default) 

 

 

Enable 

 

Содержание SE1-QB

Страница 1: ...2D Code Handy Scanner SE1 QB User s Manual...

Страница 2: ...ns without permission in writing from the publisher QR code SQRC and QBdirect are trademarks of DENSO WAVE INCORPORATED iPad and iPhone are trademarks of Apple Inc Microsoft Windows is a trademark of...

Страница 3: ...Wireless Link is Broken 13 Chapter 4 Configuring Scanner Parameters 14 Chapter 5 Scanning Control 15 5 1 Trigger Switch Control 15 Chapter 6 Magic Key Control 16 Chapter 7 Scanning Functions 17 7 1 Ed...

Страница 4: ...ata Packaging Packetizing 46 Chapter 10 Parameters and Defaults 49 Chapter 11 QR coded Parameter Menu 66 11 1 Customizing the Scanner with the QR coded Parameter Menu 66 11 2 QR coded Parameter Menu 6...

Страница 5: ...rocessing system s or equipment or software not supplied from DENSO WAVE ii the use of DENSO WAVE s products in a manner for which the same were not intended nor designed or iii any modification of DE...

Страница 6: ...se conditions that could cause serious bodily injury or death if the instructions are not followed correctly Alerts you to those conditions that could cause minor bodily injury or substantial property...

Страница 7: ...ever put the battery into a microwave oven or high pressure container Doing so could cause the batteries to break generate heat rupture or burn Avoid dropping the battery or letting it undergo any sho...

Страница 8: ...ing remove the battery and contact your nearest dealer Failure to do so could cause fire or electrical shock Do not use the scanner where any inflammable gases may be emitted Doing so could cause fire...

Страница 9: ...ure changes Moisture will get into the scanner resulting in malfunction fire or electrical shock Do not place the scanner anyplace where it may be subjected to oily smoke or steam e g near a cooking r...

Страница 10: ...cracked housing electrical shock or fire Do not use the scanner with anti slip gloves containing plasticizer The scanner housing may be broken creating injuries electrical shock or fire When taking c...

Страница 11: ...er SE1 QB 2 Communications adapter BA series Components required for individual interfaces For RS 232C interface 3 RS 232C interface cable CBBA RS2000 9 For USB keyboard or USB COM interface 4 USB int...

Страница 12: ...times block wireless networking The following environments can sometimes block wireless networking Metal objects or particles in the vicinity Metal walls around the area Excessive vibration The commun...

Страница 13: ...ate with a cotton swab or the similar soft one gently If sand or hard particles have accumulated never rub the plate doing so will scratch or damage it Blow the particles away with an airbrush or a so...

Страница 14: ...o replace the batteries Trigger switch Press this switch to start scanning Also establishes a Bluetooth wireless link when the Bluetooth wireless link is broken with the scanner turned on The reading...

Страница 15: ...cover lock 1 and remove the battery cover 2 2 Make sure that the new batteries are in the correct orientation when inserting them Insert the new batteries in the direction indicated by the arrow The...

Страница 16: ...e to thoroughly read the User s Manual for the batteries and follow written instructions to ensure correct use A rechargeable nickel metal hydride battery eneloop battery capacity 1900 mAh or equivale...

Страница 17: ...en the scanner is turned off pressing the magic key will start the Bluetooth wireless link Using the scanner when the End operation is selected requires scanning the Start operation QR Code symbols gi...

Страница 18: ...view except when multi line code scanning is allowed Having more than one code within the field of view either causes the scan to fail or produces multiple input The scanner can scan codes omnidirecti...

Страница 19: ...where the Bluetooth radio waves 2400 to 2483 5 MHz maximum 2 5 mW present a potential safety risk This scanner interprets the End operation QR Code symbol given in Section 11 2 according to the proced...

Страница 20: ...roneous input data When connecting the scanner to an iPhone iPad Android PC or other device The scanner can be connected to an iPhone iPad Android PC or other device equipped with a Bluetooth module t...

Страница 21: ...roid Setup icon 2 Select Bluetooth 3 Select SE1 4 When the PIN code confirmation is displayed enter 1234 5 When the scanner is successfully connected SE1 is displayed on the paired device Connect is d...

Страница 22: ...a while the scanner sounds the beep twice 4 The next time connecting to the device simply press the trigger switch Only when connecting with the same device When using the configuration software Scan...

Страница 23: ...ss to the scanner When using a commercially available code generator generate it in the following format Code type Data format QR Code Model 1 2 ADDRXXXXXXXXXXXX Code 128 Code Set A ADDRXXXXXXXXXXXX N...

Страница 24: ...e User s Manual for the respective device 5 Wait for the BA series communications adapter or commercially available Bluetooth equipment to establish a Bluetooth wireless link with the scanner as a sla...

Страница 25: ...he Cancel Scan w Bluetooth link broken QR Code symbol to set cancel and then press the trigger switch When the scanner was turned off by an auto power off press the magic key When the Bluetooth commun...

Страница 26: ...w Bluetooth link broken Allows the scanner to scan codes with the Bluetooth wireless link broken It also disables the Bluetooth interface making data transfer with the host computer impossible Cancel...

Страница 27: ...nload from our website at http www qbdirect net Note Customizing the scanner with the configuration software or batch process QR Code symbols breaks the Bluetooth wireless link so it is necessary to e...

Страница 28: ...ssfully completed or after approximately five seconds elapsed with the trigger switch pressed The scanner goes to the Ready state if the trigger switch is released before five seconds elapse 2 Momenta...

Страница 29: ...wireless link To end the Bluetooth wireless link hold down the magic key for at least five seconds Breaking of the Bluetooth wireless link by using the magic key can be disabled in the configuration s...

Страница 30: ...specified delimiters selectable from headers terminators commas and tabs instead of AIs to output them Extraction conditions Extraction conditions Choices Data transfer regardless of error result Perm...

Страница 31: ...ut data 01 11 17 STX 94901234567894 030808 040208 ETX 17 11 STX 040208 030808 ETX 17 17 STX 040208 040305 ETX 12 Error 01 12 Error 01 01 Error Data transfer regardless of error result Prohibit 01 11 1...

Страница 32: ...itions Data read Output data 0194901234567894110308081303 081017040208 STX 01 94901234567894 11 030808 13 030 810 17 040208 ETX Data transfer regardless of error result Prohibit 0194901234567894110308...

Страница 33: ...e YYMMDD 20 n2 n2 Product Variant 21 n2 an 20 Serial Number 22 n2 an 29 HIBCC Health Industry Business Communication Council Quantity Date Batch and Link 23n n3 n 19 Batch or Lot Number Transitional U...

Страница 34: ...Meters Logistics 334n n4 n6 Area Square Meters Symbology 335n n4 n6 Gross Volume Liters 336n n4 n6 Gross Volume Cubic Meters 337n n4 n6 Kilograms per Square Meter pressure 340n n4 n6 Gross Weight Pou...

Страница 35: ...nd ISO Currency Code 392n n4 n15 Amount Payable for a Variable Measure Trade Item Single Monetary Area 393n n4 n3 n15 Amount Payable for a Variable Measure Trade Item and ISO Currency Code 400 n3 an 3...

Страница 36: ...rocessing Places 8001 n4 n14 Roll Products Width Length Core Diameter Direction and Splices 8002 n4 an 20 Cellular Mobile Telephone Identifier 8003 n4 n14 an 16 EAN UCC Global Returnable Asset Identif...

Страница 37: ...h DD must be filled with 00 n indicates the length of data n indicates the decimal point position a a3 a 3 Alphabetic characters 3 alphabetic characters fixed length Up to 3 alphabetic characters n n3...

Страница 38: ...ncluding residue calculation e g transformation of units 7 Substituting data 8 Comparing character strings 9 Driving indicator LED and beeper The ADF script mode can be programmed with the configurati...

Страница 39: ...enabled the time required for scanning may increase 7 4 Scanning a Black and white Inverted Code The scanner usually scans a black and white normal code black cells bars on a white background You can...

Страница 40: ...a single split Code symbol is read the scanner sends the data read to the host computer When scanning Structured Appended Code symbols the scanner beeps in a different way from usual That is when the...

Страница 41: ...r of digits will be omitted 2 Comma delimited output format Specifying this format allows the scanner to output multiple lines of barcode data delimited with commas in the data transmission format sel...

Страница 42: ...occurred when the scanner was communicating with the configuration software Scan Tune App the encryption key of read data does not match the one configured in the scanner in SQRC scanning when the da...

Страница 43: ...tion software Scan Tune App Note Enabling the Bluetooth interface with the Start operation QR Code symbol allows the beeper volume to be adjusted Each time the Beeper volume QR Code symbol is scanned...

Страница 44: ...ger switch is pressed when a Bluetooth wireless link is broken the trigger switch is pressed on End operation or the remaining battery level is found to be less than 10 as a result of performing the b...

Страница 45: ...canner receives an LED ON command LB LG or LR from the host computer refer to Appendix 2 when the configuration software Scan Tune App starts up or any setting is newly reflected when the scanner scan...

Страница 46: ...tch is in Momentary switching mode or Alternate switching mode In the Momentary switching mode holding down the trigger switch turns on the marker beam continuously for approx 30 seconds When the scan...

Страница 47: ...upports the Serial Port Profile SPP that enables connecting to an Android PC or other device equipped with a Bluetooth module that is compatible with Bluetooth Specification Ver 2 1 EDR When the scann...

Страница 48: ...format bytewise Selecting this parameter does not output 80h to FFh data Scanning operation is completed when data is 80h to FFh Binary conversion Converts 00h to FFh data to binary format bytewise a...

Страница 49: ...inator The following describes each field in detail 1 Header Terminator The following choices are available SPP profile Header None default STX or User Selection Terminator CR default None LF CR LF ET...

Страница 50: ...Code type Type 1 Type 2 Type 3 Type 4 QR Code Q P01 Qm Edit mode Q P01 Qm Batch edit mode Q P01 Qm Structured Appended QR Code Non edit mode S P01 S MicroQR Code Q P01 Q SQRC Q iQR Code G Qm Edit mode...

Страница 51: ...F A E3 Without add on B FF A E4 With 2 digit add on B FF A E5 EAN 8 With 5 digit add on B FF A E6 Interleaved 2 of 5 I F Im Standard 2 of 5 short H G R0 Standard 2 of 5 normal H G S0 Code 39 M B Am C...

Страница 52: ...ithout add on V T E0 With 2 digit add on V T E3 EAN 13 CC A EAN 13 CC B EAN 13 With 5 digit add on V T E3 Without add on V T X0 With 2 digit add on V T X3 UPC E CC A UPC E CC B UPC E With 5 digit add...

Страница 53: ...from start code 0 No options 1 FNC1 preceding the 1st message character 2D codes Aztec 2 FNC1 subsequent to the 1st character or digit pair 0 Scanning enabled without a check digit 1 Scanning enabled...

Страница 54: ...only The scanner edits read code data and then transmits it It does not transmit the code number number of splits or parity In non edit mode The scanner transmits the code number the number of splits...

Страница 55: ...13 X14 X15 0 Padding character for adjustment of the data length S Number system character X11 15 Add on code data UPC E You can select whether or not to transmit the padding character 0 number system...

Страница 56: ...S X1 X2 X3 X4 X5 0 0 0 0 X6 C D X7 X8 X9 X10 X11 0 Padding character for adjustment of the data length S Number system character X7 11 Add on code data EAN 13 You can select whether or not to transmi...

Страница 57: ...You can select whether or not to transmit the check digit to the host The conversion to EAN 13 is selectable Conversion to EAN 13 disabled P1 P2 P3 X1 X2 X3 X4 C D Conversion to EAN 13 enabled 0 0 0 0...

Страница 58: ...g the start code to the one preceding the check digit Start stop codes FNC codes or the check digit will not be transmitted Note that FNC1 placed in character positions other than the 1st and 2nd ones...

Страница 59: ...as been correctly transmitted It is therefore important to use the scanner in an environment supporting stable wireless communications Data transmission format Header CRC Terminator DLE STX Number of...

Страница 60: ...mmunications adapter Scanner settings Data packaging mode to host 1 Transfer data packets 2 Analyze packets received 3 Send ACK for a successful transfer NAK for an unsuccessful one Bluetooth enabled...

Страница 61: ...XOR the current CRC value with 0001h 5 Repeat steps 3 and 4 a total of eight times 6 Retrieve the second data byte 13h 7 Repeat steps 3 and 4 a total of eight times 8 Repeat this calculation through t...

Страница 62: ...h link broken Section 3 6 No editing Data extraction mode Data editing ADF script mode Section 7 1 Enable Point scan mode Disable Section 7 2 Double read enabled Period of double read prevention Perio...

Страница 63: ...h 102 key type U K English 102 key type Italian 102 key type Swedish 102 key type Keyboard type Japanese 106 key type Section 9 3 2 Inboard numeric keys Numeric key selection 0 to 9 transmission forma...

Страница 64: ...he data transmission format Enabling this function substitutes E7h to FDh data with the special keys as listed below and transmits the substituted data to the host The Left SHIFT Left CTRL and Left AL...

Страница 65: ...t period for slave to wait for a connection request 30 minutes Section 9 1 Enable Clear the transfer buffer when the Bluetooth link is broken Disable Start operation Bluetooth interface End operation...

Страница 66: ...Items Parameters Defaults Refer to None STX ETX CR LF CR LF TAB ESC ENTER Right CTRL Header User defined None STX ETX CR LF CR LF TAB ESC ENTER Right CTRL Terminator User defined Section 9 4 1 Can be...

Страница 67: ...sion of code ID mark Disable Section 9 4 2 Type 1 DENSO1 Type 2 DENSO2 Type 3 Type 4 Code ID mark User defined Section 9 4 2 Enable in 4 digits Enable in 2 digits Transmission of the number of digits...

Страница 68: ...2 Enable Reading Data Matrix Square Disable Enable Reading Data Matrix Rectangular Disable Section 11 2 See Note 1 QR Code minimum version readable 1 QR Code maximum version readable 1 to 40 40 Micro...

Страница 69: ...1 Enable Reading iQR Code rectangular Disable Section 11 2 iQR code rectangular minimum version readable 1 iQR code rectangular maximum version readable Setting range 1 15 15 Section 11 2 See Note 1...

Страница 70: ...2 Enable EAN 13 transmission of check digit Disable Enable EAN 13 transmission of country code Disable Enable EAN 13 conversion to the ISBN ISSN format Disable Section 11 2 Enable Scanning UPC E Disab...

Страница 71: ...ing Interleaved 2 of 5 Disable Section 11 2 Minimum number of readable digits for Interleaved 2 of 5 4 digits Maximum number of readable digits for Interleaved 2 of 5 2 to 99 digits 99 digits See Note...

Страница 72: ...ote 1 The parameter setting ranges are different from the numbers of digits that the scanner can actually read Can be changed only with the configuration software Code 39 Items Parameters Defaults Ref...

Страница 73: ...smit GS Transmission of FNC1 for Code 128 and GS1 128 EAN 128 User defined Section 11 2 Note 1 Using the QR coded parameter menu enables or disables scanning of both Code 128 and GS1 128 EAN 128 at th...

Страница 74: ...CC A Note 3 Disable Enable Reading UPC EAN Composite with CC B Note 3 Disable Enable Reading EAN 128 Composite with CC A Note 3 Disable Enable Reading EAN 128 Composite with CC B Note 3 Disable Enable...

Страница 75: ...arcode maximum number of readable digits Max 99 digits None Second line barcode Selectable from readable barcodes None Second line barcode character Up to 2 ASCII characters None Second line barcode m...

Страница 76: ...ameters Defaults Refer to Auto off mode Momentary switching mode Trigger switch control mode Alternate switching mode Section 5 1 Enable Break Bluetooth wireless link Disable Section 3 3 Can be change...

Страница 77: ...pprox 4 3 kHz Short approx 60 ms Medium approx 80 ms Beeper beep time Long approx 120 ms High Medium Beeper volume Low Section 8 1 Single beep Scan complete sound Multiple beep Section 8 1 Enable Indi...

Страница 78: ...er Terminator Comma AI split mode Delimiter Tab 09h Section 7 1 Note 1 For details about AI candidates refer to Chapter 7 Section 7 1 1 3 AI table 14 Switching to sleep mode for power saving and auto...

Страница 79: ...Code symbol Three beeps Scanning the All defaults Bar Code symbol from the QR coded parameter menu makes all items in the menu revert to the factory defaults Defaults in the QR coded parameter menu a...

Страница 80: ...Ver 2 1 EDR The 1st connection waits for the connection from a connection target With future connections you can connect by only pressing the trigger switch Only when connecting with the same device...

Страница 81: ...68 Menu control Starting Ending the Setting Procedure and Reverting to Defaults Start setting Start setting Cancel All defaults End setting...

Страница 82: ...he Scan w Bluetooth link broken Bar Code symbol allows the scanner to scan codes with the Bluetooth wireless link broken With this setting selected data transfer with the host computer is impossible S...

Страница 83: ...ers Procedure Non acknowledge mode default ACK NAK mode Header SPP Profile None default STX Header HID Profile None default TAB Enter Terminator SPP Profile None ETX CR default LF CR LF Terminator HID...

Страница 84: ...ype Timeout period for slave to wait for a connection request 2 minutes default 4 minutes 10 minutes 30 minutes Data transmission format Transmission of code ID mark Disable default Enable Transmissio...

Страница 85: ...t Scanning black and white inverted codes Black cells bars on a white background default White cells bars on a black background Auto detection of black and white inverted codes Scanning split QR Code...

Страница 86: ...able default Barcodes Scanning UPC A UPC E EAN 13 and EAN 8 Disable Enable default Scanning Interleaved 2 of 5 Disable Enable with a check digit Check digit transmission disabled Enable without a chec...

Страница 87: ...ning Codabar NW 7 Disable Enable without a check digit default Enable with a check digit Check digit transmission enabled Enable with a check digit Check digit transmission disabled Transmission of st...

Страница 88: ...Check digit transmission enabled Enable with a check digit Check digit transmission disabled Transmission of Start Stop codes for Code 39 Disable default Enable Scanning Code 93 Disable default Enable...

Страница 89: ...Auto off mode default Alternate switching mode Momentary switching mode Buzzer control Disable Enable default Indicator LED Disable Enable default Battery type setting LR6 AA alkaline battery default...

Страница 90: ...77 Remaining battery level check Enable default Disable...

Страница 91: ...eless link is not established Establish the Bluetooth wireless link with the target Bluetooth device Problem 3 Code data not displayed on the computer screen correctly Probable cause What to do The ta...

Страница 92: ...ickel metal hydride battery is used Discharge the AA rechargeable nickel metal hydride battery using the dedicated charger for example and then recharge the battery before using it again For details r...

Страница 93: ...e nickel metal hydride battery 2 A rechargeable nickel metal hydride battery eneloop battery capacity 1900 mAh or equivalent is recommended Make sure that the rechargeable nickel metal hydride battery...

Страница 94: ...ontrol Commands Scanner Host Function B1 B2 B3 Note 1 Note 2 Sound the beeper Within 100 ms from the receipt of any of the B1 B2 and B3 commands the scanner beeps for the period specified below B1 Bee...

Страница 95: ...when the scanner is linked with the configuration software Scan Tune App Response from the scanner Ver n nn mm where n nn mm is version number Ex Ver 1 00 00 and mm is parameter setting version ID Re...

Страница 96: ...es in pairing Once authentication is performed no Bluetooth passkey input is required for the next authentication Local Name Bluetooth Device Name This is a user friendly name for the Bluetooth device...

Страница 97: ...2D Code Handy Scanner SE1 QB User s Manual First Edition November 2014 DENSO WAVE INCORPORATED AUTO ID Division...

Страница 98: ...1 Yoshiike Kusagi Agui cho Chita gun Aichi 470 2297 Japan http www denso wave com...

Отзывы: