background image

1.  OVERVIEW

Matrix

 

II  MF-I

  RFID

  reader  is  used  in  Access  Control  Systems  (ACS)  to  acquire  codes  from 

approached Mifare tokens (cards, key fobs, bracelets etc.) and transmit them to controllers via 
iButton

 

(Dallas Touch Memory) or Wiegand protocols.

A distinctive feature of this model is the support of IronLogic Protected technology, to reliably protect 
cards against cloning (see more details on www.ironlogic.

me

 website). This technology, in addition 

to a Matrix

 

II MF-I 

RFID 

reader requires: a Z-2 USB MF 

Desktop 

reader (with modified firmware), 

IronLogic Object Card(s) and

 

 Mifar

 cards or key fobs to make access cards.

2.  MOUNTING AND CONNECTION

The reader should be mounted on a flat surface, in a place allowing unimpeded proximity card 
access to the reader.
To mount the reader, perform the following operations:
 

1.  Mark and drill the mounting holes of the same size as the reader case holes (Fig.  1)

 

2.  Connect wires to the reader socket, according to layouts on Fig. 4 and Fig. 5.

 

3.  Break out a thin tab in the case from the side where the cable must come out (Fig.  3),

and feed the cable through. When the power is connected to the

 

reader,

 

the red LED will 

                                                                                                       

come up.
 

4.  Mount the reader in the desired place and fix it with screws.

 

5.  Close the reader case openings with plugs (Fig. 2).

Note 1: Do not install readers closer than 10 cm 

one 

from another.

Note 2: To avoid electrical interference when connecting the reader to the controller, a UTP 
cable is recommended, such as CAT5e UTP cable (see Fig. 5).

3. OPERATION

Reader operation without external indication control:
 

1.  When power is supplied, in standby mode (no card in working zone), the LED shines red.

 

2.  On card approach, its number is acquired. If done successfully, the LED turns green for a

    

short time, then switches off, at the same time a short beep also sounds.

 

3.  While the card remains within the reader working zone, the LED stays off.

External indication control for red/green colours of the LEDs and the buzzer is done by shorting 
the corresponding terminal (LED R, LED G, BEEP) to the common ground terminal (GND).
External indication control can be used in parallel with internal indication control; by default, the 
LED and the buzzer are internally controlled. After external indication control signal has been 
activated for one of indication modes (for example, for the LED), that mode becomes externally 
controlled, while the other (in this example, the buzzer) remains under internal control.

Page 1

Matrix

 

II MF-I

 

Mifare 13.56MHz RFID reader 

with connection via iButton / Wiegand-26 protocols 

User Manual

MATRIX II MF-I

www.ironlogic.

me

Содержание Matrix II MF-I

Страница 1: ...red place and fix it with screws 5 Close the reader case openings with plugs Fig 2 Note 1 Do not install readers closer than 10 cm one from another Note 2 To avoid electrical interference when connecting the reader to the controller a UTP cable is recommended such as CAT5e UTP cable see Fig 5 3 OPERATION Reader operation without external indication control 1 When power is supplied in standby mode ...

Страница 2: ...ket terminals 1 Power supply 12 V 2 Common ground 3 DATA0 output 4 DATA1 output 5 LED G external control for green LED 6 LED R external control for red LED 7 BEEP external control for the buzzer To increase buzzer volume remove this sticker Reader ACS Controller iButton DS1990A emulation iButton One time transmission Common Common Common Fig 5 Connecting the reader to ACS controller CONNECTION LAY...

Страница 3: ...R terminals 2 Power on the reader 3 If the LED is blinking red and asignal is sounding the reader is already in Protected Mode 4 If the LED is shining solid red touch the reader with the IronLogic Object card The reader changes LED colour to green and issues a beep for 1 second The Object card has now been stored into reader as a Master card 5 Power off the reader 4 1 2 Storing Object Cards Up to ...

Страница 4: ...ls The reader will confirm the parameter choice and will switch into indicating parameter value 5 Indicating parameter value is similar to indicating parameter number but instead of LED flashing red it s flashing green Parameter values start with the current parameter value 6 To confirm the currently active parameter value connect LED G and GND terminals The new value is stored 7 Power off the rea...

Страница 5: ...Mifare Ultralight Mifare ID Mifare Standard Classic 1K and 4K Card key fobs reading distance 2 6 cm Output protocol iButton Dallas Touch Memory Wiegand Line distance from controller via iButton protocol up to 15 m via Wiegand protocol up to 100 m Card reading status indication visual bicoloured LED audial buzzer Indication control internal external Power supply voltage 12 V DC Current in Card Stan...

Страница 6: ...d production AVS LLC 7 Bobruiskaya street Saint Petersburg 195009 Russian Federation E mail marketing rfenabled com Phone 78122411853 78125421185 www ironlogic ru Authorized representative in the European Union SIA IRONLOGIC 79A Slokas iela LV 1007 Riga Latvia E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me Page 6 MATRIX II MF I www ironlogic me The s...

Отзывы: