49
Chapter 10 Parameters and Defaults
The tables below list the parameters and their defaults. These parameters can be changed with the QR-coded parameter menu
or configuration software (Scan Tune App), except shadowed ones only with the configuration software. When the scanner
leaves the factory, all of these parameters are set to defaults.
(1) Reading modes
Items Parameters
Defaults
Refer
to:
Scan w/ Bluetooth
®
link broken
Scanning with Bluetooth
®
wireless
link broken
Cancel “Scan w/ Bluetooth
®
link broken”
Section 3.6
No editing
Data extraction mode
Data editing
ADF script mode
Section 7.1
Enable
Point scan mode
Disable
Section 7.2
Double-read enabled
Period of double-read prevention
Period of double-read prevention
0.1 to 9.9 sec
1 sec
Section 2.4
(2) Communications modes
Items Parameters
Defaults
Refer
to:
BA
Windows PC/Android
Connection target of scanner
iOS (iPhone/iPad)
Section 3.2
SPP
Profile
HID
Section 3.2
iOS (iPhone/iPad) (HID Profile)
Android (HID Profile)
Android, Windows PC (SPP Profile)
Easy connection setup (See Note 1.)
Windows PC (HID Profile)
Section 3.2
(Note 1):
Can be changed only with the QR-coded parameter menu.
: Can be changed only with the configuration software.