59
Codabar (NW-7)
Items Parameters
Defaults
Refer
to:
Enable, without the check digit
Enable, with a check digit
(Check digit transmission enabled)
Enable, with a check digit
(Check digit transmission disabled)
Reading Codabar (NW-7)
Disable
Section 11.2
Minimum number of readable digits
for Codabar (NW-7)
4 digits
Maximum number of readable digits
for Codabar (NW-7)
3 to 99 digits
(including start/stop codes)
99 digits
(See Note 1.)
Transmit a/b/c/d
Transmit A/B/C/D
Transmission of Start/Stop codes for
Codabar (NW-7)
Disable
Section 11.2
MOD-16
Check digit method for Codabar
(NW-7)
7-check method
Section 11.2
(Note 1) The parameter setting ranges are different from the numbers of digits that the scanner can actually read.
: Can be changed only with the configuration software.
Code 39
Items Parameters
Defaults
Refer
to:
Enable, without the check digit
Enable, with a check digit
(Check digit transmission enabled)
Enable, with a check digit
(Check digit transmission disabled)
Reading Code 39
Disable
Section 11.2
Minimum number of readable digits
for Code 39
1 digit
Maximum number of readable digits
for Code 39
1 to 99 digits
(including start/stop codes)
99 digits
(See Note 1.)
Enable
Transmission of Start/Stop codes for
Code 39
Disable
Section 11.2
Enable
Conversion to FULL ASCII
Disable
Section 11.2
(Note 1) The parameter setting ranges are different from the numbers of digits that the scanner can actually read.