© by DENQBAR GmbH
http://www.denqbar.com
65
4. Check spark plug visually. Dispose of plug in case of
damage or splittered places on the insulator.
5. Measure electrode intervals with an adequate gauge.
The interval should measure 0.6-0.7 mm.
6. Ensure that the sealing ring of the spark plug is in good
condition. Screw in spark plug by hand in order to avoid
tearing of the thread.
7. After screwing the spark plug in, tighten the plug with a
spark plug spanner to compress the sealing ring.
8. Replace plug back tightly onto the spark plug.
9. Replace cover of spark plug.
Attention!
The spark plug must be screwed in tight, otherwise it will get hot and can damage the
generator.
11. Transport and Storage
ATTENTION! Unplug the ignition coil before transport and storage.
In order to avoid fuel leakage during transport and storage, please close the fuel tap and place the
generator at an elevated level.
Warning!
Please pay attention to the following notices during transport:
Do NOT overfill the fuel tank (there should not be any fuel in the upper area of the tank).
Do NOT operate the generator in a truck or in another vehicle, but only on firm ground at a
well-aerated location.
Protect the generator against sun during transport as in a closed container the high
temperatures may emit gases which may catch fire.
Do not transport the generator over uneven streets for longer periods of time. If this is
unavoidable, please empty the fuel tank completely.
Prior to a long-term storage of the generator:
1. Ensure that the storage place is dry and clean.
2. Empty fuel tank completely.