DAEnetIP2 v2
User Manual
21 Apr 2020
- 40 -
Figure 12.10.
Connect the +Vcc and GND wires into the relay board power supply screw
terminal as it is shown on the image above.
6.1. Single power supply. You can supply the kit with single power supply source. In this case it
is 12VDC. If you have 24V relay board version, then you must use 24VDC single power
supply source (
DAEnetIP2 v2
accept from 7.5V - 25V)
+
V
c
c
G
N
D
+12VDC
GND
G
N
D
GND From Flat
Ribbon Cable
IP Controller power
jack
+12VDC
+
-
RJ45
GND
IN
NO C NC
IN
X
~120VAC
IP Controler
Relay Board
Relay
FLAT
RIBBON
CABLE
Power source
Figure 12.11.
Single power supply source.