6.2. 2 Separate power supplies. You can also supply the kit with 2 separate power supply
sources. If the relay board is 24VDC version, then Power supply source 2 (for the relay
board) is 24VDC. Power supply source 1 (for
DAEnetIP2 v2
) may be from 7.5VDC up to
25VDC.
+
V
c
c
G
N
D
+12VDC
GND
G
N
D
GND From Flat
Ribbon Cable
IP Controller power
jack
+12VDC
GND
+
-
RJ45
+12VDC
GND
IN
NO C NC
IN
X
~120VAC
IP Controler
Relay Board
Relay
FLAT
RIBBON
CABLE
Power supply source 1
Power supply source 2
Figure 12.12.
2 separate power supply sources
To calculate what currency rate power supply you need, you will have to make a sum with
DAEnetIP2 v2
current consumption + relay board current consumption.
DAEnetIP2 v2
current
consumption is 50mA at 12VDC. If we have for example 16 channel relay board 12VDC the
consumption is 600mA. So you will need power supply which can provide more than
600+50=650mA at 12VDC. Or 2 supply sources - one >50mA and another >600mA at 12VDC.
You can see the other relay boards current consumptions on their referenced page -
http://www.denkovi.com/category/1/relay-boards.html
. You just have to find your model.
7. Now you can power on the devices (for example plug the adaptor into the electricity network)
8. In case of success you have to see this when you power on the kit
Figure 12.13.
DAEnetIP2 v2
leds. The link led (top) is blinking and the bottom led by default
shows the power on and it is constantly on.