Troubleshooting 

 
 

(Some models may not include all items listed below) 

Symptom Probable 

Cause

Remedy 

No power is being supplied 
to the unit 

1.

 

Trigger Cables connected to the wrong 
place on the machine. 

 

2.

 

Switch on bottom of unit is turned off. 
(Some units may not have a switch) 

3.

 

Power is not cycling on the machine 
properly. 

 

4.

 

Trigger/Power cable is damaged from 
installation. 

1.

 

Check wiring diagram for proper connection and 
contact dish machine manufacturer for correct 
trigger placement. 

2.

 

Make sure switch is turned on. 

 

3.

 

Check with the dish machine manufacturer if all 
power should have been restored to the unit to see 
if there is an issue with the machine. 

4.

 

Turn power to the dish machine off and inspect the 
cable for any possible damage done. 

Pumps are not priming like 
they should be or not 
holding a prime 

1.

 

Hole in the tubing from the chemical 
container to the pump head. 

 

 

2.

 

Hole in the squeeze tube in the pump 
head. 

3.

 

Fitting is not tight on the tubing 

1.

 

Check the tubing from the chemical container to 
the pump head for leaks by feeling the tubing for 
chemical that has leaked out. Replace the tube if 
necessary. 

2.

 

Replace the squeeze tube after inspecting it for a 
possible hole or leak. 

3.

 

Check both the inlet and outlet fitting and tighten if 
necessary to create a good seal. 

Pump over feeding 

1.

 

If in concentration or probe mode, 
Pulse feed may be turned off. 

2.

 

If in concentration or probe mode, 
probe cable may not be connected 
properly. 

3.

 

If a probe is being used, scale could be 
built up on the probe. 

4.

 

Dip switch is on High Range and pot 
is set for low range. 

1. Check the dip switches and turn the pulse feed on.

 

2.

 

Check the probe cable connection points and make 
sure it is connected properly. 

 

3.

 

Clean Probe. 

 

4.

 

Switch dip switch to low range or set pot to needed 
setting. 

Pump under feeding 

1.

 

If in concentration or probe mode, the 
probe cable may be shorted. 

2.

 

If a probe is being used, scale would 
be build up on the probe. 

3.

 

Dip switch is on low range and pot is 
set for high range. 

1.

 

Check the probe cable for any possible shorts and 
correct the issue where necessary. 

2.

 

Clean Probe. 

 

3.

 

Check the dip switches and switch to high range if 
necessary or set pot to needed setting. 

Rinse/Sanitizer pump not 
running 

1. Speed turned off.

1. Check the pot to see the speed setting and make

sure it is turned to the proper setting. 

 

Warranty  

Merchandise Returns 

No Merchandise will be Returned for Credit Without DEMA’S Written Permission. Returned Merchandise 
Authorization Number is Required in Advance of Return. 

 

Product Warranty 

DEMA products are warranted against defective material and workmanship under normal use and service for 
one year from the date of manufacture. This limited warranty does not apply to any products that have a  
normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, or 
misapplication. Rubber and synthetic rubber parts such as “o”-rings, diaphragms, PVC tubing, and gaskets are 
considered expendable and are not covered under warranty.  This warranty is extended only to the original 
buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty is 
void. 

Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them 
to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability 
for damages. Return merchandise authorization number must be granted in advance of returned units for repair 
or replacement (See “Merchandise Returns” above). 

Содержание NITRO EXPRESS

Страница 1: ...tee is t isconsin and an ROTECTIVE C UCTS Nitro Ex Chemical enser designed h machine Pro meet all applic vincial or other ectrical contrac ctrician al plumbing co to be installed w ny other state t C...

Страница 2: ...KYNAR X X 81 16 1 TIE WRAPS 8 LONG 5 5 8 8 I974 INSTRUCTION SHEET X X X X Operational Requirements For indoor use only Trigger Signal Inputs 115 230VAC 50 60 Hz 1 5A Motors Solenoid Valves 24VDC Dete...

Страница 3: ...PRODUCT DETERGENT RINSE 81 316 3 CONTROL BOARD NITRO EXPRESS WITH SANITIZER 3 PRODUCT 3 81 316 4 NITRO EXP DETERGENT PUMP HEAD AND MOTOR CONV AND REPLACEMENT KIT 81 316 10 NITRO NITRO EXPRESS DETERGE...

Страница 4: ...must be way from heatin ulkhead fitting g the wash tank ting 904 8T i d follow the m ing 904 8KY a tap is not pro e Nitro Expre measure the leng g 25 68 20 is 1 which is clea uired and if des eded to...

Страница 5: ...ound connection on the dish machine as recommended by the dish machine manufacturer If there is ever any question about the connection to the dish machine please check with the dish machine manufactur...

Страница 6: ...5 6 3 7 2 8 1 9 0 10 Detergent 4 5 6 3 7 2 8 1 9 0 10 Initial Detergent Charge The detergent knob sets the time the detergent pump will run or detergent valve will remain open during an initial charge...

Страница 7: ...and high switch 3 sets the range Probe Concentration Configuration The settings for the probe configuration are the same when the dispenser is being used in door or conveyor mode 4 5 6 3 7 2 8 Deterg...

Страница 8: ...connection points and make sure it is connected properly 3 Clean Probe 4 Switch dip switch to low range or set pot to needed setting Pump under feeding 1 If in concentration or probe mode the probe ca...

Отзывы: