I-974
Rev. J-43816
Page 2 of 8
3/23/18
Packing List
X = included in kit
Part Number
Description
NE.DL.A
NE.LL.A
NE.DLL.A
NE.LLL.A
904.8T
RINSE CHECK VALVE ¼” OD TEFLON BALL
X
X
X
X
80.55
LIQUID DETERGENT FEED INJECTION ELBOW
X
X
81.312.1
SPLIT PICK UP TUBE STIFFENER
1
2
2
3
25.68.20
20 FT ¼” OD LDPE TUBING
X
X
X
X
C.12B
CONDUCTIVITY CELL
X
X
X
X
100.12.SV1
VINYL RINSE TUBING
X
X
X
X
58.5
OVERFLOW ELBOW KIT – DRY DETERGENT
X
X
904.8KY
RINSE CHECK VALVE ¼” COMP X 1/8” NPT KYNAR
X
X
81.16.1
TIE WRAPS 8” LONG
5
5
8
8
I974
INSTRUCTION SHEET
X
X
X
X
Operational Requirements
For indoor use only
Trigger Signal Inputs
115/230VAC 50/60 Hz 1.5A
Motors/Solenoid Valves
24VDC
Detergent Pump Rate
6oz/min (180ml/min)
Rinse/Sanitizer Pump Rate
1.3oz/min (40ml/min)
Operating Temp
4-30°C
40-100°F
Case Material
ABS
The integrity and operational characteristics of this unit are not guaranteed outside the above
mentioned parameters. Use of this unit outside of these parameters nullifies warranty.
This unit will only accept up to 265 VAC. It cannot accept over this amount. If more than 265
VAC is supplied to this unit, critical damage will occur.
Overall Size