NO.5 Function List
15
limit
P012
Reserve
P013
Parameter resetting
8 restore ex-factory value
00
╳
P014
Acceleration time I
0.1-6500.0s
*
○
P015
Deceleration time I
0.1-6500.0s
*
○
P016
Acceleration time II
0.1-6500.0s
*
○
P017
Deceleration time II
0.1-6500.0s
*
○
P018
Acceleration time III
0.1-6500.0s
*
○
P019
Deceleration time III
0.1-6500.0s
*
○
P020
Acceleration time IV
0.1-6500.0s
*
○
P021
Deceleration time IV
0.1-6500.0s
*
○
P022
Reserve
5.2 Application function parameters
Function
code
Name of function
Setting range and data content
Ex-factory
value
Alteration
P023
Reverse prohibit
0: Reverse prohibit
1: Reverse allow
1
╳
P024
Stop key is valid or not
0: STOP invalid
1: STOP valid
1
╳
P025
Start mode
0: Start from starting frequency
1: Frequency tracking start
0
╳
P026
Stop mode
0: Decelerate stop
1: Free running stop
0
╳
P027
Starting frequency
0.10-30.0 Hz
0.5
╳
P028
Stop frequency
0.10-30.0 Hz
0.5
╳
P029
Start braking time
0.0-25.0s
0.0
╳
P030
Stop braking time
0.0-25.0s
0.0
╳
P031
DC braking level
0.0-20.0%
2.0
╳
P032
Frequency tracking
time
0.1-20.0s
5.0
╳
P033
Current tracking
frequency level
0-200%
150
╳
P034
Voltage rise time
during frequency
tracking
0 .1-10.0s
0.5
○
P035-P040
Reserve
P041
Carrier frequency
0-15
*
╳