NO.8 Selection and Configuration of Peripheral Facilities
84
2. Brake resistor configuration
Model of inverter
Specification of brake
resistor
Brake torque
10%ED
Dedicated motor
KW
W
Ω
D5M-0.4T2-1A
80
200
125
0.4
D5M-0.75T2-1A
100
200
125
0.75
D5M-1.5T2-1A
300
100
125
1.5
D5M-2.2T2-1A
300
70
125
2.2
D5M-3.7T2-1A
390
40
125
3.7
D5M-5.5T2-1A
520
33
125
5.5
D5M-0.4T4-1A
80
750
125
0.4
D5M-0.75T4-1A
80
750
125
0.75
D5M-1.5T4-1A
300
400
125
1.5
D5M-2.2T4-1A
300
250
125
2.2
D5M-3.7T4-1A
400
150
125
3.7
D5M- 5.5T4-1A
500
100
125
5.5
D5M-7.5T4-1A
1000
75
125
7.5
D5M-11T4-1A
1000
50
125
11
D5M-15T4-1A
1500
40
125
15
D5M-18.5T4-1A
4800
32
125
18.5
[Note] 1) Please select resistance value and service power set by our company;
2) Our company shall assume no responsibility for the damage of inverter or other
devices induced by the application of brake resistor and brake unit which are not
provided by our company;
3) Be sure to take the safety and inflammability of the environment for installation of
brake resistor and make the distance between it and inverter up to 100mm at least;
4) For changing resistance and power number, please contact local dealer;
5) In need of brake resistor, separately order brake resistor, and contact local dealer
for details;
6) It is necessary to install brake unit if quick braking is required of the inverter over
11KW.