background image

 

 

 

15)  FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE. A SPARK 

NEAR BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK OF A 
SPARK NEAR BATTERY: 

a)  Position ac and dc cords to reduce risk of damage by hood, door, or moving engine 

part. 

b)  Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to 

persons. 

c) 

Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually has 
larger diameter than NEGATIVE (NEG, N,–) post. 

d)  Determine which post of battery is grounded (connected) to the chassis. If negative 

post is grounded to chassis (as in most vehicles), see (e). If positive post is 
grounded to the chassis, see (f). 

e)  For negative-grounded vehicle, connect POSITIVE (RED) clip from battery charger 

to POSITIVE (POS, P, +) ungrounded post of battery first. Then connect NEGATIVE 
(BLACK) clip to vehicle chassis or engine block away from battery. Do not connect 
clip to carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gage 
metal part of the frame or engine block. 

f) 

For positive-grounded vehicle, connect NEGATIVE (BLACK) clip from battery 
charger to NEGATIVE (NEG, N, –) ungrounded post of battery first. Then connect 
POSITIVE (RED) clip to vehicle chassis or engine block away from battery. Do not 
connect clip to carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy 
gage metal part of the frame or engine block; 

g)  Connect charger AC supply cord to electric outlet; and 
h)  When disconnecting charger, turn switches to off, disconnect AC cord, remove clip 

from vehicle chassis, and then remove clip from battery terminal. 

i) 

See operating instructions for length of charge information. 

16)  FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE. A SPARK NEAR 

THE BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK OF A 
SPARK NEAR BATTERY: 

a)  Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually has a 

larger diameter than NEGATIVE (NEG, N, –) post. 

b)  Attach at least a 24-inch-long 6-gauge (AWG) insulated battery cable to NEGATIVE 

(NEG, N, –) battery post. 

c) 

Connect POSITIVE (RED) charger clip to POSITIVE (POS, P, +) post of battery. 

d)  Position yourself and free end of cable as far away from battery as possible – then 

connect NEGATIVE (BLACK) charger clip to free end of cable. 

e)  Do not face battery when making final connection. 
f) 

When disconnecting charger, always do so in reverse sequence of connecting 
procedure and break first connection while as far away from battery as practical. 

g)  A marine (boat) battery must be removed and charged on shore. To charge it on 

board requires equipment specially designed for marine use. 

 

 

 

 
GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS –  

Charger should be grounded to reduce risk of electric shock. Charger is equipped with an 
electric cord having an equipment-grounding conductor and a grounding plug. The plug must 
be plugged into an outlet that is properly installed and grounded in accordance with all local 
codes and ordinances. 
 

DANGER –

 Never alter AC cord or plug provided – if it will not fit outlet, have proper outlet 

installed by a qualified electrician. Improper connection can result in a risk of an electric shock. 
 
This battery charger is for use on a nominal 120-volt circuit, and has a grounding plug that 
looks like the plug illustrated in sketch A in Figure 1. A temporary adapter, which looks like the 
adapter illustrated in sketches B and C, may be used to connect this plug to a two-pole 
receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary 
adapter should be used only until a properly grounded outlet can be installed by a qualified 
electrician. 
 

DANGER –

 Before using adapter as illustrated, be certain that center screw of outlet plate is 

grounded. The green-colored rigid ear or lug extending from adapter must be connected to a 
properly grounded outlet– make certain it is grounded. If necessary, replace original outlet 
cover plate screw with a longer screw that will secure adapter ear or lug to outlet cover plate 
and make ground connection to grounded outlet.

 

 
NOTE: 
USE OF AN ADAPTER IS NOT ALLOWED IN CANADA. IF A GROUNDING TYPE 
RECEPTACLE IS NOT AVAILABLE, DO NOT USE THIS APPLIANCE UNTIL THE 
PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN 

 
 
 
 
 
 
 

 

This symbol indicates separate collection for electrical and 

electronic equipment

 

Figure 1

GROUNDING

PIN

(A)

(B)

(C)

GROUNDING
MEANS

ADAPTER

METAL SCREW

COVER OF GROUNDED

OUTLET BOX

Содержание Battery Tender

Страница 1: ...attery d If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eye immediately flood eye with running cold water for at least 10 minutes and get medical attention immediately e NEVER smoke or allow a spark or flame in vicinity of battery or engine f Be extra cautious to reduce risk of dropping a metal tool onto battery It might spark or short circuit battery...

Страница 2: ...and free end of cable as far away from battery as possible then connect NEGATIVE BLACK charger clip to free end of cable e Do not face battery when making final connection f When disconnecting charger always do so in reverse sequence of connecting procedure and break first connection while as far away from battery as practical g A marine boat battery must be removed and charged on shore To charge ...

Страница 3: ... pressing the BATTERY button The battery type must be selected once the charger has AC power applied and before the charger is connected to the battery Once the charger has AC power and is also connected to the battery the battery type selection cannot be changed In order to begin a new charge cycle reset the charger by disconnecting it from the AC supply as well as the wrong or defective battery ...

Страница 4: ...d AGM battery or 6 volts from a LiFePO4 battery It must be connected to a battery with the correct polarity before it will start charging a battery Therefore if you plug the AC power cord into an AC power outlet and if the output alligator clips or ring terminals are not connected to a battery and if you touch the alligator clips or ring terminals together there will be no electrical spark NOTE TH...

Страница 5: ... the battery on charge until the green light is solid GREEN LIGHT ON STEADY Green LED When the green READY LED burns steady the charge is complete and the battery can be returned to service if necessary It can also stay connected to maintain the battery for an indefinite period of time 10 Troubleshoot Guide 1 If the charger does not turn on and none of the LED s illuminate a Check to make sure the...

Страница 6: ...IENT DES INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ ET LE FONCTIONNEMENT 1 IL EST DANGEREUX DE TRAVAILLER A PROXIMITÉ D UNE BATTERIE AU PLOMB LES BATTERIES PRODUISENT DES GAZ EXPLOSIFS EN SERVICE NORMAL IL EST AUSSI IMPORTANT DE TOUJOURS RELIRE LES INSTRUCTIONS AVANT D UTILISER LE CHARGEUR ET DE LES SUIVRE À LA LETTRE 2 POUR RÉDUIRE LE RISQUE D EXPLOSION LIRE CES INSTRUCTIONS ET CELLES QUI FI...

Страница 7: ...R LOIN DE LA BATTERIE NE PAS RACCORDER LA PINCE AU CARBURATEUR AUX CANALISATIONS D ESSENCE NI AUX PIÈCES DE LA CARROSSERIE EN TÔLE RACCORDER À UNE PIÈCE DU CADRE OU DU MOTEUR EN TÔLE DE FORTE ÉPAISSEUR 14 f SI LA BORNE POSITIVE EST MISE À LA MASSE RACCORDER LA PINCE NÉGATIVE NOIRE DU CHARGEUR À LA BORNE NÉGATIVE NÉG N NON MISE À LA MASSE DE LA BATTERIE RACCORDER LA PINCE POSITIVE ROUGE AU CHÂSSIS ...

Страница 8: ...arrer Pour commencer un nouveau cycle de charge réinitialiser le chargeur en le déconnectant de l alimentation c a ainsi que la mauvaise batterie ou la batterie défectueuse pendant 7 à 10 secondes Reconnecter l alimentation c a et le chargeur sera prêt pour un nouveau cycle de charge Bouton de sélection de type composition chimique de la batterie Changer le type la composition chimique de la batte...

Страница 9: ...rgeur Battery Tender surveille et maintient automatiquement la batterie à pleine charge 18 ATTENTION Le CHARGEUR Battery Tender COMPREND UN CIRCUIT SANS ÉTINCELLE Les pinces crocodile ou les cosses à anneau de sortie ne produisent pas d étincelles lorsqu elles se touchent Le chargeur Battery Tender ne produit pas de tension de sortie tant qu il n a pas détecté au moins 2 volts en provenance de la ...

Страница 10: ...le laisser la batterie en charge jusqu à ce que le voyant vert reste allumé en continu VOYANT VERT FIXE Voyant DEL vert Lorsque le voyant vert READY Prêt reste allumé en continu la charge est terminée et la batterie peut être utilisée si nécessaire Elle peut également rester connectée pour maintenir la batterie pendant une période de temps indéfinie 20 Guide de dépannage 1 Si le chargeur ne se met...

Страница 11: ...ences nuisibles à la réception des ondes de radio télévision ce qui peut être déterminé en mettant l appareil hors tension puis sous tension L utilisateur est invité à essayer de remédier à ces interférences par une ou plusieurs des mesures suivantes Réorienter ou déplacer l antenne de réception Augmenter la distance entre l appareil et le récepteur Connecter l appareil sur une prise située sur un...