Delta VIS100-30G12D Скачать руководство пользователя страница 6

1

 

部件名稱及規格

   

VIS100 Vision Sensor Operating Manual 

1-3 

1.3 Camera and Lens                                                

VIS100 Sensor includes 0.3M pixel CMOS sensor, lens is the 8mm (M12, C mount) specification. 

Before selecting the lens, please confirm the field of view and working distance between the lens and test 

object. Refer to the table below for a suitable lens. 

Field of view 

(mm) 

Horizontal 

(H)*Vertical (V) 

Focal 

length 

8mm 

Focal 

length 

12mm

 

Focal 

length 

16mm

 

Focal 

length 

25mm

 

Focal 

length 

35mm

 

Focal 

length 

50mm

 

Resolution 

um/pixel 

Dis. 

Dis. 

Dis. 

Dis. 

Dis. 

Dis. 

640 

* 480 

1024

* 768 

1000(H)*750(V) 

1667 

 

 

 

 

 

 

 

 

 

 

1562 

977 

800(H)*600(V) 

1333 

2013 

 

 

 

 

 

 

 

 

1250 

781 

600(H)*450(V) 

1000 

1513 

2015 

 

 

 

 

 

 

938 

586 

500(H)*375(V) 

833 

1263 

1683 

 

 

 

 

 

 

781 

488 

400(H)*300(V) 

667 

1013 

1348 

2181 

 

 

 

 

625 

391 

350(H)*263(V) 

583 

888 

1181 

1906 

 

 

 

 

547 

342 

300(H)*225(V) 

500 

763 

1014 

1631 

2253 

 

 

469 

293 

250(H)*188(V) 

417 

638 

847 

1356 

1878 

 

 

391 

244 

225(H)*169(V) 

375 

575 

764 

1218 

1690 

 

 

352 

220 

200(H)*150(V) 

333 

513 

681 

1081 

1503 

2241 

313 

195 

175(H)*131(V) 

292 

450 

597 

943 

1315 

1963 

273 

171 

150(H)*113(V) 

244 

389 

514 

806 

1128 

1686 

234 

146 

140(H)*105(V) 

228 

362 

480 

751 

1053 

1575 

219 

137 

130(H)*98(V) 

210 

334 

444 

696 

978 

1464 

203 

127 

120(H)*90(V) 

193 

307 

407 

641 

903 

1353 

188 

117 

110(H)*83(V) 

175 

280 

371 

586 

828 

1242 

172 

107 

100(H)*75(V) 

158 

253 

336 

532 

753 

1131 

156 

97 

90(H)*68(V) 

142 

227 

300 

477 

678 

1020 

141 

88 

80(H)*60(V) 

124 

200 

265 

423 

603 

909 

125 

78 

75(H)*56(V) 

115 

0.5 

183 

247 

397 

565 

853 

117 

73 

70(H)*53(V) 

107 

0.5 

176 

230 

370 

528 

798 

109 

68 

65(H)*49(V) 

98 

0.5 

160 

212 

344 

490 

742 

102 

63 

60(H)*45(V) 

90 

0.5 

147 

193 

316 

453 

687 

94 

59 

55(H)*41(V) 

81 

0.5 

133 

0.5 

175 

290 

417 

631 

86 

54 

50(H)*38(V) 

72 

120 

0.5 

158 

262 

378 

576 

78 

48.8 

45(H)*34(V) 

63 

106 

0.5 

142 

1.5 

235 

341 

520 

70 

43.9 

40(H)*30(V) 

55 

93 

123 

1.5 

208 

304 

465 

63 

39.1 

35(H)*26(V) 

47 

79 

108 

1.5 

183 

268 

409 

55 

34.2 

32.5(H)*24.4(V) 

42 

72 

99 

168 

247 

382 

51 

31.7 

30.0(H)*22.5(V) 

37 

1.5 

66 

1.5 

89 

153 

229 

354 

46.9 

29.3 

Содержание VIS100-30G12D

Страница 1: ...Installation 2 2 Chapter 3 Basic Operation 3 1 Application Names and Functions 3 1 3 2 GUI 3 3 3 2 1 Main Page 3 4 3 3 2 Menu Page 3 5 3 3 3 Language 3 8 3 3 4 Information Page 3 9 3 3 5 Statistics Pa...

Страница 2: ...s 5 1 Region of Interest ROI 5 1 5 2 Filters 5 2 5 3 Barcode 5 3 5 3 1 1D Barcode 5 3 5 3 2 Data Matrix Code DMC 5 4 5 3 3 QR Code 5 6 5 3 4 Micro QR Code 5 7 5 4 Blob 5 9 Chapter 6 Troubleshooting 6...

Страница 3: ...touch the terminals or connect the wires while system power is turned on as this runs the risk of electric shock 3 Please do not disassemble or modify the internal components of the controller 4 Keep...

Страница 4: ...kaging and Optional Parts A complete vision system requires the following basic components 1 Vision sensor unit and 0 4 m cable 2 Lens optional first set is included with the 8mm lens 1 1 1 Unit Packa...

Страница 5: ...tion 0 3M pixel 640 Horizontal 480 Vertical 90fps Exposure 200 65535 us Lens mount M12 Memory DDR3 512MB 4GB Flash Inspection window Inspection item Code Reader Blob ROI Type Rectangle Circle Pre proc...

Страница 6: ...0 681 0 1081 0 1503 0 2241 0 313 195 175 H 131 V 292 0 450 0 597 0 943 0 1315 0 1963 0 273 171 150 H 113 V 244 0 389 0 514 0 806 0 1128 0 1686 0 234 146 140 H 105 V 228 0 362 0 480 0 751 0 1053 0 1575...

Страница 7: ...49 9 85 15 145 10 17 2 10 7 10 0 H 7 5 V 13 5 19 8 44 10 77 15 133 10 15 6 9 77 9 0 H 6 75 V 11 6 16 9 39 11 68 15 122 15 14 1 8 79 8 0 H 6 00 V 8 7 13 10 34 13 63 20 111 20 12 5 7 81 7 5 H 5 63 V 8 7...

Страница 8: ...nput Output I O Terminal Block Wiring the Sensor Connect and secure the I O Cable to the I O Cable connector located on the bottom of the Vision Sensor The following table lists the I O Cable signal c...

Страница 9: ...powered on The grounding wire should be at minimum length using the regulated wire gauge The grounding resistance must be under 100 Please ground the grounding terminal using the third method Do not...

Страница 10: ...manufacture date Statistics Displays statistics for the total camera triggered times total code read times total code unread times total pass verification and failed verification times Home Returns t...

Страница 11: ...for matching a pre defined pattern Mapping 1 8 Mapping tool for mapping the image with a checkerboard pattern Configuration Functions Icon Name Inspection Tool Camera settings 1 Configures camera imag...

Страница 12: ...mode appears according to your license 7 Export settings are available for PC browsers which support HTML5 API BLOB 8 You need a Complete license or Alignment license for this function 3 2 GUI Both Sm...

Страница 13: ...nu and Statistics Window width between 1000 px and 1300 px shows the Menu on the left side Window width larger than 1300 px shows the Menu on the left and Statistics on the right of the window 3 2 1 M...

Страница 14: ...rd the menu or menu button will show on PC 1 The menu is on the left side of the screen when the browser is in full screen width 2 The menu contains inspection tools that you can use in the process ac...

Страница 15: ...ision Sensor Operating Manual 3 6 3 The Configuration page contains all the camera settings Smartphone 1 To access the menu tap the top left button left figure on the screen and the menu right figure...

Страница 16: ...7 2 The Application menu contains the inspection tools that you can use to process an image according to your license To activate an application select the check box next to the tool check barcode as...

Страница 17: ...3 Language The application supports four languages Simplified Chinese English Japanese Korean PC You change the language by clicking the Language button at the top left of the menu page Smartphone You...

Страница 18: ...ure date DD MM YYYY format 3 2 5 Statistics Page The Statistics page contains the following information 1 Total Triggered Total number of times the camera is triggered 2 Total Read Total number of tim...

Страница 19: ...e default camera IP address for camera from Inspiraz Technology Name Address IP 192 168 1 10 Mask 255 255 255 0 Gateway 192 168 1 1 DNS 192 168 1 1 4 1 2 Open the Application You must use a web browse...

Страница 20: ...ogin page 3 Enter the Username and Password 4 Click Login Default Username admin Default Password admin 4 1 4 Basic Operation Live camera Start Click once to run the live camera Stop Click again or cl...

Страница 21: ...ttings to run the camera after rebooting Output Image Outputs the processed image after you open the browser and enter the camera IP Crop Image Auto crops the image using fixed size Auto or a custom s...

Страница 22: ...ation There are three types of communication 1 I O Only two output terminals available 2 UDP 3 TCP IP The Communication settings are separated into two parts 1 I O Setting Enabled I O Features Enable...

Страница 23: ...C TCP IP Use the TCP client to send the result data support to trigger the camera IP Destination TCP server IP address Port Destination TCP server port number port 4000 for the comm trigger Please use...

Страница 24: ...d a new user Username Enter the new username Password Enter the new user password Confirm Password Enter the password again to confirm Delete User Select Delete User to delete a user Note that you can...

Страница 25: ...the current user Confirm Password Enter the password again to confirm 4 2 4 Mode The VIS100 application can operate in either Code Reader or Blob mode Use Mode Selection to switch between the 2d code...

Страница 26: ...teway address DNS Dynamic name server address MAC Device MAC address 4 2 6 Export Import Settings Set the export settings import settings and export image settings Export settings Click to set the exp...

Страница 27: ...h inspection tool has 3 types of ROIs 1 Complete Uses the whole image for the process 2 Rectangle Defines a rectangle ROI that you can rotate and resize 3 Circle Defines a circle ROI that you can rota...

Страница 28: ...th various square or circular masks Range Highlights and outlines contour edges Mirror Mirrors an image across its horizontal or vertical axis Rotate Rotates an image by a defined angle Invert Inverts...

Страница 29: ...de function to read and decode barcodes You can improve the reading speed by reducing the search area using an ROI and through other settings Number of code Defines the maximum number of codes availab...

Страница 30: ...Standard Fastest for finding codes Enhanced More accurate in finding codes but slower than Standard mode Maximum Most accurate in finding codes but slowest compared to other modes Mirror Type Defines...

Страница 31: ...k box to compare the decoded barcode with a defined reference For multiple code content add a delimiter between two different results for example 01234567 7654321 The result is OK if the code matches...

Страница 32: ...ds in the inspection process Code Length Select the check box to check the length of the decoded barcode The result is OK if the code length matches NG if the code length does not match Code Quality S...

Страница 33: ...pixel size of the modules Recognition Mode Standard Fastest for finding codes Enhanced More accurate in finding codes but slower than Standard mode Maximum Most accurate in finding codes but slowest...

Страница 34: ...ntent add a delimiter between two different results for example 01234567 7654321 The result is OK if the code matches NG if the code does not match Expert Mode Recognition Mode Standard Fastest for fi...

Страница 35: ...scale threshold are marked If too many objects are found use additional conditions to limit the number of detected objects Threshold Finds the gray value between the minimum and maximum pixel values i...

Страница 36: ...utside this range Width Filter Select the check box to define the minimum and maximum width size of detected objects The function ignores values outside this range Height Filter Select the check box t...

Страница 37: ...tions to resolve the problem Reboot the camera Delete the web browser cache and cookies Go to the Information pages to verify the Version ID License and Date If no information is listed for those valu...

Отзывы: