Chapter 4 Inspection Setting Process
VIS100
Vision Sensor Operating Manual
4-4
Trigger
: Sets the camera trigger, communication trigger will descript in 4.2.2.
Hardware
: Shows the trigger timeout, delay and signal edge.
Continuous
: Sets the cycle time for continuous internal trigger.
Light
: Sets the camera light (depends on the camera model).
4.2.2 Communication
There are three types of communication.
1)
I/O: Only two output terminals available.
2)
UDP
3)
TCP/IP
The Communication settings are separated into two parts.
1)
I/O Setting
•
Enabled I/O Features
: Enable the selected
Outputs 2-5
.
•
Output Camera Ready
:
Signal to I/O when camera is ready.
•
Output Camera Busy
: Signal to I/O when camera is processing.
•
Result(P/F):
This is usually based on the tests in the inspection tools, such as the Blob
Count
content
or the Barcode
Code content
.
OK
: Signal to I/O when condition passes.
NG
: Signal to I/O when condition failed.