Chapter 4 Inspection Setting Process
VIS100 Vision Sensor Operating Manual
4-5
2)
Comm. Setting
•
Disable
: Disable communication over the network.
•
UDP
:
Use the UDP client to the send result data .(no error checking)
IP
:
Destination UDP server IP address.
Port
: Destination UDP server port number.
Send header
: Send special header (for example<barcode>) before sending the result
Header
(ASCII)
:
Setting the Header word. (DEC)
Separator (ASCII):
Setting the Separator word. (DEC)
EOF (ASCII)
: Setting the Separator word. (DEC)
•
TCP/IP
: Use the TCP client to send the result data, support to trigger the camera.
IP
: Destination TCP server IP address.
Port:
Destination TCP server port number (port 4000 for the comm. trigger).
Please use TCP Client mode in the third party software to connect the camera(VIS as TCP
Server), then send the following string to trigger camera:
◦
Run
: Run#003
◦
Run once
: Once#003
◦
Stop
: Stop#003
Send Image
: Send the captured image (BMP) over TCP.
◦
Always
: Always send the image.
◦
OK
: Send the image when the result is OK.
◦
NG
: Send the image when the result is NG.
◦
Disable
:
Disable sending images.
Header (ASCII)
: Setting the Header word. (DEC)
▪
Separator (ASCII)
:
Setting the Separator word. (DEC)
▪
EOF (ASCII)
: Setting the EOF word. (DEC)