Example 6:
In this example, a negative bias is used to provide a noise margin. Also a potentiometer frequency
gain is used to allow the Maximum Output Frequency to be reached.
Potentiometer scale
Max. operation frequency
Potentiometer bias frequency
Bias polarity
Potentiometer frequency gain
Forward motion only
Max. operation frequency
Pr.01-00
It's 0Hz
within
this range
Factory set ting
Hz
27
60
0
0V
10V
60Hz
0Hz
0V
10V
1V
54Hz
Pr.01-00=60Hz
4-00=6Hz
4-01=1
4-02=110%
4-03=2
Pr.0
Pr.0
Pr.0
Pr.0
Pr.04-02
(1-
=
)X 100%
Pr.04-00
Pr.01-00
Negat ive
bias 6Hz
Gain Adjustment
Calculation of G ain
Example 7:
This example with FWD/REV application can be easily used with system for the complicated
application. When this application is set, external FWD and REV command will auto be invalid.
Potentiometer scale
Max. operation frequency
Potentiometer bias frequency
Bias polarity
Potentiometer frequency gain
Forward motion only
Max. operation frequency
Pr.01-00
Pr.01-00=60Hz
4-00=30Hz
4-01=1
4-02=0%
4-03=1
Pr.0
Pr.0
Pr.0
Pr.0
60Hz
0Hz
0V
10V
5V
30Hz
30Hz
60Hz
Hz
60
0
0V
10V
60
FW D
REV
Example 8:
In this example, the option of anti-slope is shown. Anti-slope is used in an application where control
of pressure, temperature, or flow is needed. Under a high pressure or flow situation, a sensor will
generate a large signal. With anti-slope enable, the large signal will slow or stop the AC drive.
Please notice that it can’t change the direction in this application, it only can change the AC drive to
reverse running.
Potentiometer scale
Max. operation frequency
Potentiometer bias frequency
Bias polarity
Potentiometer frequency gain
Reverse mot ion enable
Max. operation frequency
Pr.01-00
Hz
30
0
60
0V
10V
60Hz
0Hz
0V
10V
Pr.01-00=60Hz
4-00=60Hz
4-01=1
4-02=100%
4-03=1
Pr.0
Pr.0
Pr.0
Pr.0
anti-slope
Factory set ting
04-04
Multi-function Input Terminal (M0, M1)
Settings
0 to 20
Factory Setting: 1
Содержание VFD-L-I Series
Страница 1: ...PLC1 ir...
Страница 2: ......
Страница 3: ......
Страница 5: ...This page intentionally left blank...
Страница 91: ...Chapter 6 Troubleshooting VFD L I Series 6 6 Revision July 2009 SW V1 1 This page intentionally left blank...
Страница 99: ...Appendix A Specifications VFD L I Series A 2 Revision July 2009 SW V1 1 This page intentionally left blank...