Chapter 4 Parameters
|
VFD-L-I Series
4-4
Revision July 2009, SW V1.1
Pr. Explanation
Settings
Factory
Setting
NOTE
02-06 Line Start Lockout
0: Disable
1: Enable
1
Group 3 Output Function Parameters
Pr. Explanation
Settings
Factory
Setting
NOTE
03-00 Desired Frequency Attained
1.00 to 400.00 Hz
1.00
03-01 Terminal Count Value
0 to 999
0
03-02 Preliminary Count Value
0 to 999
0
03-03
Multi-Function Output Terminal
(Relay)
0: No Function
1: AC Drive Operational
2: Master Frequency Attained
3: Zero Speed
4: Over Torque Detection
5: Base-Block (B.B.) Indication
6: Low-Voltage Indication
7: Operation Mode Indication
8: Fault Indication
9: Desired Frequency Attained
10: PLC Program Running
11: PLC Program Step Completed
12: PLC Program Completed
13: PLC Program Operation Paused
14: Terminal Count Value Attained
15: Preliminary Count Value
Attained
16: AC Motor Drive Ready
8
Group 4 Input Function Parameters
Pr. Explanation
Settings
Factory
Setting
NOTE
04-00 Potentiometer Bias Frequency
0.00 to 350.00Hz
0.00
04-01
Potentiometer Bias
Polarity
0: Positive Bias
1: Negative Bias
0
04-02 Potentiometer Frequency Gain
1 to 200 %
100
04-03
Potentiometer Reverse Motion
Enable
0: No Function
1: Reverse Motion enabled
2: Reverse Motion disabled
0