Chapter 4 Parameters
|
VFD-L-I Series
Revision July 2009, SW V1.1
4-21
Setting
Function
Description
13
PLC Operation Paused
the output will be activated when PLC operation is
paused.
14
Terminal Count Value
Attained
the output will be activated when counter reaches
Terminal Count Value(Pr.03-01).
15
Preliminary Counter Value
Attained
the output will be activated when counter reaches
Preliminary Count Value(Pr.03-02).
16
AC Motor Drive Ready