Alarm Condition
Code
Description
Suggested Action
HW Fault M1
01
Hardware error from the left module
Take all safety precaution, and
then check if the mains voltage
that is in specification. Turn on
the output power with a dummy
load to ensure if it is under
normal operation.
HW Fault M2
02
Hardware error from the right
module
Take all safety precaution, and
then check if the mains voltage
that is in specification. Turn on
the output power with a dummy
load to ensure if it is under
normal operation.
SW OVP
03
Output over voltage
Take all safety precaution, and
then check if the mains voltage
that is in specification. Turn on
the output power with a dummy
load to ensure if it is under
normal operation.
SW OCP
04
Output over current
Take all safety precaution, and
then check if the mains voltage
that is in specification. Turn on
the output power with a dummy
load to ensure if it is under
normal operation
SW OPP
06
Output over power
Take all safety precaution, and
then check if the mains voltage
that is in specification. Turn on
the output power with a dummy
load to ensure if it is under
normal operation.
Arc Number Limit
07
Arc number is over setting
parameter
Press and hold “OFF” button
with 10 second to clear error.
Contactor Interlock
10
Uninstallation of contactor pin in D-
sub connector
Check if contactor pin in D-sub
connector is short.
Output Interlock
11
Uninstallation of output cover
Check if output cover is
correctly installed.
Communication Loss
15
Error from internal communication
Check if the bus between panel
and control card is correctly
connected.
Fan1 Error
17
Error from the left fan
Check if the cable between fan
in the left module 1 and control
card is correctly connected.
Fan2 Error
18
Error from the right fan
Check if the cable between fan
in the right module 2 and control
card is correctly connected.
Bus UVP
20
Input voltage is under operation
range
Take all safety precaution, and
then check if the mains voltage
that is in specification.
Содержание HPH-20KA01KAT
Страница 1: ...User Manual DC Power Supply Continuous 400 1000 VDC Model HPH 20KA01KAT Version Rev S 00...
Страница 13: ...Delta Electronics Inc HPH 20KA01KAT 9...
Страница 15: ...Delta Electronics Inc HPH 20KA01KAT 11...
Страница 20: ...Delta Electronics Inc HPH 20KA01KAT 16 Energy Mode Monitor 06 While output reaches setting Energy A...
Страница 22: ...Delta Electronics Inc HPH 20KA01KAT 18...
Страница 29: ...Delta Electronics Inc HPH 20KA01KAT 25 6 3 Main Menu Map Fig 6 1 Panel tree...
Страница 41: ...Delta Electronics Inc HPH 20KA01KAT 37...