Delta Electronics. Inc.
HPH-
20KA01KAT
36
Parallel Fault IP14
114
Fault from PSU IP 14
Check the PSU with IP 14
independently to ensure the
operation is normal.
Parallel Fault IP15
115
Fault from PSU IP 15
Check the PSU with IP 15
independently to ensure the
operation is normal.
Parallel Fault IP16
116
Fault from PSU IP 16
Check the PSU with IP 16
independently to ensure the
operation is normal.
Parallel Fault Master
Communication Loss
223
Master fails to receive the ack from
slave while power on
Check the RJ46 cable is
correctly connected between
master and slave PSUs.
Parallel Fault Slave
Communication Loss
224
Slave fails to receive the ack from
Master while power on
Check the RJ46 cable is
correctly connected between
master and slave PSUs.
Warning Condition
Code
Description
Suggested Action
Arc Density Limit
01
Arc
density is over setting parameter N/A
Output Limit
02
Output is over setting parameter
N/A
Parallel Number
03
Parallel number is different between
setting and reality
Check if parallel number is
correct between setting and
system detection.
Parallel Mode
Communication Fault
04
Target Life
05
While output reaches setting Target
Life
Monitor setting is end. Re-turn
on the power. It will reset the
setting
Energy Mode Monitor
06
While output reaches setting Energy
Monitor setting is end. Re-turn
on the power. It will reset the
setting
Содержание HPH-20KA01KAT
Страница 1: ...User Manual DC Power Supply Continuous 400 1000 VDC Model HPH 20KA01KAT Version Rev S 00...
Страница 13: ...Delta Electronics Inc HPH 20KA01KAT 9...
Страница 15: ...Delta Electronics Inc HPH 20KA01KAT 11...
Страница 20: ...Delta Electronics Inc HPH 20KA01KAT 16 Energy Mode Monitor 06 While output reaches setting Energy A...
Страница 22: ...Delta Electronics Inc HPH 20KA01KAT 18...
Страница 29: ...Delta Electronics Inc HPH 20KA01KAT 25 6 3 Main Menu Map Fig 6 1 Panel tree...
Страница 41: ...Delta Electronics Inc HPH 20KA01KAT 37...