DC wiring polarities have two components, Plus and Minus, which are shown in
Figure 4-6.
The connection shall conform to the indication marked on inverter.
Table 4-2 : H4 connectors
Figure 4-6 : DC Wiring illustration
H4CMC2D-MS
H4CFC2D-MS
Specifications
2.5mm² / 14AWG
4mm² / 12AWG
6mm² / 10AWG
25A @85
˚
C
35A @85
˚
C
45A @85
˚
C
Description
contact size
rated current (TUV)
4.5.2 Battery connector
H5E_220 is currently compatible with the BX6.3_DD / BX12.6_DD battery system
as backup power.
BAT plugs and BAT cables
The battery plugs are provided along with the
package of battery system.
If you want to order more or need a different
size, see information in the following table.
a
b
Table 4-3 : H4 connectors
Specifications
2.5mm² / 14AWG
4mm² / 12AWG
6mm² / 10AWG
25A @85
˚
C
35A @85
˚
C
45A @85
˚
C
Description
contact size
rated current (TUV)
BAT wiring polarities have two components, Plus and Minus, which are shown in
Figure 4-7.
The connection shall conform to the indication marked on inverter.
Figure 4-7 : BAT Wiring illustration
H4PMC4TMS
H4PFC4TMS
19
Installation and Wiring
Содержание H5E 220
Страница 1: ...H5E_220 Operation and Installation Manual Grid tie Transformerless Hybrid Inverter www deltaww com...
Страница 2: ......
Страница 54: ......
Страница 55: ......
Страница 56: ...20220518...