5.6.6 Standalone mode
Operation mode select ‘Hybrid with backup charge - phase 2’, the system changes
to standalone mode automatically during a power outage occur. At this time, grid
side is disconnected and hybrid inverter operate in micro-grid to provide simulated
grid for home load and PV inverter. The detail configure application is described
in
Chapter 6
.
5.6.7 Forced charge mode
Forced charge mode is passive mode. Although battery stops any action when
SOC (State Of Charge) reach 0%, the self-discharge phenomenon may still
causing SOC lower than 0%.
At this time, hybrid inverter will force battery charging from PV power and grid
power until the battery SOC reaching SOC limit setting (default is 30%).
Solar Panel
DC
DC
Home Load
Main
Board
Feed-in / Purchase
Consumption
Charge / Standby
Grid
Light
TV
Refrigerator
Chargeing
CT
H5E_220
BX6.3_DD
BX6.3_EX
AC
19:00
12:00
07:00
00:00
24:00
PV power
PV power used
for home load consumption
Excess PV power
Home load power usage
37