Description
Default value
Operation mode
Select present operating serial port mode from the following options:
1. TCP
server:
as TCP server, create connection once receive client host request
then client host and DVW device can start data transmission.
2.
Close:
close transparent server function.
Close
TCP port
Set the port for TCP Server monitoring data packet.
12581
Baud rate
Set baud rates for serial ports. Optional values include 2400, 4800, 9600, 19200,
38400, 57600, 115200.
9600
Data bit
Set data bits for serial ports. Optional values include 7 or 8.
8
Parity bit
Set parity bits for serial ports. Optional values include “None”, “odd”or “even”.
None
Stop bit
Set stop bits for serial ports. Optional values include 1or 2.
1
Flow control
Set types of flow control. Optional values include “XON/XOFF”, “RTS/CTS”.
None