Chapter 4 Communication Protocol
Operating Manual for Communicating Area Sensor
4-3
times every two seconds)
5: Scan / diagnosis mode (constant light
in non-shading status, flashes once
per second in shading status)
activate upload
(Example 8)
008BH
W
Activate automatic upload
function
(Limited to measurement
operation mode)
0: Off
1: Activated and disable when restart
After every scan, the scan result will
auto-upload according to the setting
data content; scan time and content of
upload must be set before use; once
activated, product cannot receive any
commands.
After entering active upload
procedure, indicator will flash once
every two scans.
Note: After re-start, this function is in
OFF state.
2: Activated and keep when restart
After re-start, the product will scan and
diagnosis at first then active the
function. It will enter stop mode in this
re-start period when abnormal
happened. The function can be
disable in stop mode.
(after firmware V1030)
008CH
R/W
Setting automatic upload data
content
(Limited to measurement
operation mode)
0: The status of each beam Data length
= ((the number of beams-1)/8 + 1)
Every bit in the data represents the
corresponding beam.
1 represents shading
0 represents non-shading
1: Content is composed by the following
package: First shading beam; final
shading beam; total shading number;
and total shading length (cm)
008DH
R/W
Setting delay time 1 (0.1msec)
(Limited to automatic upload
application in measurement
operation mode)
After scanning and data upload, delay the
time of time1.
Maximum value is 255; can be used in
coordination with delay time 2.