Chapter 5 Troubleshooting and Others
Operating Manual for Communicating Area Sensor
5-3
2. non-shading/shading state can be inverter, active upload can be inverter
Invert light
beam state
0094H
R/W
Invert light beam state (Limited
to measurement operation
mode)
(Includes version v1031 and
later)
0060H ~ 006FH light beam state
Definition of light beam state 0 (default)
:
0060H ~ 006FH
bit = 1, mean no-shading
bit = 0, mean shading
1
:
0060H ~ 006FH
bit = 1, mean shading
bit = 0, mean non-shading
Inverter light
beam state in
activate upload
0095H
R/W
Inverter each light beam state
in activate upload, data state
definition(008CH=0)
(Limited to measurement
operation mode)
(Includes version v1031 and
later)
The definition of light beam state when
008CH=0
0 (default)
:
bit = 1, mean shading
bit = 0, mean non-shading
1
:
bit = 1, mean no-shading
bit = 0, mean shading
*Note
:
The definition is reverse with
0094H
3. When data change then upload active
activate upload
mechanism
0096H
R/W
The activate upload in 2
mechanism
(Limited to measurement
operation mode and activate
upload)
(Includes version v1031 and
later)
0 (default)
:
activate upload data
continuously
1: activate upload when any one light
beam status chage
4. Revert communication mode to default RTU 38400 8 N 1
After setting non-active upload, put the cable of Communication Receiver model Sync+ and FB+ together,
Sync- and FB- together. Power on the Receiver mode, can communicate by RTU 38400 8 N 1
5. Delete Modbus 7bits supporting.