1.2   Order Information                                                         

 

The Transmitter, Receiver, Wire and Bracket need to be ordered separately 

 

Transmitter/receiver model 

 
 
 
 
 
 
 
 
 

 

List of model 

AS-BF Series 

AS-BH Series 

AS-BA Series 

AS-BF016 

AS-BH008 

AS-BA004 

AS-BF024 

AS-BH012 

AS-BA006 

AS-BF032 

AS-BH016 

AS-BA008 

AS-BF040 

AS-BH020 

AS-BA010 

AS-BF048 

AS-BH024 

AS-BA012 

AS-BF056 

AS-BH028 

AS-BA014 

AS-BF064 

AS-BH032 

AS-BA016 

AS-BF072 

AS-BH036 

AS-BA018 

AS-BF080 

AS-BH040 

AS-BA020 

AS-BF088 

AS-BH044 

AS-BA022 

AS-BF096 

AS-BH048 

AS-BA024 

AS-BF104 

AS-BH052 

AS-BA026 

AS-BF112 

AS-BH056 

AS-BA028 

AS-BF120 

AS-BH060 

AS-BA030 

AS-BF128 

AS-BH064 

AS-BA032 

 

AS-BH068 

AS-BA034 

 

AS-BH072 

AS-BA036 

 

AS-BH076 

 

 

AS-BH080 

 

 

AS-BH084 

 

 

AS-BH088 

 

 

AS-BH092 

 

 

AS-BH096 

 

Area sensor 
B = Basic type 

AS - B  H  040 

Beam spacing 
F = 10mm 
H = 20mm 
A = 40mm 

-CX 

Number of 
beams 

Model 
-TX = transmitter model 
-RX = Receiver model    (Standard type) 
-CX = Receiver model (Communication type) 

Содержание AS-BA Series

Страница 1: ...et Installation 2 3 2 3 Description of Optical Detection Capability 2 5 Chapter 3 Installation and Operation 3 1 3 1 Wiring Instructions 3 1 3 2 Indicators 3 2 3 3 Installation 3 3 3 4 Operation Mode...

Страница 2: ...output that has 2 output NPN and PNP Object size detection CX model switching output and communication output Model AS BF series AS BH series AS BA series Minimal Detection Object 16 5mm 26 5mm 46 5mm...

Страница 3: ...48 AS BH024 AS BA012 AS BF056 AS BH028 AS BA014 AS BF064 AS BH032 AS BA016 AS BF072 AS BH036 AS BA018 AS BF080 AS BH040 AS BA020 AS BF088 AS BH044 AS BA022 AS BF096 AS BH048 AS BA024 AS BF104 AS BH052...

Страница 4: ...B WT100 AS B WR100 AS B WC100 Bracket information AS B BK01 AS B BK02 AS B BK03 AS B BK04 A Bracket package include 2pcs The bracket installation depend on the detection height the number of bracket...

Страница 5: ...mechanisms Reverse voltage protection output over current protection input surge protection output surge protection Operating temperature 10 C 55 C No freezing Storage temperature 25 C 60 C No freezin...

Страница 6: ...municating Area Sensor 2 2 Product exterior and dimensions Unit mm Positions of beams and indicators unit mm Operation indicator Final beam First beam Alignment indicator Alignment indicator Beam spac...

Страница 7: ...Chapter 2 Product Specifications Operating Manual for Communicating Area Sensor 2 3 2 2 Bracket Installation Bracket dimension and installation AS B BK01 dimensions unit mm AS B BK02 AS B BK03...

Страница 8: ...Chapter 2 Product Specifications Operating Manual for Communicating Area Sensor 2 4 AS B BK04...

Страница 9: ...r of lenses transmitting and receiving beams Detection height The distance between the highest point and the lowest point within the limit of object detection capability Detecting distance The distanc...

Страница 10: ...AS BA014 520 568 6 AS BF064 630 648 6 AS BH032 620 648 6 AS BA016 600 648 6 AS BF072 710 728 6 AS BH036 700 728 6 AS BA018 680 728 6 AS BF080 790 808 6 AS BH040 780 808 6 AS BA020 760 808 6 AS BF088...

Страница 11: ...2 4 4 13 2 AS BF056 14 0 42 AS BH028 8 0 24 AS BA014 4 8 14 4 AS BF064 16 2 48 6 AS BH032 8 8 26 4 AS BA016 5 2 15 6 AS BF072 18 0 54 AS BH036 9 8 29 4 AS BA018 5 8 17 4 AS BF080 20 0 60 AS BH040 10 8...

Страница 12: ...F064 55 70 70 AS BH032 40 45 45 AS BA016 45 45 45 AS BF072 60 80 80 AS BH036 45 50 50 AS BA018 50 50 50 AS BF080 65 85 85 AS BH040 50 55 55 AS BA020 50 50 50 AS BF088 70 90 90 AS BH044 50 60 60 AS BA0...

Страница 13: ...ransmitter FB FB Feedback signal from the transmitter RX_NPN NPN output RX_PNP PNP output CX_RS485 RS485 MODBUS ASCII RTU CX_Output Can be set to NPN PNP or Push Pull via communication setting Shieldi...

Страница 14: ...Operation Operating Manual for Communicating Area Sensor 3 2 3 2 Indicators Description of positions of indicators Alignment indicator blue Alignment indicator blue First beam Operation indicator gree...

Страница 15: ...icators blue on both sides are lit at the same time 3 Rotate area sensor to change the operation indicator from red to green Installation instructions not affected by the mirror Safe installation dist...

Страница 16: ...interference from adjacent light sources Staggered left right installation to avoid interference from adjacent light sources Staggered up down installation to avoid interference from adjacent light s...

Страница 17: ...nstallation and Operation Operating Manual for Communicating Area Sensor 3 5 Staggered front rear installation to avoid interference from adjacent light sources Transmitter 1 Receiver 1 Receiver 2 Tra...

Страница 18: ...any light beam and the output is ON Green Light when it is non shading In the OFF state sensor do FB diagnosis voltage diagnosis and light beam diagnosis cyclically Output to ON state when all the di...

Страница 19: ...aution When switching operation mode please remove OUTPUT from the host for preventing malfunction Description of indicator display and output status Operation mode Status description Output status Al...

Страница 20: ...Description of output mode Shading over current OFF O V V second Abnormal number of beams OFF V V Fixed Feedback Voltage abnormal and switch to Stop mode OFF V Mode1 ON OFF Mode 2 measurement mode Fu...

Страница 21: ...ill be detected when it exceeds the detection height The default setting is full beam enabled Floating mask function It is applied to the detection of obstacles in an unfixed position such as detectin...

Страница 22: ...light indicator when object is blocked red light will still be lit Work area Activating interlock mechanism Green light ON Interlock mechanism activated Object passing through Red light OFF Object en...

Страница 23: ...to avoid danger it must be actually tested to see if it meets requirement before the product output can be connected to the host Function Position Read write Name Description of numerical value Basic...

Страница 24: ...F operation mode 0 Off Default 1 Activated Takes effect immediately after setting 0087H W Restart interlock function Limited to ON OFF operation mode can only be carried out when green light is on 1 R...

Страница 25: ...F state 2 Activated and keep when restart After re start the product will scan and diagnosis at first then active the function It will enter stop mode in this re start period when abnormal happened Th...

Страница 26: ...cutive ON must exceed the number of this setting then the result will output ON Unit is the cycle of one scan time Default value is 0 which means this function is turned off Maximum value is 255 0093H...

Страница 27: ...no shading beams 2 Enable the interval beams between start beam 0099H and end beam 009AH include start beam and end beam 3 Enable the out of interval beams between start beam 0099H and end beam 009AH...

Страница 28: ...multaneously with fixed blanking 00A4H R The last hole Limited to mode 2 and 5 Includes version v1021 and later Cannot be used simultaneously with fixed blanking 00A5H R The last shading Limited to mo...

Страница 29: ...e used simultaneously with fixed blanking 00AEH R The sixth last hole Limited to mode 2 and 5 Includes version v1021 and later Cannot be used simultaneously with fixed blanking Fixed blanking Example...

Страница 30: ...ms 40 33 0045H corresponds to beams 48 41 0046H corresponds to beams 56 49 0047H corresponds to beams 64 57 0048H corresponds to beams 72 65 0049H corresponds to beams 80 73 004AH corresponds to beams...

Страница 31: ...light status of RX beam Limited to ON OFF measurement and scan diagnosis operation mode High Byte represents mode 1 ON OFF mode 2 Measurement mode 5 Scan diagnosis mode Low Byte from high to low bit...

Страница 32: ...ASCII RTU Set floating blanking number to 3 01060085000371 01 6 00 85 00 03 D8 22 Example 3 Fixed blanking function Limited to ON OFF and measurement operation mode Note Takes effect immediately afte...

Страница 33: ...etting Default 0 represents NPN 1 represents PNP 2 represents Push Pull Executed action ASCII RTU Set to PNP 0106008900016F 01 06 00 89 00 01 99 E0 Example 6 Operation mode Note Before mode switching...

Страница 34: ...esponse 010308023F020002C0 021FCE 01 03 08 02 3F 02 00 02 C0 02 1F 9B C3 Numerical value response is as shown below Where high byte 02H represents measurement mode low byte represents beam state Note...

Страница 35: ...RTU Non shading shading state of each beam 0106008C00006D 01 06 00 8C 00 00 48 21 3 Set scan cycle to scan time Note 1 data upload time Note 2 delay time setting default value is 0 Executed action ex...

Страница 36: ...depend on the number of beams The state of every beam is expressed by 1 bit 1 represents shading 0 represents non shading Take RTU as an example Data ID 1 2 3 4 5 N 3 N 4 N 5 Item Device address Func...

Страница 37: ...20mm and two objects shaded in the middle The returned data is as shown below Channel 1 8 9 16 17 24 25 32 008CH 0 Data 1 Data 2 Data 3 Data 4 Data Hex 03 F0 3C 00 Beam state bit 0 0 0 0 0 0 1 1 1 1 1...

Страница 38: ...80 55 00A2H The number from the first shading beam to the final one 80 55 00A3H Total length from the first shading beam to the final one 160 110 00A4H The last hole 0 25 00A5H The last shading 8 29...

Страница 39: ...7 6 AS BH028 C 4 5 AS BA014 C 2 9 AS BF064 C 8 7 AS BH032 C 5 0 AS BA016 C 3 2 AS BF072 C 9 6 AS BH036 C 5 5 AS BA018 C 3 4 AS BF080 C 10 5 AS BH040 C 5 9 AS BA020 C 3 6 AS BF088 C 11 4 AS BH044 C 6...

Страница 40: ...17 AS BA012 C 7 15 AS BF056 C 12 25 AS BH028 C 9 19 AS BA014 C 7 15 AS BF064 C 13 27 AS BH032 C 9 19 AS BA016 C 7 15 AS BF072 C 14 29 AS BH036 C 10 21 AS BA018 C 8 17 AS BF080 C 15 31 AS BH040 C 10 2...

Страница 41: ...286 5 572 9 763 9 1145 8 8 N 2 4 191 0 286 5 572 9 763 9 1145 8 8 O 2 5 208 3 312 5 625 0 833 3 1250 0 8 E 2 6 208 3 312 5 625 0 833 3 1250 0 7 O 1 7 173 6 260 4 520 8 694 4 1041 7 7 E 1 8 173 6 260 4...

Страница 42: ...er machine shutdown been improved Light source interference Is there any external glare affecting device Installation of multiple light curtains should use transmitter receiver staggered format Blue g...

Страница 43: ...can cancel Activate upload function It works when power on Transmitter and Receiver models simultaneously V1 03 10 software version update 1 Rapid Light Beams Enable 4modes for ALL ON NOW IN OUT Rapid...

Страница 44: ...measurement operation mode Includes version v1031 and later The definition of light beam state when 008CH 0 0 default bit 1 mean shading bit 0 mean non shading 1 bit 1 mean no shading bit 0 mean shad...

Страница 45: ...8882 0603 Wuhan Telephone 027 8544 8265 Fax 027 8544 9500 Changsha Telephone 0731 8827 7881 Fax 0731 8827 7882 Nanning Telephone 0771 5879 599 Fax 0771 2621 502 Xiamen Telephone 0592 5313 601 Fax 059...

Страница 46: ...must be evaluated Safety light curtain must be used for the following machinery equipment specified by the competent authority 1 Power punching shearing machine 2 Hand feed planer 3 Circular saw for...