background image

063222A / 063222SS / 063222BL

Proximity Gooseneck Spout Assembly

0.5 GPM (1.9 L/min)

063226A / 063226SS / 063226BL

Proximity Gooseneck Spout Assembly

1.0 GPM (3.8 L/min)

063227A / 063227SS / 063227BL

Proximity Gooseneck Spout Assembly

1.5 GPM (5.7 L/min)

063229A / 063229SS / 063229BL

Proximity Gooseneck Spout Assembly

2.2 GPM (8.3 L/min)

RP6087

Nut & Washer

061206A

Proximity

Sensor Module

Page 1

209989   Rev. B

62__TP3__ __ __

Write  purchase model number here for future reference

PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as

items relating to ongoing maintenance suggestions and procedures are included.

060683A

24VAC to 6VDC Converter

061259A

Ground Wire Kit

(for hardwire models)

061047A

24VAC to 6VDC Converter with

Battery Backup

061256A

36” Sensor Module Extension Cable

061266A

Laminar Outlet (3/pkg, 1 key)

0.5 GPM (1.9 L/min)

061267A 

Laminar Outlet (3/pkg, 1 key)

1.0 GPM (3.8 L/min)

061268A

Laminar Outlet (3/pkg, 1 key)

1.5 GPM (5.7 L/min)

061296A

Laminar Outlet (3/pkg, 1 key)

2.2 GPM (8.3 L/min)

209989

   

     

  209989

   

   

   

 209989

   

   

   

 209989

209989

    

    

  209989

    

    

  209989

   

     

  209989

w w w . s p e c s e l e c t . c o m

 

OPTION LIST

 

TRANSFORMERS

060704A

Transformer 110 to 24 VAC 20VA

up to 5 Electronic Valves

060771A

Transformer 110 to 24 VAC 40VA

up to 10 Electronic Valves

DECK PLATES

061269A / 061269SS / 061269BL

4” Deck Plate & Hold-Down Pkg

061270A / 061270SS

8” Deck Plate & Hold-Down Pkg

 

 

061295A

Nut & Washer

061269A

061269SS

061269BL

4” Deck Plate

& Holddown Pkg

061270A

061270SS

8” Deck Plate

& Holddown Pkg

061294A

Single Hole

Deck Gasket

for Proximity

Gooseneck

(6/pkg)

061293A

Spacer package for

Proximity Gooseneck

060681A

Battery Holder

Model Number

621TPxxx0

621TPxxx1TR

621TPxxx8TR

620TPxxx0

620TPxxx1TR

620TPxxx8TR

Description

Battery Operated Surface Mount Box #0

Battery Operated Control Box #1 Trim

Battery Operated Control Box #8 Trim

Hard Wire Operated Surface Mount Box #0

Hard Wire Operated Control Box #1 Trim

Hard Wire Operated Control Box #8 Trim

Page #

2

4

6

8

10

12

COVER

060073A

Screws (4/pkg) and driver bit for covers

060577A

12” Stainless Steel Cover

TMV Repair Kits

061137A

Adjustment Wrench

063164A

Check Valves (2/pkg)

INSTALLATION AND SET-UP INSTRUCTIONS

063128A

Battery Box Assembly less driver

board and battery holder

060905A

Cover Gasket

060906A

Surface

Mount Housing

061252A

Dual

Driver Board

060909A

Screen Assembly

063131A

3/8” Comp Connect Nut & Ferrile

063127A

Solenoid Valve with 3/8”

Compression Connectors

and Solenoid Holder

062032A

Braided Polymer Hose

060908A

Solenoid Holder

062032A

Braided Polymer Hose

 

NOTES:

For optimum performance of this product, the recommended

system pressure is between 20 and 80 PSI static.  This 

product will operate up to a maximum of 125 PSI static

per ANSI and CSA requirements.  However, it is not 

recommended the pressure go above 80 PSI.  Thermal

expansion or leaking pressure reducing valves may require

the use of expansion tanks or relief valves to ensure your

system never exceeds its maximum intended pressure 

setting.

Control Box #0 and #1

Designed for routine 180°F (82°C) disinfection cycles up to

10 minutes.

Control Box #8

High temperature disinfection cycles not recommended

for #8 control box as the thermostatic mixing valve limits

the higher temperature water flow output.

• Use 3-conductor 18AWG wire between transformer and

  hardwire converter / driver board earth ground.

• Use Delta Commercial approved transformers and mount

  the transformer a minimum of 6” (152 mm) away from the

  Delta driver board enclosure.

• Refer to 

Proximity Application Notes

 on SpecSelect for

  installation best practices, proper grounding and wiring

  diagrams.

Содержание 62 TP3 Series

Страница 1: ...xx8TR Description Battery Operated Surface Mount Box 0 Battery Operated Control Box 1 Trim Battery Operated Control Box 8 Trim Hard Wire Operated Surface Mount Box 0 Hard Wire Operated Control Box 1 Trim Hard Wire Operated Control Box 8 Trim Page 2 4 6 8 10 12 COVER 060073A Screws 4 pkg and driver bit for covers 060577A 12 Stainless Steel Cover TMV Repair Kits 061137A Adjustment Wrench 063164A Che...

Страница 2: ... in accordance with local plumbing and electrical codes FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION Fig 3 w w w s p e c s e l e c t c o m 621TPxxx0 Battery Operated Surface Mount Box 0 Mount faucet to sink using the provided components in the following order grey bottom spacer washer lock nut Fig 1 NOTE The black top spacer must be used at all times between the spout and countertop sink and the...

Страница 3: ...tance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ensuring a smooth...

Страница 4: ... at the box outlet Connect water supply through to spout Assure supply lines are completely flushed and free of debris Install aerator Product supplied as shown by solid lines All items shown by dotted lines supplied by others Typical Installation Recessed Mount Box Flexible Sensor Cord Conduit Polymer Braided Hose 257mm 10 13 Control Box 305mm 12 Stainless Steel Cover Plate 102mm 4 355mm 14 max F...

Страница 5: ...round a conductor the spout and monitoring the change in capacitance that the conductor undergoes The change in capaci tance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the ...

Страница 6: ... spacer is for temporary use only for flushing of system Must be replaced with solenoid and washers Figure 13 STEP 4 FLUSH SYSTEM SET TEMPERATURE Remove coverplate from control box Open screwdriver stop s to flush installation for one minute minimum 4A Run water for a sufficient time so the hot and cold water supplies are as hot and cold as possible 4B Place a thermometer in a plastic container an...

Страница 7: ...tion is complete and the faucet is ready to use The cover should be secured at this time STEP 6 TEST FOR OPERATION Test for operation If OK then close lid Use caution not to damage wires or components on electronic driver board Route wires through notches openings in the box See Fig 18 Secure lid using screws If faucet leaks from spout outlet SHUT OFF WATER SUPPLIES Check proper solenoid connectio...

Страница 8: ...e converter Refer to Fig 24 and Fig 25 for reference wiring diagrams Install the grounding kit assembly 061259A per the supplied instruction sheet for proper grounding with Conductive and Non Conductive sinks Turn on power supply for the transformer 5 quick beeps 3 times will be generated when power is first applied to the unit At this stage step back at least 3 feet from the controller and spout ...

Страница 9: ... change in capacitance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ...

Страница 10: ...f system Must be replaced with solenoid and washers Figure 28 STEP 3 CONNECT WATER SUPPLY Install sink and connect drainage to rough in See Figure 28 Polymer braided hose supplied must be connected to the spout Other connection tubes and fittings are supplied by the installer to connect to the 1 2 nominal sweat at the box outlet Connect water supply through to spout Assure supply lines are complet...

Страница 11: ...s The solenoid will stay open while hands are moving then close once hands are removed from the sensing zone CONDUCTIVE SINKS NON CONDUCTIVE SINKS Fig 33 Fig 32 Metal Sink Mounting Hardware or Bracket Control Box 1 Driver Board P3 GND 120VAC Ground Electrical Box Metal Box Ground Wiring Sink Ground Wiring Earth Ground Wiring Control Box 8 To Additional Sinks Driver Boards Vitreous China Sink Contr...

Страница 12: ...cer is for temporary use only for flushing of system Must be replaced with solenoid and washers Figure 35 STEP 4 FLUSH SYSTEM SET TEMPERATURE Remove coverplate from control box Open screwdriver stop s to flush installation for one minute minimum 4A Run water for a sufficient time so the hot and cold water supplies are as hot and cold as possible 4B Place a thermometer in a plastic container and ho...

Страница 13: ...LIBRATION After power is applied to the driver board it generates 5 quick beeps 3 times which prompts the installer to step away from the unit During the calibration process the water will turn ON for several seconds then proceed to shut off An additional 5 beeps indicates calibration is complete and the faucet is ready to use The cover should be secured at this time STEP 6 TEST FOR OPERATION Test...

Страница 14: ...to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ensuring a smooth signal is carried...

Страница 15: ...seconds 2 0 2 5 3 0 minutes Metering Mode b Buzzer For Proximity the buzzer setting does not silence the controller and sensor status annunciations Buzzer options are ON and OFF the default setting is ON ON ON OFF M This feature changes the product into a metering faucet it will run the full set amount of time after the user s hands are first detected Note Auto Timer T is disabled when the feature...

Страница 16: ...nd water closets HARSH ABRASIVES or POLISH To clean simply wipe the surface with a damp cloth and blot dry with a soft cloth CARE INSTRUCTIONS Proximity sensing technology works by sensing changes in the electrical field Nearby conductive materials that are electrically charged or not properly electrically grounded may interfere with the desired function of the product If the controller is unable ...

Страница 17: ...oid are functioning Ensure inlet screen on solenoid is not plugged with debris Check the incoming water supply Turned on proper pressure and volume etc Check for a pressure lock between the mixing valve and the solenoid Turn off the water supply and undo the connection to the inlet of the solenoid this will eliminate any built up pressure Then activate sensor and test fire the solenoid If after ab...

Страница 18: ...is warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta Faucet Canada a division of Masco Canada Limited and is void for any damage to this faucet due to misuse abuse neglect accident improper installation any use in violation of instructions furnished by Delta Fa...

Отзывы: