If Hardwire Operated

• 

Attach hardwire converter supplied to the 24VAC power source using the wire 

nuts provided.

• 

Attach converter to the sensor module using the snap connector. With power 

to flushometer, there will be a sequence of red lights that strobe across the 

sensing lens window which signifies that the valve is now in operation mode.

• 

4” Plate Models - Connect the female connectors from the sensor module to the solenoid flush valve. A 1,220 mm (48“) solenoid 

extension cord has been provided, if required, to make the connection between the sensor module and solenoid. Make sure to correctly 

match the wire colours on the sensor module to the solenoid. 

• 

14” Plate Models - Connect the female connectors from the sensor module to the solenoid on the flush valve. Make sure to correctly 

match the wire colours on the sensor module to the solenoid.

• 

If the factory default settings for the sensor are not suitable, refer to step 4 for sensor adjustments.

• 

Attach sensor plate to the box using the 4 vandalproof screws provided.

If Battery O

perated

• 

Install 4 “C” cell batteries provided into the battery holder and attach the holder to the sensor module using the battery clip. Use the +/- 

on the battery holder for correct battery positioning. With power to flushometer, there will be a sequence of red lights that strobe across 

the sensing lens window which signifies that the valve is now in operation mode.

• 

4” Plate Models - Connect the female connectors from the sensor module to the solenoid flush valve. A 1,220 mm (48“) solenoid 

extension cord has been provided, if required, to make the connection between the sensor module and solenoid. Make sure to correctly 

match the wire colours on the sensor module to the solenoid.

• 

4” Plate Models - Install battery holder into the back of the box and attach the sensor plate to the box using the 4 vandalproof screw 

provided. 

• 

14” Plate Models - Connect the female connectors from the sensor module to the solenoid on the flush valve. Make sure to correctly  

match the wire colours on the sensor module to the solenoid. 

• 

If the factory default settings for the sensor are not suitable, refer to step 4 for sensor adjustments.

• 

14” Plate Models - Attach battery holder with the 2 way tape provided, to a secure location on the wall framing, etc.

STEP 2 - INSTALL SENSOR PLATE

Sensor Extension Cord

Fig. 2

STEP 3 - OPERATION MODE

A sequence of red lights that strobe across the sensing lens window will signify that the valve is now in operation mode.

Once in operation mode, if factory settings are preferred, no further action is required and the valve installation is complete.

 

Factory pre-set functions are:

Water closet sensing distance of 40” and flush delay is 4 seconds.

Urinal sensing distance of 20”, 24 hour flush is off, and no flush delay.

Once in operation mode, if adjustments are preferred, installer must move into set up mode.

FUNCTION AND TROUBLESHOOTING LIGHTS

BATTERY VERSION: NO LIGHTS-NO POWER

Check that the 4 “C” batteries are positioned properly in the battery holder. Use the +/- on the battery holder for correct positioning. If the 

batteries are positioned correctly but there are still no lights, replace with 4 new “C” Alkaline batteries.*

HARDWIRE VERSION: NO LIGHTS-NO POWER

Check that the 24VAC transformer has power on the incoming 120VAC side. (Transformer breaker is turned on.) 

Check the connection of the flushometer wires to 24VAC transformer. 

Check that the connection of the hardwire converter is made to the electronic board within the electronic flush valve housing.

For further technical assistance, call Delta Commercial Technical Service at 1-800-387-8277 (Canada) or 1-877-509-2680 (U.S.A.).

1.  Start-Up:

 When the system is first powered, a sequence of red lights that strobe across the sensing lens window will signify that the 

valve is now in operation mode.

2.  Override Button in Operating Mode: 

BLUE light flashes once when Override Button is activated. Should the manual override button 

stick, the program will continue to operate and will reset automatically if the override button is repaired or it returns to home position.

3.  Battery Level Indicator: 

RED light flashes every 3 seconds, indicating approximately 5,000 flushes remain from when RED light first 

started flashing.

4.  Checking Battery Strength:

 In operation mode, it is possible to check the strength of the batteries by holding down the override 

button until the RED lights begin to flash. The strength of the batteries is proportional to the number of lights that are displayed when 

the override button is held down. For example, 5 RED lights signify full battery strength; while 1 RED light indicates very weak battery 

strength (replace batteries when this occurs).

 * 

Note: 

All original settings will be retained when batteries are changed.

Содержание 160 T6 Series

Страница 1: ...d 213777 Rev A Electronic Concealed Flushvalve 160__T6__ __ __A series Write purchase model number here for future reference 6 13 14 24VAC 6 VDC Filter Screen Nut Fibre washer Rubber washer Slip Joint Nut Installation For valves manufactured after October 2014 11b 8b 11a 11c 9 8a 12 15 22 10b 10a 10c 3 2 22 23 16 5 18 17 6 19 20 4 26 7 21 25 1 24 ...

Страница 2: ...6 gal adjustable water closets see Table 1 9 060078A Screws for Cast Cap 4 pkg 10a 061323A Diaphragm Guide Assembly Complete W C see Table 1 10b 061324A Diaphragm Guide Assembly for Urinals See Table 1 10c 060079A MMO Diaphragm only 12 pkg 11a 060507A Poppet Pin Pack 3 pkg also see 11b See Table 1 11b 060508A Poppet Pin Pack 3 pkg 0 5L Valves only See Table 1 11c 062025A Washer 3 pkg required for ...

Страница 3: ...061341A 060508A 061324A 1 9L 0 5 gal 061342A 060507A UR Adjustable 1 9L 0 5 gal 061346A W C Fixed 4 2L 1 1 gal 061343A 060507A 062025A 061323A 4 8L 1 27 gal 061344A 6 0L 1 6 gal 061345A W C Adjustable 6 0L 1 6 gal 061169A NOTE Must use all noted components listed in Table 1 to ensure correct flush volumes Fixed models have epoxy in the adjustment screw WaterSense compliant when paired with a WaterS...

Страница 4: ...M VALVES The FIRST FLUSH should ELIMINATE all air from the TECK flushometer DO NOT ADJUST flushometer based on the results of the first flush TO PREVENT WATER HAMMER A capped pipe vertical AIR CHAMBER may be installed at the last flushometer and or at the back of an individual installation This assures SMOOTHER OPERATION of the valves and longer life for the working parts FLUSH VOLUME ADJUSTMENT 1...

Страница 5: ... are positioned correctly 4 Sensor Plate Models If Battery Operated 102 mm 4 box and 4 box extension is supplied Remove suitable knockout as per Fig 1A Attach box extension to front of the box Rough in box assembly for sensor location as per Fig 1D Note Solenoid extension cord supplied with the trim is 1 220 mm 48 long Securely attach box to wall structure Attach supplied plasterguard as per Fig 1...

Страница 6: ... Solid Lines All Items Shown by Dotted Lines Supplied by Others 76mm 3 to BOF 76mm 3 to BOF of sensor Centerline C L of sensor Centerline C L of sensor Centerline C L 165mm 6 5 222mm 8 75 to BOF of sensor of sensor of sensor 57mm 2 25 to BOF 4 1 2 square stainless steel plate box 4 x 4 14 square stainless steel plate frame 12 x 12 14 x 20 stainless steel plate frame 12 x 18 4 1 2 square stainless ...

Страница 7: ... the wall framing etc STEP 2 INSTALL SENSOR PLATE Sensor Extension Cord Fig 2 STEP 3 OPERATION MODE A sequence of red lights that strobe across the sensing lens window will signify that the valve is now in operation mode Once in operation mode if factory settings are preferred no further action is required and the valve installation is complete Factory pre set functions are Water closet sensing di...

Страница 8: ...ng distance for urinal 24 sensing distance for water closet Press override button until pulsating blue light is present The blue light indicates that the sensing distance has been adjusted to a position that is detecting you Water closet only Now stand back and ensure that the pulsating blue light disappears when you stand near the door of the water closet Ensure that the door is not being detecte...

Страница 9: ...e size calculations be done to insure proper water supply sizes Flushometers DO NOT provide a water supply they are merely automatically timed self closing valves The inlet supply piping is the water reservoir that must supply sufficient water volume in a short period of time 4 to 10 seconds to properly flush and clear the fixture CONTINUOUS FLUSHING 1 The Regulating Screw 061024A item 8a may be t...

Страница 10: ...ERIOD OR THE DURATION OF THIS WARRANTY WHICHEVER IS SHORTER Some states provinces do not allow limitations on how long an implied warranty or condition lasts so the above limitation may not apply to you Limitation of Special Incidental or Consequential Damages MASCO CANADA LIMITED SHALL NOT BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING LABOR CHARGES TO REPAIR REPLACE INST...

Отзывы: