Turbo PMAC Clipper Hardware Reference Manual
Drive – Motor Setup
59
// Channels 9-12 PID Gains (with default clock settings):
I930,4,100 = 11190
; Motors 9-12 Proportional Gain
(Second Acc-1P)
I931,4,100 = 0
; Motors 9-12 Derivative Gain
(Second Acc-1P)
I932,4,100 = 15038
; Motors 9-12 Velocity FeedForward Gain
(Second Acc-1P)
I933,4,100 = 0
; Motors 9-12 Integral Gain
(Second Acc-1P)
I934,4,100 = 0
; Motors 9-12 Integral Mode
(Second Acc-1P)
I935,4,100 = 0
; Motors 9-12 Acceleration FeedForward Gain
(Second Acc-1P)
Note
At this point of the setup, the drive-motor(s) is ready to accept Jog
commands.