The following table reports the indications provided by the instrument as they appear on the display, 
together with their description. 
 

Display indications

 

Explanation

 

 

 

>>>_LOG_DUMP_or_ERAS 

 

transfer or erase data

 

BATT TOO LOW - CHNG NOW 

 

battery discharged - replace it immediately

 

BAUDRATE >>> 

 baud rate value 

COMM STOP 

 printing complete 

COMM STRT 

 printing started 

DAY_ 

day 

DUMP_END 

 data transfer complete 

DUMP_In_PROG >>> 

 data transfer in progress 

ERR 

 error 

FUNC CLR 

 max, min and average values clearing 

FUNC CLRD 

 max, min and average values cleared 

HOUR 

 hour 

INTG LIMT fcdS >>>> 

 integration limit in fcd 

INTG LIMT J/m2 >>>> 

 integration limit in J/m2 

INTG LIMT luxS >>>> 

 integration limit in lux 

INTG LIMT uJ/cm2 >>>> 

 integration limit in (J/cm2 

INTG LIMT umolm2 >>>> 

 integration limit in (mol/m2 

LOG In PROG 

 logging in progress 

LOG MEM FULL 

 

memory full 

LOG_CLRD 

 memory data cleared 

LOG_STOP 

 logging complete 

LOG_STRT 

 

logging started

 

MIN  >>> USE_UNIT_TO_ZERO SEC 

 

minutes >>> use the UNIT key to reset the seconds

 

MNTH 

 

month

 

NEW_PROB_DET 

 

new probe detected

 

NO_PRBE_ SER_NUM 

 

the connected probe's serial number is absent

 

OVER 

 

maximum limit exceeded

 

PLS_EXIT >>> FUNC RES_FOR_FACT 
ONLY 

please exit using ESC >>> function reserved to factory calibration

 

PRNT AND LOG INTV 

 

printing and logging intervals

 

PRNT INTV >>> 

 

printing interval

 

 

PROB COMM LOST 

 

lost communication with probe

 

PROB ERR 

 

error - unexpected probe

 

PRBE_SER #### #### 

 

serial number #### #### of the connected probe

 

SLP_MODE_LOG 

 

turning off during recording mode

 

SYS ERR # 

 

program error number #

 

TIME LIMT HOUR 

 

integration time limit in hours

 

TIME LIMT MIN 

 integration time limit in minutes

 

TIME LIMT SEC 

 integration time limit in seconds

 

YEAR 

 

year

 

 

-      - 

16

Содержание HD2102.1

Страница 1: ...This situation can cause possible differences comparing this manual with the instrument you bought We regret in advance for any possible mistake in this manual Data drawings and descriptions included...

Страница 2: ...Photo Radiometer HD2102 1 2...

Страница 3: ...en the key is pressed in the menu decreases the current value 9 SERIAL key starts and ends data transfer to the serial communication port 10 MENU CLR Q t key allows access to and exit from the menu If...

Страница 4: ...Photo Radiometer HD2102 2 4...

Страница 5: ...ey during normal operation starts and ends the saving of the measured or integrated data Q T in the internal memory in the menu starts the data transfer from the instrument s memory to the PC 11 MENU...

Страница 6: ...n the menu When exceeded these thresholds cause the instrument to stop the integral calculation The HD2102 2 instrument is a datalogger It memorizes up to 38 000 samples which can be transferred from...

Страница 7: ...detection of the probe connected to the input and sets the instrument ready for normal measurement MIN cm min s 2 3 m m k If during turning on no probes are connected the message PROB ERR is displaye...

Страница 8: ...ction cannot be transferred to the PC HOLD key It increases the current parameter when used in the menu when used in measurement mode it freezes the measurement in progress and upon application of pre...

Страница 9: ...previously been set for the calculation by pressing the FUNC ENTER and UNIT Q T keys When used in the menu it clears or cancels the active function REL key In measurement mode it displays the differe...

Страница 10: ...e moment of sampling and will turn off immediately afterwards thus increasing the battery life Using the arrows select YES and confirm using ENTER in order to enable the automatic turning off select N...

Страница 11: ...d subsequent stop represent a block When the logging function is on the LOG indication is on the display the battery symbol blinks and a beep is issued each time a logging occurs when using an externa...

Страница 12: ...ing on the display upon pressing the SERIAL key is printed the variable associated with the probe connected to the instrument with its relevant unit of measurement or the integral Q t Before starting...

Страница 13: ...nu When exceeded these thresholds cause the instrument to stop the integral calculation The probe is detected during turn on and this cannot be performed when the instrument is already on therefore if...

Страница 14: ...ressing Start Stop Q t in this status to resume the integration press the key again If one or more limits have been enabled in the menu on reaching of the first the calculation stops Pressing FUNC ENT...

Страница 15: ...following table lists all error indications and information displayed by the instrument and supplied to the user in different operating situations Display indications Explanation ERR This appears if t...

Страница 16: ...LIMT umolm2 integration limit in mol m2 LOG In PROG logging in progress LOG MEM FULL memory full LOG_CLRD memory data cleared LOG_STOP logging complete LOG_STRT logging started MIN USE_UNIT_TO_ZERO S...

Страница 17: ...the batteries in order to turn the instrument back on In order to avoid data loss the logging session is ended if the HD2102 2 is logging and battery voltage falls below the minimum operating level T...

Страница 18: ...Always use good quality leakproof alkaline batteries Sometimes on the market it is possible to find new batteries with an insufficient charge capacity INSTRUMENT STORAGE Instrument storage conditions...

Страница 19: ...USB 2 0 connection does not require the setting of parameters The instruments are provided with a complete set of commands and data queries to be sent via the PC All the commands transferred to the i...

Страница 20: ...5 10 3600 seconds WC0 Setting SELF off WC1 Setting SELF on Command characters are exclusively upper case characters Once a correct command is entered the instrument responds with when any wrong combi...

Страница 21: ...mand press the MENU key until the _LOG_DUMP_or_ERAS item is displayed and then press on LOG key During data transfer the display shows the message DUMP to stop the data transfer press ESC on the instr...

Страница 22: ...g SERIAL again NOTES The print out is formatted across 24 columns Some keys are disabled during serial transmission The following keys work ON OFF HOLD FUNC Max Min Avg and LOG Pressing the HOLD REL a...

Страница 23: ...The parameter remains in the memory until replacement of the batteries 4 Launch the DeltaLog9 application and press CONNECT Wait for the connection to occur and follow the indications on the screen F...

Страница 24: ...mplete the device will be detected on each new connection automatically In order to check if the entire operation was successful in CONTROL PANEL double click on SYSTEM Select Device Manager and conne...

Страница 25: ...ed with instrument off 20 A Mains Output mains adapter 9Vdc 250mA Measuring units lux fcd lux s fcd s W m2 W cm2 J m2 J cm2 mol m2 s mol m2 cd m2 Security of memorized data Unlimited independently of...

Страница 26: ...onnector Mains adapter 2 pole connector positive at centre EMC standard regulations Security EN61000 4 2 EN61010 1 level 3 Electrostatic discharge EN61000 4 2 level 3 Electric fast transients EN61000...

Страница 27: ...f6 T Temp coefficient 0 05 K Drift after 1 year 1 Working temperature 0 50 C Reference standard CIE no 69 LUMINANCE measurement probe LP 471 LUM 2 complete with SICRAM module and equipped with the in...

Страница 28: ...9 99 200 0 1999 9 2000 10000 Resolution mol m2 s 0 01 0 1 1 Spectral range 400nm 700nm Calibration uncertainty 5 f 1 response according to the cosine law 6 f3 linearity 1 f4 instrument reading error 1...

Страница 29: ...9 Resolution W m2 0 1 10 3 0 001 0 01 0 1 Spectral range 400nm 1050nm Calibration uncertainty 5 f 1 response according to the cosine law 6 f3 linearity 1 f4 instrument reading error 1digit f5 fatigue...

Страница 30: ...solution W m2 0 1 10 3 0 001 0 01 0 1 Spectral range 315nm 400nm Peak 360nm Calibration uncertainty 5 f 1 response according to the cosine law 6 f3 linearity 1 f4 instrument reading error 1digit f5 fa...

Страница 31: ...on W m2 0 1 10 3 0 001 0 01 0 1 Spectral range 280nm 315nm Peak 305nm Calibration uncertainty 5 f 1 response according to the cosine law 6 f3 linearity 2 f4 instrument reading error 1digit f5 fatigue...

Страница 32: ...on W m2 0 1 10 3 0 001 0 01 0 1 Spectral range 220nm 280nm Peak 260nm Calibration uncertainty 5 f 1 response according to the cosine law 6 f3 linearity 1 f4 instrument reading error 1digit f5 fatigue...

Страница 33: ...otted Line Probe Spectral sensitivity LP471 ERY The probe LP 9021 ERY measures the effective total irradiance W m2 eff according to the UV action curve CEI EN 60335 2 27 A particular type of photodiod...

Страница 34: ...ngle 2 Measurement range 0 1 cd m2 2000 103 cd m2 LP 471 PAR Quantum radiometric probe for the measurement of the photon flow across the chlorophyll range PAR Photosynthetically Active Radiation 400nm...

Страница 35: ...SERIAL INTERFACE AND USB 19 STORING AND TRANSFERRING DATA TO A PERSONAL COMPUTER 21 THE LOGGING FUNCTION ONLY FOR HD2102 2 21 CLEARING THE MEMORY ONLY FOR HD2102 2 21 THE PRINT FUNCTION 22 CONNECTION...

Страница 36: ...m d fectueux Dieser Garantieschein muss der Spedition beigelegt werden wenn das Ger t an das Kundendienstzentrum gesandt wird WICHTIG Die Garantie ist nur g ltig wenn dieser Abschnitt bis ins Einzelne...

Отзывы: