3
1.
Input B
, DIN 45326 8-pole connector
2.
Input A
, DIN 45326 8-pole connector
3.
Battery symbol: indicates the battery charge level
4.
First display line (line X)
5.
Third display line (line Z)
6.
Key <
F2
>: activates the central command on the controls bar
7.
Key <
F1
>: activates the left-hand command on the controls bar
8.
Key <
MENU
>: displays the instrument’s functions menu
9.
Key <
ESC/CLR
>: allows you to move about in the menu, passing to the higher level; cancels
the current operation without modifying the instrument parameters. It clears the peak value re-
lated to pressure measurements.
10.
Key <
7/HOLD
>: in the menu it writes the number 7; in normal operation it freezes the meas-
urement.
11.
Key <
5/DATA CALL
>: in the menu it writes the number 5; in normal operation it recalls the
minimum (key <F1>), maximum (key <F2>) and mean (key <F3>) value of the three inputs
12.
Key <
4/S
ERIAL
O
UT
>: in the menu it writes the number 4; in normal operation it activates the
menu for the "Serial output" function
13.
Key <
1/MATH
>: in the menu it writes the number 1; in normal operation it activates the func-
tion that manages mathematical operations
14.
Key <
.
> (decimal point): in the menu it writes the decimal point. When pressed after the
<MENU> key, it switches over the instrument’s Auto Power Off function.
15.
Key <
0
>: in the menu it writes the number zero. In measurement mode, it adjusts the offset of
probes provided with this function.
16.
Key <
LEFT/UP
>: in the menu it shifts the cursor up or to the left, in measurement it increases
the display contrast
17.
RS232C
9-pole connector
18.
External auxiliary power supply connector
19.
Key <
RIGHT/DOWN
>: in the menu it shifts the cursor down or to the right; in measurement it
decreases the display contrast
20.
Key <
ENTER
>: in the menu it accepts the active function. In measurement mode, it provides or
cuts off power supply to the hot-wire probe.
21.
Key <
+/-
>: in the menu it inserts the "-" sign in front of a number. Using the SICRAM module
PP471 for pressure probes TP704 and TP705, it activates and deactivates the relative function.
22.
Key <
3/TIME
>: in the menu it writes the number 3; in normal operation it activates the menu
for the Time function
23.
Key <
2/LOG
>: in the menu it writes the number 2; in normal operation it activates the menu for
the Logging function
24.
Key <
6/RCD
>: in the menu it writes the number 6; in normal operation it activates the menu for
the Record function
25.
Key <
9/UNIT
>: in the menu it writes the number 9; in normal operation activates the menu for
selecting the unit of measurement for the three inputs
26.
Key <
8/REL
>: displays the difference between the current value and the one stored the moment
the key was pressed
27.
Key <
ON/OFF
>: switches the instrument on and off
28.
Key <
F3
>: activates the right-hand command on the controls bar
29.
Controls bar (the indications vary according to the active function)
30.
Second display line (line Y)
31.
Indications of the active functions
32.
Internal temperature indication
33.
Input C
, DIN 45326 8-pole connector
REV. 3.1
June 15
th
2009