Chapter 5 Parameters
|
VFD-S Series
5-30
Revision August 2006, SE08, SW V2.61
2-05
Loss of ACI Signal (4-20mA)
Factory Setting: d0
Settings
d0
Decelerate to 0 Hz
d1
Coast to stop and display “EF”
d2
Continue operation by last frequency command
This parameter is only effective when the Source of Frequency is commanded by a 4 to
20mA signal. The ACI input is considered lost when the ACI signal falls below 2mA.
2-06
Analog Auxiliary Frequency Operation
Factory Setting: d0
Settings
d0
Disable
d1
AVI (0~10V)
d2
ACI (4~20mA)
This parameter is used to determinate that the analog signal to overlap is 0~10V (AVI) or
4~20mA (ACI).
To make sure the short PIN of J1 on the panel is correct position before setting this parameter.