Revision August 2006, SE08, SW V2.61
Appendix A Specifications
Voltage Class
115V Class
230V Class
460V Class
Model Number VFD-XXXS
002
004
007
002
004
007 015
022
004
007
015
022
Max. Applicable Motor Output (kW)
0.2
0.4 0.75
0.2
0.4 0.75 1.5
2.2
0.4 0.75
1.5
2.2
Max.
Applicable
Motor
Output
(HP) 0.25
0.5 1.0 0.25
0.5 1.0 2.0 3.0 0.5 1.0 2.0 3.0
Rated
Output
Capacity
(KVA) 0.6 1.0 1.6 0.6 1.0 1.6 2.9 4.2 1.2 2.0 3.3 4.4
Rated
Output
Current
(A)
1.6 2.5 4.2 1.6 2.5 4.2 7.5 11.0
1.5 2.5 4.2 5.5
Maximum Output Voltage (V)
3-phase
Proportional to
Twice the Input
Voltage
3-phase Proportional to Input Voltage
Output Rating
Rated Frequency (Hz)
1.0 to 400 Hz
Single phase
Single/3-phase model drive
3-phase
Rated Input Current (A)
6 9 18
4.9/
1.9
6.5/
2.7
9.7/
5.1
15.7/
9.0
24/
15
1.7 2.9 5.1 6.9
Input Current for 1-phase model
drive to be used as 3-phase
model drive
--
--
1.6 3.0 5.1 8.4 --
--
--
Rated Voltage/Frequency
100/110/120 VAC
50/60 Hz
200/208/220/240 VAC
50/60Hz
380/400/415/480 VAC
50/60Hz
Input R
a
ti
ng
Voltage/Freq. Tolerance
Voltage:
±
10%, Frequency:
±
5%
Control System
SPWM (Sinusoidal Pulse Width Modulation, carrier frequency 3k-10kHz)
Output Frequency Resolution
0.1Hz
Torque Characteristics
Including the auto-torque, auto-slip compensation; starting torque can be
150% at 5Hz
Overload Endurance
150% of rated current for 1 minute
Accel/Decel Time
0.1to 600 second (2 Independent settings for Accel/Decel Time)
V/F Pattern
V/F pattern adjustable
C
ontr
ol
C
har
acter
isti
cs
Stall Prevention Level
20 to 250%, Setting of Rated Current
Keypad
Setting by
or Potentiometer
Frequency
Setting
External
Signal
Potentiometer-5K
Ω
/0.5W, DC 0 to +10V or 0 to +5V (Input impedance
47K
Ω
), RS-485 interface, 4 to 20mA (Input impedance 250
Ω
); Multi-
Function Inputs 1 to 5 (7 steps, Jog, up/down)
Keypad
Setting by RUN, STOP
Operation
Setting Signal
External
Signal
M0 to M5 can be combined to offer various modes of operation, RS-485
serial interface (MODBUS).
Multi-Function Input Signal
Multi-step selection 0 to7, Jog, accel/decel inhibit, first/second accel/decel
switch, counter, 8-step PLC operation, external Base Block (NC, NO),
increase/decrease Master Frequency
Multi-Function Output Indication
AC Drive Operating, Frequency Attained, Non-zero, Base Block, Fault
Indication, Local/Remote indication, PLC Operation indication.
Oper
ati
n
g C
h
ar
acter
isti
cs
Analog Output Signal
Analog frequency/current signal output.
Other Function
AVR, S-Curve, Over-Voltage/Over-Current Stall Prevention, Fault Records,
Adjustable Carrier Frequency, DC Braking, Start Frequency for DC Braking,
Momentary Power Loss restart, Frequency Limits, Parameter Lock/Reset,
PID Feedback Control, Reverse Inhibition, etc.
Built-in EMI Filter
VFD002S21E, VFD004S21E, VFD004S43E, VFD007S21E, VFD007S43E,
VFD015S21E, VFD015S43E, VFD022S21E, VFD022S43E
Protection
Self-testing, Over Voltage, Over Current, Under Voltage, Overload,
Overheating, External Fault, Electronic thermal, Ground Fault.
Cooling
Forced air-cooling (
ONLY FOR
022S2XA/B
;
XXXS43A/B/E 1HP~3HP
;
XXXSXXD
;
XXXS21E 400W~3HP). Others are Natural air-cooling.